Multi-Tech Systems MT5600BA-V92 manual Call Control Command, Command -STE= Set Telephony Extension

Page 25

 

 

 

 

Chapter 2 – AT Commands

Call Control Command

 

 

Command: -STE=

Set Telephony Extension

 

 

Description:

This command enables/disables Line-In-Use, Extension Pickup, and Remote Hang up

 

detection features.

 

 

 

 

Note: Additional hardware may be required to support these features.

 

 

Syntax: -STE=<value>

 

 

 

Values:

<value> Decimal number corresponding to the selected bit-mapped options.

 

The bit fields are defined as follows:

 

 

 

Bit 0

Line-In-Use detection – enable/disable.

 

 

Bit 1

Extension Pickup – detection enable/disable.

 

 

Bit 2

Remote Hang up – detection enable/disable.

 

 

<value> (decimal)

Remote Hangup

Extension Pickup

Line-in-Use

 

0 (default)

Disabled

Disabled

Disabled

 

1

 

Disabled

Disabled

Enabled

 

2

 

Disabled

Enabled

Disabled

 

3

 

Disabled

Enabled

Enabled

 

4

 

Enabled

Disabled

Disabled

 

5

 

Enabled

Disabled

Enabled

 

6

 

Enabled

Enabled

Disabled

 

7

 

Enabled

Enabled

Enabled

Report Commands:

-STE? Reports current or selected values

 

 

 

-STE=? Reports supported range of parameter values

 

Result Codes:

OK <value> = 0-7

 

 

 

 

ERROR Otherwise.

 

 

 

Behavior in Data Mode (+FCLASS=0):

When on-hook, if the line is in use and an ATDT is issued, the modem will not go off-hook and will return with the message LINE-IN-USE.

When off-hook and either an extension is picked up or a line reversal is detected, the modem will drop the connection. The disconnect reason in register S86=25 (also defined for #UD). The user must flash the hook in order to get a dial tone because the remote server will be retraining.

If local handset is picked up while modem is off-hook, modem will do a link-disconnect, flash the hook for 1.5 seconds, then connect local handset to the line. Now, the user dial tone is on the local handset. Disconnect reason S86=25.

Behavior in Voice Mode (+FCLASS=8):

When in voice mode and an extension is picked-up, a <DLE>P is sent to the DTE. When the modem is off-hook, a line reversal may also be detected in which case a <DLE>l is sent to the DTE.

In voice mode, there is no blocking of ATDT when the line is in use. Also, there is no automatic hang-up in voice mode as in data mode. There is only the above stated <DLE> shielding event reporting.

Operation in Data Mode: Line-In-Use (Enabled by AT-STE=1,AT-STE=3,AT-STE=5, or AT-STE=7)

Case 1: Telephone Line is in Use

If an ATDT, ATDP or ATDL is issued while Line-In-Use detection is enabled and the telephone line is in use, the modem will immediately return the message LINE-IN-USE to the DTE without going off-hook, and then return to command mode.

Case 2: Telephone Line is in Use But Disconnected

If an ATDT, ATDP or ATDL is issued while Line-In-Use detection is enabled and the telephone line is NOT in use, the modem will go off-hook after a short pause, then respond with CONNECT or NO CARRIER message.

Case 3: Telephone Line is Not Connected to Modem

If an ATDT, ATDP or ATDL is issued while Line-In-Use detection is enabled and the telephone line is not connected, the modem will go off-hook momentarily, go back on- hook, then respond with NO DIAL TONE message.

Extension Pick-up (Enabled by AT-STE=2, AT-STE=3, AT-STE=6, or AT-STE=7):

Case 1: Modem off-hook, Local Handset Goes Off-Hook

If the local handset goes off-hook while the modem is in a data connection, the modem will then send a GSTN Clear down to the remote modem and then go on-hook. The modem will then send a NO CARRIER message to the DTE. A result code of 25 will be left in S86 register.

