Multi-Tech Systems MT5600BA-V92 manual Command Long Space Disconnect, Command Modem Reset

Page 8

 

 

 

Chapter 2 – AT Commands

Command:

Yn

Long Space Disconnect

 

 

Note: For use with MT5600BA and MT5600BR only.

Values:

 

n = 0 or 1

Default:

 

0

 

Description:

 

Y0

Disables sending/responding to a long space break signal on disconnect.

 

 

Y1

Enables long space disconnect. In non-error correction mode, the modem sends a

 

 

 

long space of four seconds prior to going on-hook. In non-error correction mode,

 

 

 

the modem responds to the receipt of a long space (i.e., a break signal greater than

 

 

 

1.6 seconds) by going on-hook.

Command:

Zn

Modem Reset

Values:

 

n = 0 or 1

Default:

 

None

 

Description:

 

The modem performs a soft reset and restores (recalls) the configuration profile according

 

 

to the parameter supplied. If no parameter is specified, zero is assumed.

 

 

Z0

Resets modem and restores Profile 0.

 

 

Z1

Resets modem and restores Profile 1.

 

 

Note: See also the &F and &W commands.

Command:

&Cn

Data Carrier Detect (DCD) Control

Values:

 

n = 0 or 1 (all models) 2, 3, 4, 5, 6, 7 (MT5600BA and MT5600BR only)

Default:

 

1, 3, 4

 

Description:

 

&C0

Turns off reset on loss of carrier.

 

 

&C1

A second way to turn off reset on loss of carrier.

 

 

&C2

DCD goes high 500ms after CONNECT message is generated.

 

 

&C3

DCD goes high when the CONNECT message is generated.

 

 

&C4

Disables &C5 and &C6 commands.

 

 

&C5

UNIX only: Holds DCD low until proper callback security password is entered or

 

 

 

until a disconnect occurs. This prevents UNIX login prompt from being displayed

 

 

 

before the callback security ENTER PASSWORD prompt appears.

 

 

&C6

Linux only: Waits to display the connect message until the proper callback security

 

 

 

password is entered.

 

 

&C7

Resets on loss of DCD.

Command:

&Dn Data Terminal Ready (DTR) Control

Values:

 

n = 0, 1, 2, or3

Default:

 

2

 

Description:

 

This command interprets the high to low transition of the DTR signal sent by the computer

 

 

according to the supplied parameter. The action taken depends on the current &Q setting.

 

 

&D0

&Q0, &Q5,&Q6: DTR is ignored (assumed high). Allows operation with computers

 

 

 

that do not provide DTR.

 

 

 

&Q1: DTR drop causes the modem to hang up. Autoanswer is not affected.

 

 

 

&Q2,&Q3: DTR drop causes the modem to hang up. Autoanswer is inhibited.

 

 

&D1

&Q0, &Q1, &Q5,&Q6: DTR drop is interpreted by the modem as if the

 

 

 

asynchronous escape sequence had been entered. The modem returns to

 

 

 

asynchronous command state without disconnecting.

 

 

 

&Q2,&Q3: DTR drop causes the modem to hang up. Autoanswer is inhibited.

 

 

&D2

&Q0–&Q6:DTR drop causes the modem to hang up. Autoanswer is inhibited.

 

 

&D3

&Q0, &Q1, &Q5,&Q6: DTR drop causes modem to perform a soft reset as if the Z

 

 

 

command were received. The &Y setting determines which profile is loaded.

 

 

 

&Q2,&Q3: DTR drop causes the modem to hang up. Autoanswer is inhibited.

 

 

 

&Q5 or &Q6 and +FCLASS=1 or +FCLASS=2: Same as for &Q0.

 

 

Note: If &D1, &D2,or &D3 is set, the modem will not dial without a DTR drop.

Command:

&En V.42 Error Correction Modes

 

 

Note: For use with MT5600BA and MT5600BR only.

Values:

 

n = 0, 1, or 2

Default:

 

1

 

Description:

 

&E0

V.42 non-error correction mode (V.42 disabled).

 

 

&E1

V.42 auto-reliable mode.

 

 

&E2

V.42 reliable mode (V.42 enabled).

