Multi-Tech Systems MT5600BA-V92 manual DTE Commands, Command +IFC DTE-Modem Local Flow Control

Page 23

Chapter 2 – AT Commands

DTE Commands

Command: +IFC DTE-Modem Local Flow Control

Description:This extended-format compound parameter controls the operation of local flow control between the DTE and the modem during the data state when V.42 error control is used or when fallback to non-error control mode is specified to include buffering and flow control. It accepts two numeric subparameters.

Syntax: +IFC=[<modem_by_DTE>[,<DTE_by_modem>]]

Values:<modem_by_DTE> Specifies method DTE will use to control flow of received data from the modem.

0None.

1XON/XOFF on transmitted data; do not pass XON/XOFF characters to remote modem.

2Circuit 133 (RR). Default

3DC1/DC3 on circuit 103 (TD) with DC1/DC3 characters

being passed through to the remote DCE in addition to being acted upon for local flow control.

<DTE_by_modem> Specifies method modem will use to control flow of transmitted data from the DTE.

0None.

1XON/XOFF on received data.

2CTS/RTS. Default

Report Commands: +IFC? Reports current or selected values.

+IFC=? Reports supported range of parameter values.

Command: +ILRR

DTE-Modem Local Rate Reporting

Description:

This extended-format numeric parameter controls whether or not the +ILRR:<rate>

 

information text is transmitted from the modem to the DTE.

 

Syntax: +ILRR=<value>

Values:

<value> Decimal number corresponding to the selected option.

 

 

0 Disables reporting of local port rate (+ILRR: is not transmitted). Default

 

 

1 Enables reporting of local port rate (+ILRR: is transmitted).

Report Commands:

+ILRR?

Reports current or selected values.

 

+ILRR=? Reports supported range of parameter values.

Reported Rate:

The <rate> reported is the current (negotiated or renegotiated) DTE-modem rate. If

 

enabled, intermediate result code is transmitted after any modulation, error control or data

 

compression reports are transmitted and before any final result code is transmitted. The

 

<rate> is applied after the final result code is transmitted. The DTE-modem port rate

 

changes only if neither buffered mode nor error controlled means are enabled (+ES=x,0)

 

and if the negotiated carrier rate (+MRR) does not match the current DTE-modem port

 

rate (auto detected from previous command line).

 

Syntax: +ILRR: <rate>[,<rx_rate>].

 

Reported Rate Values:

 

<rate>

Decimal value representing the current (negotiated or renegotiated)

 

 

DTE-modem rate: 0, 300, 1200, 2400, 4800, 9600, 19200, 38400,

57600, 115200, 230400

<rx_rate> Optional decimal value reporting the RXD rate, if it is different from the TXD rate: 0,300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, or 230400

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

23

Image 23
Contents MultiModem→ Trademarks WarrantyCopyright Record of RevisionsTable of Contents Introduction You must press Enter to send the command to the modemGeneral Commands AT CommandsCommand Information Request Command DS=n Dial Stored Telephone NumberCommand En Echo Command Mode Characters Command Hook ControlCommand Result Code Format Command Result Codes Enable/DisableCommand ? Read Register Value Command Tone DialingCommand Dn Data Terminal Ready DTR Control Command Long Space DisconnectCommand Modem Reset Command Data Carrier Detect DCD ControlCommand V.22bis Guard Tone Control Command Modem-Initiated Flow ControlCommand V.42bis Data Compression Command Load Factory SettingsCommand Data Set Ready DSR Control Command Make/Break Dial RatioCommand Sync/Async Mode Command Clear to Send CTS ControlCommand &Zn=x Store Telephone Number Command Store Current ConfigurationCommand &Xn Synchronous Clock Source Command Select Profile for Hard ResetCommand PCM Code Selection Command %En Line Quality MonitorCommand Line Signal Level Command Line Signal QualityReport Commands Command \Kn Break ControlCommand \Nn Error Correction Mode Selection Command \Vn Single Line Connect MessageSubparameters Country/Region of InstallationCommand +MS= Modulation Selection Values & DefaultCommand View Delayed Numbers Command MNP Extended ServicesCommand Flash Memory Download Command View Numbers in BlacklistCommand *E Escape Remote Configuration Escape CommandsCommand +++ Escape Sequence Command +PQC=n Quick Connect Control Modem Connection CommandsCommand +PCW=n Call Waiting Enable Command +PIG=n PCM Upstream IgnoreResult Code Force Full Startup Procedure Next ConnectionEnable Quick Connect Profile Save Callback Security Commands Caller ID CommandsCommand +DS44 V.44 Compression Select Data Compression CommandsCommand +DR Data Compression Reporting Command +DS Data CompressionCommand +ER Error Control Reporting Error Control CommandsCommand +EB Break Handling in Error Control Operation Command +EFCS Bit Frame Check Sequence+ESR? Command +ESR Selective RejectCommand +ETBM Call Termination Buffer Management Reported Rate DTE CommandsCommand +IFC DTE-Modem Local Flow Control Command +ILRR DTE-Modem Local Rate Reporting+MCR Report Syntax Modulation CommandCommand +IPR Fixed DTE Rate Command +MR Modulation Reporting ControlBehavior in Voice Mode +FCLASS=8 Call Control CommandCommand -STE= Set Telephony Extension Behavior in Data Mode +FCLASS=0Examples No Carrier ATS86? Test CommandCommand &T n Test Command Command +FCLASS=8 Select Voice Mode Voice CommandsVoice Commands Overview Configuration CommandsCommand +FLO Flow Control Command +VNH= Automatic Hang-up ControlCommand +VTS Send Voice Tones Voice CommandsCommand +VIP Voice Initialize All Parameters Command +VRX Start Modem Receive Record+VTS Examples Command +VTX Start Modem Transmit PlaybackCommand +VGR Voice Gain Receive Record Gain Command +VGT Voice Gain Transmit Playback Volume+VLS Example Command +VIT Voice Inactivity Timer DTE/ModemCommand +VLS Analog Source/Destination Selection Interval Command +VRA Ringback Goes Away TimerTable of +VLS Command Options Label Primitives Description +VSP=1Command +VSM Compression Method Selection Command +VRN Ringback Never Appeared TimerCommand +VSD Silence Detection Quiet and Silence Before using it Description Command +VTD Beep Tone Duration TimerCommand +VDR Distinctive Ring Command +VDT Control Tone Cadence Reporting+VPR? RateCommand +VGS Speaker Gain Speakerphone CommandsCommand +VSP Speakerphone ON/OFF Command +VGM Microphone GainShielded Hex Event Report Description Code Voice Mode Shielded CodesUnformatted Form Reporting Caller ID Event Number 4 Extended Keypad Dtmf a Default Values V.8bis CommandsCommand +A8E V.8bis Operation Controls Command +A8I CI Signal Indication25bis Commands List Request of Stored Number 25bis ResponsesList Request of Forbidden Number List Identification NumberRegisters Reg Unit Range Default DescriptionRegisters Registers +MR, +ER,+DR, and W commands Result Codes Data FAX+ER Lapm +DR ALT+DR None +ER NoneTerse Verbose Description Terse Verbose Description Example Setting Country/Regional CodesIndex Qcpc 46, 47, 48, 49 Index
Related manuals
Manual 57 pages 24.51 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.