Multi-Tech Systems MT5600BA-V92 Modem Connection Commands, Command +PCW=n Call Waiting Enable

Page 17

 

 

Chapter 2 – AT Commands

Modem Connection Commands

Command: +PCW=n

Call Waiting Enable

Values:

n = 0, 1, or 2

Default:

2

 

Description:

Controls the action to be taken upon detection of a call waiting tone in V.92 mode.

 

Values specified by this command are not modified when an AT&F command is issued.

 

+PCW=0

Toggles V.24 Circuit 125 and collects Caller ID if enabled by +VCID.

 

+PCW=1

Hangs up.

 

+PCW=2

Ignores V.92 call waiting.

 

+PCW=? Displays the allowed values.

 

+PCW?

Displays the currrent values.

Command: +PIG=n

PCM Upstream Ignore

Values:

n = 0 or 1

 

Default:

1

 

Description:

Controls the use of PCM upstream during V.92 operation. PCM upstream allows faster

 

upload speeds to a V.92 server.

 

+PIG=0

Disables PCM upstream.

 

+PIG=1

Enables PCM upstream.

 

+PIG=?

Displays the allowed values.

 

+PIG?

Displays the current values.

Command: +PQC=n Quick Connect Control

Values:

n = 0, 1, 2, or 3

Default:

3

 

Description:

Controls the V.92 shortened Phase 1 and Phase 2 startup procedures (Quick Connect).

 

When line conditions are stable, quick connect results in shortened connect times;

 

however, significant fluctuations in line conditions from call to call can result in longer

 

connect times, in which case it may be advisable to disable quick connect.

 

+PQC=0

Enables Short Phase 1 and Short Phase 2 (Quick Connect).

 

+PQC=1

Enables Short Phase 1.

 

+PQC=2

Enables Short Phase 2.

 

+PQC=3

Disables Short Phase 1 and Short Phase 2.

 

+PQC=? Displays the allowed values.

 

+PQC?

Displays the current values.

Command: +PSS

Use Short Sequence

Description:

This command causes a calling modem to force either a V.92 short or full startup

 

sequence as defined by the +PQC command on the next and subsequent connections.

 

Syntax: +PSS=<value>

Values:

<value> Decimal number corresponding to the selected sequence.

 

 

0 The modems decide whether or not to use the short startup procedures.

 

 

The short startup procedures can only be used if enabled by the +PQC

 

 

command. Default

 

 

1 Reserved.

 

 

2 Forces the use of the full startup procedures on the next and subsequent

 

 

connections independent of the setting of the +PQC command.

Result Codes:

OK 0 - 2 in V.92 Mode (+MS=V.92)

 

ERROR Otherwise

Report Commands:

+PSS? Reports selected values.

 

+PSS=? Reports supported range of parameter values.

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

17

Image 17
Contents MultiModem→ Copyright WarrantyRecord of Revisions TrademarksTable of Contents Introduction You must press Enter to send the command to the modemGeneral Commands AT CommandsCommand En Echo Command Mode Characters Command DS=n Dial Stored Telephone NumberCommand Hook Control Command Information RequestCommand ? Read Register Value Command Result Codes Enable/DisableCommand Tone Dialing Command Result Code FormatCommand Modem Reset Command Long Space DisconnectCommand Data Carrier Detect DCD Control Command Dn Data Terminal Ready DTR ControlCommand V.42bis Data Compression Command Modem-Initiated Flow ControlCommand Load Factory Settings Command V.22bis Guard Tone ControlCommand Sync/Async Mode Command Make/Break Dial RatioCommand Clear to Send CTS Control Command Data Set Ready DSR ControlCommand &Xn Synchronous Clock Source Command Store Current ConfigurationCommand Select Profile for Hard Reset Command &Zn=x Store Telephone NumberCommand Line Signal Level Command %En Line Quality MonitorCommand Line Signal Quality Command PCM Code SelectionCommand \Nn Error Correction Mode Selection Command \Kn Break ControlCommand \Vn Single Line Connect Message Report CommandsCommand +MS= Modulation Selection Country/Region of InstallationValues & Default SubparametersCommand Flash Memory Download Command MNP Extended ServicesCommand View Numbers in Blacklist Command View Delayed NumbersCommand *E Escape Remote Configuration Escape CommandsCommand +++ Escape Sequence Command +PCW=n Call Waiting Enable Modem Connection CommandsCommand +PIG=n PCM Upstream Ignore Command +PQC=n Quick Connect ControlResult Code Force Full Startup Procedure Next ConnectionEnable Quick Connect Profile Save Callback Security Commands Caller ID CommandsCommand +DR Data Compression Reporting Data Compression CommandsCommand +DS Data Compression Command +DS44 V.44 Compression SelectCommand +EB Break Handling in Error Control Operation Error Control CommandsCommand +EFCS Bit Frame Check Sequence Command +ER Error Control Reporting+ESR? Command +ESR Selective RejectCommand +ETBM Call Termination Buffer Management Command +IFC DTE-Modem Local Flow Control DTE CommandsCommand +ILRR DTE-Modem Local Rate Reporting Reported RateCommand +IPR Fixed DTE Rate Modulation CommandCommand +MR Modulation Reporting Control +MCR Report SyntaxCommand -STE= Set Telephony Extension Call Control CommandBehavior in Data Mode +FCLASS=0 Behavior in Voice Mode +FCLASS=8Examples No Carrier ATS86? Test CommandCommand &T n Test Command Voice Commands Overview Voice CommandsConfiguration Commands Command +FCLASS=8 Select Voice ModeCommand +FLO Flow Control Command +VNH= Automatic Hang-up ControlCommand +VIP Voice Initialize All Parameters Voice CommandsCommand +VRX Start Modem Receive Record Command +VTS Send Voice TonesCommand +VGR Voice Gain Receive Record Gain Command +VTX Start Modem Transmit PlaybackCommand +VGT Voice Gain Transmit Playback Volume +VTS Examples+VLS Example Command +VIT Voice Inactivity Timer DTE/ModemCommand +VLS Analog Source/Destination Selection Table of +VLS Command Options Label Primitives Description Command +VRA Ringback Goes Away Timer+VSP=1 IntervalCommand +VSM Compression Method Selection Command +VRN Ringback Never Appeared TimerCommand +VSD Silence Detection Quiet and Silence Command +VDR Distinctive Ring Command +VTD Beep Tone Duration TimerCommand +VDT Control Tone Cadence Reporting Before using it Description+VPR? RateCommand +VSP Speakerphone ON/OFF Speakerphone CommandsCommand +VGM Microphone Gain Command +VGS Speaker GainShielded Hex Event Report Description Code Voice Mode Shielded CodesUnformatted Form Reporting Caller ID Event Number 4 Extended Keypad Dtmf a Command +A8E V.8bis Operation Controls V.8bis CommandsCommand +A8I CI Signal Indication Default Values25bis Commands List Request of Forbidden Number 25bis ResponsesList Identification Number List Request of Stored NumberRegisters Reg Unit Range Default DescriptionRegisters Registers +MR, +ER,+DR, and W commands Result Codes Data FAX+DR None +DR ALT+ER None +ER LapmTerse Verbose Description Terse Verbose Description Example Setting Country/Regional CodesIndex Qcpc 46, 47, 48, 49 Index
Related manuals
Manual 57 pages 24.51 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.