2-5. Shielding Gas Connection To Regulator/Flowmeter
6
5
4
Tools Needed:
1-1/8, 5/8 in
Obtain gas cylinder and chain to running gear, wall, or other stationary support so cylinder cannot fall and break off valve.
1Cap
2Cylinder Valve
Remove cap, stand to side of valve, and open valve slightly. Gas flow blows dust and dirt from valve. Close valve.
3Cylinder
4Regulator/Flowmeter
1
2
3
OR
Argon Gas
7 8
CO2 Gas
Install so face is vertical.
5 Gas Hose Connection
Fitting has
6 Flow Adjust
Typical flow rate is 20 cfh (cubic feet per hour). Check wire manufacturer’s recommended flow rate.
1
2
3
ssb3.1 5/94 –
Make sure flow adjust is closed when opening cylinder to avoid damage to the flowmeter.
7CO2 Adapter
8
Install adapter with
Obtain gas cylinder and chain to running gear, wall, or other stationary support so cylinder cannot fall and break off valve.
2-6. Shielding Gas Connections To Gas Control
1
2
Tools Needed:
1 Gas Control
2 Shielding Gas Valve Fitting
To Gun
| From Regulator/ | |
5/8 in | Flowmeter | |
|