MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual
__________________________________________________________________
•Press the RUN key, and check the fan or pump direction of rotation. If the direction is not correct, press the STOP key and wait until the fan or pump has come to a complete STOP. Next, power down the inverter.
Danger
After the power has been turned OFF, wait at least 5 minutes until the charge indicator extinguishes completely before touching any wiring, circuit boards or components.
•Reverse any two of the fan or pump motor connections at the inverter ( U(T1),V(T2), or W(T3) ). Next, following STEP 2,
Step 5 – Making External Digital Input/Output and Analog Feedback Control wiring Connections
•Before removing any covers or making any external control connections, power down the inverter.
Danger
After the power has been turned OFF, wait at least 5 minutes until the charge indicator extinguishes completely before touching any wiring, circuit boards, or components.
________________________________________________________________ 4