Multi-Tech Systems MT5600BA-V92 manual Escape Commands, Command +++ Escape Sequence

Page 16

Chapter 2 – AT Commands

Escape Commands

Command: +++

Escape Sequence

 

Note: Use with MT5600BA and MT5600BR only.

 

Type +++ and wait for OK response.

 

Then issue the following command by typing AT <CR>. (<CR> indicates that you must

 

click Enter).

Values:

n/a

Description:

Puts the modem in online command mode.

Command: *E

Escape Remote Configuration

 

Note: Use with MT5600BA and MT5600BR only.

Values:

n/a

Description:

Escape Remote Configure Sequence. The remote modem configuration escape command

 

is defined in S-Register S13.

 

Notes: The Escape Remote Configuation command (*E) must be issued while online

 

with the remote modem.

 

Remote Configuration is initiated by using the command: ***

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

16

Image 16
Contents MultiModem→ Warranty CopyrightRecord of Revisions TrademarksTable of Contents You must press Enter to send the command to the modem IntroductionAT Commands General CommandsCommand DS=n Dial Stored Telephone Number Command En Echo Command Mode CharactersCommand Hook Control Command Information RequestCommand Result Codes Enable/Disable Command ? Read Register ValueCommand Tone Dialing Command Result Code FormatCommand Long Space Disconnect Command Modem ResetCommand Data Carrier Detect DCD Control Command Dn Data Terminal Ready DTR ControlCommand Modem-Initiated Flow Control Command V.42bis Data CompressionCommand Load Factory Settings Command V.22bis Guard Tone ControlCommand Make/Break Dial Ratio Command Sync/Async ModeCommand Clear to Send CTS Control Command Data Set Ready DSR ControlCommand Store Current Configuration Command &Xn Synchronous Clock SourceCommand Select Profile for Hard Reset Command &Zn=x Store Telephone NumberCommand %En Line Quality Monitor Command Line Signal LevelCommand Line Signal Quality Command PCM Code SelectionCommand \Kn Break Control Command \Nn Error Correction Mode SelectionCommand \Vn Single Line Connect Message Report CommandsCountry/Region of Installation Command +MS= Modulation SelectionValues & Default SubparametersCommand MNP Extended Services Command Flash Memory DownloadCommand View Numbers in Blacklist Command View Delayed NumbersCommand +++ Escape Sequence Escape CommandsCommand *E Escape Remote Configuration Modem Connection Commands Command +PCW=n Call Waiting EnableCommand +PIG=n PCM Upstream Ignore Command +PQC=n Quick Connect ControlEnable Quick Connect Profile Save Force Full Startup Procedure Next ConnectionResult Code Caller ID Commands Callback Security CommandsData Compression Commands Command +DR Data Compression ReportingCommand +DS Data Compression Command +DS44 V.44 Compression SelectError Control Commands Command +EB Break Handling in Error Control OperationCommand +EFCS Bit Frame Check Sequence Command +ER Error Control ReportingCommand +ETBM Call Termination Buffer Management Command +ESR Selective Reject+ESR? DTE Commands Command +IFC DTE-Modem Local Flow ControlCommand +ILRR DTE-Modem Local Rate Reporting Reported RateModulation Command Command +IPR Fixed DTE RateCommand +MR Modulation Reporting Control +MCR Report SyntaxCall Control Command Command -STE= Set Telephony ExtensionBehavior in Data Mode +FCLASS=0 Behavior in Voice Mode +FCLASS=8Examples Command &T n Test Command Test CommandNo Carrier ATS86? Voice Commands Voice Commands OverviewConfiguration Commands Command +FCLASS=8 Select Voice ModeCommand +VNH= Automatic Hang-up Control Command +FLO Flow ControlVoice Commands Command +VIP Voice Initialize All ParametersCommand +VRX Start Modem Receive Record Command +VTS Send Voice TonesCommand +VTX Start Modem Transmit Playback Command +VGR Voice Gain Receive Record GainCommand +VGT Voice Gain Transmit Playback Volume +VTS ExamplesCommand +VLS Analog Source/Destination Selection Command +VIT Voice Inactivity Timer DTE/Modem+VLS Example Command +VRA Ringback Goes Away Timer Table of +VLS Command Options Label Primitives Description+VSP=1 IntervalCommand +VSD Silence Detection Quiet and Silence Command +VRN Ringback Never Appeared TimerCommand +VSM Compression Method Selection Command +VTD Beep Tone Duration Timer Command +VDR Distinctive RingCommand +VDT Control Tone Cadence Reporting Before using it DescriptionRate +VPR?Speakerphone Commands Command +VSP Speakerphone ON/OFFCommand +VGM Microphone Gain Command +VGS Speaker GainUnformatted Form Reporting Caller ID Voice Mode Shielded CodesShielded Hex Event Report Description Code Event Number 4 Extended Keypad Dtmf a V.8bis Commands Command +A8E V.8bis Operation ControlsCommand +A8I CI Signal Indication Default Values25bis Commands 25bis Responses List Request of Forbidden NumberList Identification Number List Request of Stored NumberRegisters Reg Unit Range Default DescriptionRegisters Registers +MR, +ER,+DR, and W commands Result Codes FAX Data+DR ALT +DR None+ER None +ER LapmTerse Verbose Description Terse Verbose Description Setting Country/Regional Codes ExampleIndex Qcpc 46, 47, 48, 49 Index
Related manuals
Manual 57 pages 24.51 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.