Multi-Tech Systems MT5600BA-V92 Country/Region of Installation, Command +MS= Modulation Selection

Page 14

 

 

 

 

 

Chapter 2 – AT Commands

Command:

+GCI

Country/Region of Installation

Description:

 

This extended syntax command selects and indicates the region/country of installation for

 

 

the modem. The parameter selects the settings for any operational parameters that need

 

 

to be adjusted for national regulations or telephone networks.

 

 

Syntax: +GCI=<region_code>Defined Values: <region_code>Example: Euro/Nam = B5.

 

 

For a list of regions/countries approvals and codes, see the Multi-Tech Web site at:

 

 

http://www.multitech.com/PRODUCTS/Info/approvals

Default:

 

If the modem is specified for use in only one country, the country code is the default.

 

 

Otherwise, the default is defined by the OEM. The factory default is B5.

Report Commands:

+GCI?

Reports current or selected values.

 

 

+GCI=?

Reports supported range of parameter values.

Command:

+MS= Modulation Selection

 

Values & Default:

See description.

 

 

Description:

 

This extended-format command selects modulation and, optionally, enables or disables

 

 

automode, specifies the lowest and highest connection rates, selects µ-Law or A-Law

 

 

codec type, and specifies the highest transmit rate using one to five subparameters.

 

 

The command format is:

 

 

 

+MS=[+MS=[<carrier>[,<automode>[,<min_TX_rate>[,<max_TX_rate>[,min_RX_rate>[,<max_RX_rate>]]]]]]

 

 

Subparameters that are not entered retain their current value. Commas separate optional

 

 

subparameters and should be inserted to skip a subparameter. Example: +MS=,0,<CR>

 

 

disables automode and keeps all other settings at their current values.

Subparameters:

 

mod A decimal number that specifies the preferred modulation (automode enabled) or

 

 

the modulation to use in originating or answering a connection (auto-mode disabled).

 

 

+MS Command Supported Rates

 

 

Modulation

<carrier>

Possible (<min_rx_rate>,<max_rx_rate>,(<min_tx_rate>), and

 

 

 

 

 

<max_tx_rate>) Rates (bps)

 

 

Bell 103

B103

300

 

 

Bell 212

B212

1200 Rx/75 Tx or 75 Rx/1200 Tx

 

 

V.21

 

V21

300

 

 

V.22

 

V22

1200

 

 

V.22 bis

V22B

2400 or 1200

 

 

V.23

 

V23C

1200

 

 

V.32

 

V32

9600 or 4800

 

 

V.32 bis

V32B

14400, 12000, 9600, 7200, or 4800

 

 

V.34

 

V34

33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 14400,

 

 

 

 

 

12000, 9600, 7200, 4800, or 2400

 

 

V.90

 

V90

56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667, 45333,

 

 

 

 

 

44000, 42667, 41333, 40000, 38667, 37333, 36000, 34667, 33333,

 

 

V.92 downstream V92

32000, 30667, 29333, 28000

 

 

same as V.90 above

 

 

V.92 upstream

V92

48000, 46667, 45333, 44000, 42667, 41333, 40000, 38667, 37333,

 

 

 

 

 

36000, 34667, 33333, 32000, 30667, 29333, 28000, 26667, 25333,

24000

Note: Some <carrier> values may not be supported by certain model models.

automode An optional numeric value that enables or disables automatic modulation negotiation using V.8bis/V.8 or V.32bis Annex A. The options are:

0 = Disables automode

1 = Enables automode (default)

<min_rx_rate> and <max_rx_rate>

Numeric values which specify the lowest (<min_rx_rate>) and highest

(<max_rx_rate>) rate at which the modem may establish a receive connection. May be used to condition distinct limits for the receive direction as distinct from the transmit direction. Values for this subparameter are decimal encoded, in units of bit/s. The possible values for each modulation are listed in the table above. Actual values will be limited to possible values corresponding to the entered <carrier> and fall-back <carrier> as determined during operation. (Default = lowest (<min_rx_rate>) and highest (<max_rx_rate>) rate supported by the selected carrier.)

<min_tx_rate> and <max_tx_rate>

Numeric values which specify the lowest (<min_tx_rate>) and highest

(<max_tx_rate>) rate at which the modem may establish a transmit connection. Non- zero values for this subparameter are decimal encoded, in units of bit/s. The possible values for each modulation are listed in the table above. Actual values will be limited to possible values corresponding to the entered <carrier> and fall-back <carrier> as determined during operation. (Default = lowest (<min_tx_rate>) and highest (<max_tx_rate>) rate supported by the selected carrier.)

