Multi-Tech Systems MT5634ZBA-VV.90, MT5634ZBAV.90, MT5634ZBAV.92 Operation, About the Front Panel

Page 15

Chapter 3 - Operation

Chapter 3 - Operation

About the Front Panel

The MultiModem V.92 Front Panel

The MultiModem V.90 Front Panel

The MultiModemZBA LED indicators on the front panel indicate status, configuration, and activity:

TD – Transmit Data. Flashes when the modem is transmitting data to another modem. RD – Receive Data. Flashes when the modem is receiving data.

CD – Carrier Detect. Lights when the modem detects a valid carrier signal from another modem. It is on when the modem is communicating with the other modem, and off when the link is broken.

56 – 56K Mode (56,000–28,000 bps). Lights whenever the modem is set for or connects using the V.90 or V.92 protocol. The actual connection speed depends on ISP server capabilities and line conditions.

33 – V.34 Mode (33,600–16,800 bps). Lights whenever the modem connects using the V.34 protocol.

14 – V.32bis Mode (14,400–12,000 bps). Lights when the modem connects using the V.32bis protocol. The modem can connect at lower than V.32bis speeds, but no speed indicator lights during the connection.

OH – Off-Hook.Lights when the modem is off-hook, which occurs when the modem is dialing, online, or answering a call. Flashes when the modem pulse-dials.

TR – Terminal Ready. Lights when a communications program is using the modem. It means the modem is ready for an outgoing or incoming call. It goes off when the communications program disconnects the serial port. When it goes off, a connected modem will also disconnect.

EC – Error Correction (V.42). Lights continuously when the modem is in V.42 error correction mode, and flashes when compression is activated.

FX – Fax. Lights when the modem is in fax mode.

Note: When you turn on the modem, the protocol indicators flash briefly as the modem does a self-test, after which the 56 indicator lights. After a call, the indicator for the protocol used in the connection remains lit until another call is made or the modem is reset. If you connect at a rate under 14,400 bps, all protocol indicators remain off after the connection is broken, even though the modem is still turned on.

Multi-Tech Systems, Inc. MT5634ZBA-Series User Guide

15

Image 15
Contents MultiModemZBA Global MT5634ZBA-Series MultiModemZBA Global MT5634ZBA-Series User Guide Table of Contents Index Features IntroductionProducts Features Products Features TableWhat Is in Your Modem Package Change the Internal Jumpers InstallationSafety Warnings Mount the FeetLocation of the Jumpers Changing the Dial-Up/Leased-Line JumperChanging the Voice Jumper Connect the Modem to the Telephone Line Connect the Two-Wire Leased Line Leased Line OnlyConnect the Modem to Your PC Connect the Modem to Your PCConnect Speakers Voice Option Connect the Modem to the AC Power OutletPower-On Test Connect a Microphone Voice OptionInstall the Modem Driver Installing the Modem DriverRemoving an Old Modem Driver Configure the Modem for Your Country Using the Global Wizard to Configure Your ModemUsing AT Commands to Configure Your Modem Modem-on-Hold Install Data Communications SoftwareAbout the Front Panel OperationOperation PhoneTools FeaturesSetup Leased-Line OperationConnecting to the Internet AT Commands, S- Registers, and Result Codes Changing the Setup Password Remote ConfigurationBasic Procedure SetupChanging the Setup Password Callback SecurityTurning Callback Security On and Off Assigning Callback Passwords and Phone Numbers Setting Callback Security Message ParityCalling Procedures Password-Only CallbackNumber-Entry Callback Callback Security Commands Extension-Entry CallbackDirect Connection Callback Assignments Form Troubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When Dialing Page Modem Disconnects While Online There Are Garbage Characters on the Monitor Modem Cannot Connect When AnsweringFile Transfer Is Slower Than It Should Be Data Is Being LostFax and Data Software Can’t Run at the Same Time Modem Doesn’t Work with Caller IDFax Data Rates Appendix a Technical SpecificationsTransmit Level Identify the Current Firmware Version Upgrade OverviewAppendix B Upgrading Modem’s Firmware Identify the Modem FirmwareRestore Your Parameters Download the Upgrade FileExtract the Upgrade Files Upgrade the Modem’s FirmwareFCC Part 15 Regulation Appendix C Regulatory ComplianceFCC Part 68 Telecom Canadian Limitations Notice Fax Branding StatementInternational Modem Restrictions EMC, Safety and R&TTE Directive ComplianceSouth African Statement New Zealand Telecom Warning NoticeSetup Appendix D Installing a Modem Under LinuxConnecting to a Cisco Router Console Port Appendix E Connecting to a Cisco RouterConsole Port Connections Remote ConfigurationAppendix F Warranty, Service, and Technical Support WarrantyRepair Procedures for U.S. and Canadian Customers Online Warranty Registration Service Repair Procedures for International DistributorsReplacement Parts Technical Support Index Index