Multi-Tech Systems MT5600BA-V92 manual Terse Verbose Description

Page 50

Chapter 7 – Result Codes

Terse Verbose

Description

196+MRR: 29333 Connected at 29333 bps. Modem connects to the line at 29333 bps and carrier reporting is enabled. (See S95, Xn)

197+MRR: 30667 Connected at 30667 bps. Modem connects to the line at 30667 bps and carrier reporting is enabled. ((See S95, Xn)

198+MRR: 33333 Connected at 33333 bps. Modem connects to the line at 33333 bps and carrier reporting is enabled. (See S95, Xn)

199+MRR: 34667 Connected at 34667 bps. Modem connects to the line at 34667 bps and carrier reporting is enabled. (See S95, Xn)

200+MRR: 37333 Connected at 37333 bps. Modem connects to the line at 37333 bps and carrier reporting is enabled. (See S95, Xn)

201+MRR: 38667 Connected at 38667 bps. Modem connects to the line at 38667 bps and carrier reporting is enabled. (See S95, Xn)

202+MRR: 41333 Connected at 41333 bps. Modem connects to the line at 41333 bps and carrier reporting is enabled. (See S95, Xn)

203+MRR: 42667 Connected at 42667 bps. Modem connects to the line at 42667 bps and carrier reporting is enabled. (See S95, Xn)

204+MRR: 45333 Connected at 45333 bps. Modem connects to the line at 45333 bps and carrier reporting is enabled. (See S95, Xn)

205+MRR: 46667 Connected at 46667 bps. Modem connects to the line at 46667 bps and carrier reporting is enabled. (See S95, Xn)

206+MRR: 49333 Connected at 49333 bps. Modem connects to the line at 49333 bps and carrier reporting is enabled. (See S95, Xn)

207+MRR: 50667 Connected at 50667 bps. Modem connects to the line at 50667 bps and carrier reporting is enabled. (See S95, Xn)

208+MRR: 53333 Connected at 53333 bps. Modem connects to the line at 53333 bps and carrier reporting is enabled. (See S95, Xn)

209+MRR: 54667 Connected at 54667 bps. The modem has connected to the line at 54667 bps and carrier reporting is enabled. (See S95, Xn)

Notes:

1.See Vn for result code selection; i.e., short form (result code) or verbose/extended (result message).

2.See Wn for extended connect message control.

3.See S95 for extended result code enabling options (which override some Wn commands).

4.See Xn for extended result code subset enabling options.

5.See \Vn for single line connect message enable options.

6.See +MR for modulation reporting control.

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

50

Image 50
Contents MultiModem→ Record of Revisions WarrantyCopyright TrademarksTable of Contents You must press Enter to send the command to the modem IntroductionAT Commands General CommandsCommand Hook Control Command DS=n Dial Stored Telephone NumberCommand En Echo Command Mode Characters Command Information RequestCommand Tone Dialing Command Result Codes Enable/DisableCommand ? Read Register Value Command Result Code FormatCommand Data Carrier Detect DCD Control Command Long Space DisconnectCommand Modem Reset Command Dn Data Terminal Ready DTR ControlCommand Load Factory Settings Command Modem-Initiated Flow ControlCommand V.42bis Data Compression Command V.22bis Guard Tone ControlCommand Clear to Send CTS Control Command Make/Break Dial RatioCommand Sync/Async Mode Command Data Set Ready DSR ControlCommand Select Profile for Hard Reset Command Store Current ConfigurationCommand &Xn Synchronous Clock Source Command &Zn=x Store Telephone NumberCommand Line Signal Quality Command %En Line Quality MonitorCommand Line Signal Level Command PCM Code SelectionCommand \Vn Single Line Connect Message Command \Kn Break ControlCommand \Nn Error Correction Mode Selection Report CommandsValues & Default Country/Region of InstallationCommand +MS= Modulation Selection SubparametersCommand View Numbers in Blacklist Command MNP Extended ServicesCommand Flash Memory Download Command View Delayed NumbersCommand *E Escape Remote Configuration Escape CommandsCommand +++ Escape Sequence Command +PIG=n PCM Upstream Ignore Modem Connection CommandsCommand +PCW=n Call Waiting Enable Command +PQC=n Quick Connect ControlResult Code Force Full Startup Procedure Next ConnectionEnable Quick Connect Profile Save Caller ID Commands Callback Security CommandsCommand +DS Data Compression Data Compression CommandsCommand +DR Data Compression Reporting Command +DS44 V.44 Compression SelectCommand +EFCS Bit Frame Check Sequence Error Control CommandsCommand +EB Break Handling in Error Control Operation Command +ER Error Control Reporting+ESR? Command +ESR Selective RejectCommand +ETBM Call Termination Buffer Management Command +ILRR DTE-Modem Local Rate Reporting DTE CommandsCommand +IFC DTE-Modem Local Flow Control Reported RateCommand +MR Modulation Reporting Control Modulation CommandCommand +IPR Fixed DTE Rate +MCR Report SyntaxBehavior in Data Mode +FCLASS=0 Call Control CommandCommand -STE= Set Telephony Extension Behavior in Voice Mode +FCLASS=8Examples No Carrier ATS86? Test CommandCommand &T n Test Command Configuration Commands Voice CommandsVoice Commands Overview Command +FCLASS=8 Select Voice ModeCommand +VNH= Automatic Hang-up Control Command +FLO Flow ControlCommand +VRX Start Modem Receive Record Voice CommandsCommand +VIP Voice Initialize All Parameters Command +VTS Send Voice TonesCommand +VGT Voice Gain Transmit Playback Volume Command +VTX Start Modem Transmit PlaybackCommand +VGR Voice Gain Receive Record Gain +VTS Examples+VLS Example Command +VIT Voice Inactivity Timer DTE/ModemCommand +VLS Analog Source/Destination Selection +VSP=1 Command +VRA Ringback Goes Away TimerTable of +VLS Command Options Label Primitives Description IntervalCommand +VSM Compression Method Selection Command +VRN Ringback Never Appeared TimerCommand +VSD Silence Detection Quiet and Silence Command +VDT Control Tone Cadence Reporting Command +VTD Beep Tone Duration TimerCommand +VDR Distinctive Ring Before using it DescriptionRate +VPR?Command +VGM Microphone Gain Speakerphone CommandsCommand +VSP Speakerphone ON/OFF Command +VGS Speaker GainShielded Hex Event Report Description Code Voice Mode Shielded CodesUnformatted Form Reporting Caller ID Event Number 4 Extended Keypad Dtmf a Command +A8I CI Signal Indication V.8bis CommandsCommand +A8E V.8bis Operation Controls Default Values25bis Commands List Identification Number 25bis ResponsesList Request of Forbidden Number List Request of Stored NumberRegisters Reg Unit Range Default DescriptionRegisters Registers +MR, +ER,+DR, and W commands Result Codes FAX Data+ER None +DR ALT+DR None +ER LapmTerse Verbose Description Terse Verbose Description Setting Country/Regional Codes ExampleIndex Qcpc 46, 47, 48, 49 Index
Related manuals
Manual 57 pages 24.51 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.