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

25

Image 25
Contents MultiModem→ Copyright WarrantyRecord of Revisions TrademarksTable of Contents Introduction You must press Enter to send the command to the modemGeneral Commands AT CommandsCommand En Echo Command Mode Characters Command DS=n Dial Stored Telephone NumberCommand Hook Control Command Information RequestCommand ? Read Register Value Command Result Codes Enable/DisableCommand Tone Dialing Command Result Code FormatCommand Modem Reset Command Long Space DisconnectCommand Data Carrier Detect DCD Control Command Dn Data Terminal Ready DTR ControlCommand V.42bis Data Compression Command Modem-Initiated Flow ControlCommand Load Factory Settings Command V.22bis Guard Tone ControlCommand Sync/Async Mode Command Make/Break Dial RatioCommand Clear to Send CTS Control Command Data Set Ready DSR ControlCommand &Xn Synchronous Clock Source Command Store Current ConfigurationCommand Select Profile for Hard Reset Command &Zn=x Store Telephone NumberCommand Line Signal Level Command %En Line Quality MonitorCommand Line Signal Quality Command PCM Code SelectionCommand \Nn Error Correction Mode Selection Command \Kn Break ControlCommand \Vn Single Line Connect Message Report CommandsCommand +MS= Modulation Selection Country/Region of InstallationValues & Default SubparametersCommand Flash Memory Download Command MNP Extended ServicesCommand View Numbers in Blacklist Command View Delayed NumbersCommand +++ Escape Sequence Escape CommandsCommand *E Escape Remote Configuration Command +PCW=n Call Waiting Enable Modem Connection CommandsCommand +PIG=n PCM Upstream Ignore Command +PQC=n Quick Connect ControlEnable Quick Connect Profile Save Force Full Startup Procedure Next ConnectionResult Code Callback Security Commands Caller ID CommandsCommand +DR Data Compression Reporting Data Compression CommandsCommand +DS Data Compression Command +DS44 V.44 Compression SelectCommand +EB Break Handling in Error Control Operation Error Control CommandsCommand +EFCS Bit Frame Check Sequence Command +ER Error Control ReportingCommand +ETBM Call Termination Buffer Management Command +ESR Selective Reject+ESR? Command +IFC DTE-Modem Local Flow Control DTE CommandsCommand +ILRR DTE-Modem Local Rate Reporting Reported RateCommand +IPR Fixed DTE Rate Modulation CommandCommand +MR Modulation Reporting Control +MCR Report SyntaxCommand -STE= Set Telephony Extension Call Control CommandBehavior in Data Mode +FCLASS=0 Behavior in Voice Mode +FCLASS=8Examples Command &T n Test Command Test CommandNo Carrier ATS86? Voice Commands Overview Voice CommandsConfiguration Commands Command +FCLASS=8 Select Voice ModeCommand +FLO Flow Control Command +VNH= Automatic Hang-up ControlCommand +VIP Voice Initialize All Parameters Voice CommandsCommand +VRX Start Modem Receive Record Command +VTS Send Voice TonesCommand +VGR Voice Gain Receive Record Gain Command +VTX Start Modem Transmit PlaybackCommand +VGT Voice Gain Transmit Playback Volume +VTS ExamplesCommand +VLS Analog Source/Destination Selection Command +VIT Voice Inactivity Timer DTE/Modem+VLS Example Table of +VLS Command Options Label Primitives Description Command +VRA Ringback Goes Away Timer+VSP=1 IntervalCommand +VSD Silence Detection Quiet and Silence Command +VRN Ringback Never Appeared TimerCommand +VSM Compression Method Selection Command +VDR Distinctive Ring Command +VTD Beep Tone Duration TimerCommand +VDT Control Tone Cadence Reporting Before using it Description+VPR? RateCommand +VSP Speakerphone ON/OFF Speakerphone CommandsCommand +VGM Microphone Gain Command +VGS Speaker GainUnformatted Form Reporting Caller ID Voice Mode Shielded CodesShielded Hex Event Report Description Code Event Number 4 Extended Keypad Dtmf a Command +A8E V.8bis Operation Controls V.8bis CommandsCommand +A8I CI Signal Indication Default Values25bis Commands List Request of Forbidden Number 25bis ResponsesList Identification Number List Request of Stored NumberRegisters Reg Unit Range Default DescriptionRegisters Registers +MR, +ER,+DR, and W commands Result Codes Data FAX+DR None +DR ALT+ER None +ER LapmTerse Verbose Description Terse Verbose Description Example Setting Country/Regional CodesIndex Qcpc 46, 47, 48, 49 Index
Related manuals
Manual 57 pages 24.51 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.