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

14

Image 14
Contents MultiModem→ Record of Revisions WarrantyCopyright TrademarksTable of Contents You must press Enter to send the command to the modem IntroductionAT Commands General CommandsCommand Hook Control Command DS=n Dial Stored Telephone NumberCommand En Echo Command Mode Characters Command Information RequestCommand Tone Dialing Command Result Codes Enable/DisableCommand ? Read Register Value Command Result Code FormatCommand Data Carrier Detect DCD Control Command Long Space DisconnectCommand Modem Reset Command Dn Data Terminal Ready DTR ControlCommand Load Factory Settings Command Modem-Initiated Flow ControlCommand V.42bis Data Compression Command V.22bis Guard Tone ControlCommand Clear to Send CTS Control Command Make/Break Dial RatioCommand Sync/Async Mode Command Data Set Ready DSR ControlCommand Select Profile for Hard Reset Command Store Current ConfigurationCommand &Xn Synchronous Clock Source Command &Zn=x Store Telephone NumberCommand Line Signal Quality Command %En Line Quality MonitorCommand Line Signal Level Command PCM Code SelectionCommand \Vn Single Line Connect Message Command \Kn Break ControlCommand \Nn Error Correction Mode Selection Report CommandsValues & Default Country/Region of InstallationCommand +MS= Modulation Selection SubparametersCommand View Numbers in Blacklist Command MNP Extended ServicesCommand Flash Memory Download Command View Delayed NumbersCommand *E Escape Remote Configuration Escape CommandsCommand +++ Escape Sequence Command +PIG=n PCM Upstream Ignore Modem Connection CommandsCommand +PCW=n Call Waiting Enable Command +PQC=n Quick Connect ControlResult Code Force Full Startup Procedure Next ConnectionEnable Quick Connect Profile Save Caller ID Commands Callback Security CommandsCommand +DS Data Compression Data Compression CommandsCommand +DR Data Compression Reporting Command +DS44 V.44 Compression SelectCommand +EFCS Bit Frame Check Sequence Error Control CommandsCommand +EB Break Handling in Error Control Operation Command +ER Error Control Reporting+ESR? Command +ESR Selective RejectCommand +ETBM Call Termination Buffer Management Command +ILRR DTE-Modem Local Rate Reporting DTE CommandsCommand +IFC DTE-Modem Local Flow Control Reported RateCommand +MR Modulation Reporting Control Modulation CommandCommand +IPR Fixed DTE Rate +MCR Report SyntaxBehavior in Data Mode +FCLASS=0 Call Control CommandCommand -STE= Set Telephony Extension Behavior in Voice Mode +FCLASS=8Examples No Carrier ATS86? Test CommandCommand &T n Test Command Configuration Commands Voice CommandsVoice Commands Overview Command +FCLASS=8 Select Voice ModeCommand +VNH= Automatic Hang-up Control Command +FLO Flow ControlCommand +VRX Start Modem Receive Record Voice CommandsCommand +VIP Voice Initialize All Parameters Command +VTS Send Voice TonesCommand +VGT Voice Gain Transmit Playback Volume Command +VTX Start Modem Transmit PlaybackCommand +VGR Voice Gain Receive Record Gain +VTS Examples+VLS Example Command +VIT Voice Inactivity Timer DTE/ModemCommand +VLS Analog Source/Destination Selection +VSP=1 Command +VRA Ringback Goes Away TimerTable of +VLS Command Options Label Primitives Description IntervalCommand +VSM Compression Method Selection Command +VRN Ringback Never Appeared TimerCommand +VSD Silence Detection Quiet and Silence Command +VDT Control Tone Cadence Reporting Command +VTD Beep Tone Duration TimerCommand +VDR Distinctive Ring Before using it DescriptionRate +VPR?Command +VGM Microphone Gain Speakerphone CommandsCommand +VSP Speakerphone ON/OFF Command +VGS Speaker GainShielded Hex Event Report Description Code Voice Mode Shielded CodesUnformatted Form Reporting Caller ID Event Number 4 Extended Keypad Dtmf a Command +A8I CI Signal Indication V.8bis CommandsCommand +A8E V.8bis Operation Controls Default Values25bis Commands List Identification Number 25bis ResponsesList Request of Forbidden Number List Request of Stored NumberRegisters Reg Unit Range Default DescriptionRegisters Registers +MR, +ER,+DR, and W commands Result Codes FAX Data+ER None +DR ALT+DR None +ER LapmTerse Verbose Description Terse Verbose Description Setting Country/Regional Codes ExampleIndex Qcpc 46, 47, 48, 49 Index
Related manuals
Manual 57 pages 24.51 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.