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

8

Image 8
Contents MultiModem→ Warranty CopyrightRecord of Revisions TrademarksTable of Contents You must press Enter to send the command to the modem IntroductionAT Commands General CommandsCommand DS=n Dial Stored Telephone Number Command En Echo Command Mode CharactersCommand Hook Control Command Information RequestCommand Result Codes Enable/Disable Command ? Read Register ValueCommand Tone Dialing Command Result Code FormatCommand Long Space Disconnect Command Modem ResetCommand Data Carrier Detect DCD Control Command Dn Data Terminal Ready DTR ControlCommand Modem-Initiated Flow Control Command V.42bis Data CompressionCommand Load Factory Settings Command V.22bis Guard Tone ControlCommand Make/Break Dial Ratio Command Sync/Async ModeCommand Clear to Send CTS Control Command Data Set Ready DSR ControlCommand Store Current Configuration Command &Xn Synchronous Clock SourceCommand Select Profile for Hard Reset Command &Zn=x Store Telephone NumberCommand %En Line Quality Monitor Command Line Signal LevelCommand Line Signal Quality Command PCM Code SelectionCommand \Kn Break Control Command \Nn Error Correction Mode SelectionCommand \Vn Single Line Connect Message Report CommandsCountry/Region of Installation Command +MS= Modulation SelectionValues & Default SubparametersCommand MNP Extended Services Command Flash Memory DownloadCommand View Numbers in Blacklist Command View Delayed NumbersCommand *E Escape Remote Configuration Escape CommandsCommand +++ Escape Sequence Modem Connection Commands Command +PCW=n Call Waiting EnableCommand +PIG=n PCM Upstream Ignore Command +PQC=n Quick Connect ControlResult Code Force Full Startup Procedure Next ConnectionEnable Quick Connect Profile Save Caller ID Commands Callback Security CommandsData Compression Commands Command +DR Data Compression ReportingCommand +DS Data Compression Command +DS44 V.44 Compression SelectError Control Commands Command +EB Break Handling in Error Control OperationCommand +EFCS Bit Frame Check Sequence Command +ER Error Control Reporting+ESR? Command +ESR Selective RejectCommand +ETBM Call Termination Buffer Management DTE Commands Command +IFC DTE-Modem Local Flow ControlCommand +ILRR DTE-Modem Local Rate Reporting Reported RateModulation Command Command +IPR Fixed DTE RateCommand +MR Modulation Reporting Control +MCR Report SyntaxCall Control Command Command -STE= Set Telephony ExtensionBehavior in Data Mode +FCLASS=0 Behavior in Voice Mode +FCLASS=8Examples No Carrier ATS86? Test CommandCommand &T n Test Command Voice Commands Voice Commands OverviewConfiguration Commands Command +FCLASS=8 Select Voice ModeCommand +VNH= Automatic Hang-up Control Command +FLO Flow ControlVoice Commands Command +VIP Voice Initialize All ParametersCommand +VRX Start Modem Receive Record Command +VTS Send Voice TonesCommand +VTX Start Modem Transmit Playback Command +VGR Voice Gain Receive Record GainCommand +VGT Voice Gain Transmit Playback Volume +VTS Examples+VLS Example Command +VIT Voice Inactivity Timer DTE/ModemCommand +VLS Analog Source/Destination Selection Command +VRA Ringback Goes Away Timer Table of +VLS Command Options Label Primitives Description+VSP=1 IntervalCommand +VSM Compression Method Selection Command +VRN Ringback Never Appeared TimerCommand +VSD Silence Detection Quiet and Silence Command +VTD Beep Tone Duration Timer Command +VDR Distinctive RingCommand +VDT Control Tone Cadence Reporting Before using it DescriptionRate +VPR?Speakerphone Commands Command +VSP Speakerphone ON/OFFCommand +VGM Microphone Gain Command +VGS Speaker GainShielded Hex Event Report Description Code Voice Mode Shielded CodesUnformatted Form Reporting Caller ID Event Number 4 Extended Keypad Dtmf a V.8bis Commands Command +A8E V.8bis Operation ControlsCommand +A8I CI Signal Indication Default Values25bis Commands 25bis Responses List Request of Forbidden NumberList Identification Number List Request of Stored NumberRegisters Reg Unit Range Default DescriptionRegisters Registers +MR, +ER,+DR, and W commands Result Codes FAX Data+DR ALT +DR None+ER None +ER LapmTerse Verbose Description Terse Verbose Description Setting Country/Regional Codes ExampleIndex Qcpc 46, 47, 48, 49 Index
Related manuals
Manual 57 pages 24.51 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.