Multi-Tech Systems MT5600BA-V92 manual Command Modem-Initiated Flow Control

Page 9

Chapter 2 – AT Commands

Command:

&En Modem-Initiated Flow Control

 

Note: For use with MT5600BA and MT5600BR only.

Values:

n = 3, 4, or 5

Default:

4

 

Description:

&E3

Flow control disabled.

 

&E4

CTS/RTS hardware flow control.

 

&E5

XON/XOFF software flow control.

 

Note: See also the L5 and &K commands.

Command:

&En V.42bis Data Compression

 

Note: For use with MT5600BA and MT5600BR only.

Values:

n = 14 or 15

Default:

15

 

Description:

&E14

V.42bis data compression disabled.

 

&E15

V.42bis data compression enabled.

 

Note: This command controls only V.42bis data compression, whereas the %C command

 

 

controls both V.42bis and MNP-5 data compression. The command in effect is the

 

 

one last entered. See also the L5 command.

Command:

&Fn Load Factory Settings

Values:

n = 0 or 1

Default:

None

 

Description:

&F0

Loads factory configuration 0.

 

&F1

Loads factory configuration 1.

 

Note: See also the Z, L5, and &V commands.

Command:

&Gn V.22bis Guard Tone Control

Values:

n = 0, 1, or2

Default:

Varies by country

Description:

&G0

Disables guard tone.

 

&G1

Sets guard tone to 550 Hz.

 

&G2

Sets guard tone to 1800 Hz.

 

Note: The &G command is not used in North America, and may not be permitted in some

 

 

countries.

Command:

&Kn Flow Control Selection

Values:

n = 0, 3, 4, 5, or6

Defaults:

3 (data modem mode)

 

6 (fax modem and voice modes)

Description:

&K0

Disables flow control.

 

&K3

Enables CTS/RTS hardware flow control.

 

&K4

Enables XON/XOFF software flow control.

 

&K5

Enables transparent XON/XOFF flow control.

 

&K6

Enables both CTS/RTS and XON/XOFF flow control.

 

Note:

See also the &E command

Command:

&Mn Communications Mode

 

Values:

n = 0–3

 

Default:

0

 

 

Description:

This command determines the DTR operating mode. The modem treats the &M command

 

as a subset of the &Q command.

 

 

&M0

Selects direct asynchronous operation. Command sequence &M0\N0 selects

 

 

 

normal buffered mode, but command sequence \N0&M0 selects direct mode. This

 

 

 

is because the \N0 command is analogous to the &Q6 command.

 

 

&M1

Selects synchronous connect mode with asynchronous offline command mode.

 

 

&M2 Note: For use with the MT5656ZDX and MT5656ZDX-V only. Selects synchronous

 

 

connect mode with asynchronous offline command mode.

 

 

 

Same as &M1 except that &M2 enables DTR dialing of directory slot 0. The modem

 

 

disconnects if DTR is low for more than the period stored in S25.

 

 

&M3

Selects synchronous connect mode. This mode allows DTR to act as a talk/data

 

 

 

switch. A call is manually initiated while DTR is inactive; when it becomes active,

 

 

 

the handshake proceeds in originate or answer mode according to S14 bit 7.

 

 

 

Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)

9

Image 9
Contents MultiModem→ Copyright WarrantyRecord of Revisions TrademarksTable of Contents Introduction You must press Enter to send the command to the modemGeneral Commands AT CommandsCommand En Echo Command Mode Characters Command DS=n Dial Stored Telephone NumberCommand Hook Control Command Information RequestCommand ? Read Register Value Command Result Codes Enable/DisableCommand Tone Dialing Command Result Code FormatCommand Modem Reset Command Long Space DisconnectCommand Data Carrier Detect DCD Control Command Dn Data Terminal Ready DTR ControlCommand V.42bis Data Compression Command Modem-Initiated Flow ControlCommand Load Factory Settings Command V.22bis Guard Tone ControlCommand Sync/Async Mode Command Make/Break Dial RatioCommand Clear to Send CTS Control Command Data Set Ready DSR ControlCommand &Xn Synchronous Clock Source Command Store Current ConfigurationCommand Select Profile for Hard Reset Command &Zn=x Store Telephone NumberCommand Line Signal Level Command %En Line Quality MonitorCommand Line Signal Quality Command PCM Code SelectionCommand \Nn Error Correction Mode Selection Command \Kn Break ControlCommand \Vn Single Line Connect Message Report CommandsCommand +MS= Modulation Selection Country/Region of InstallationValues & Default SubparametersCommand Flash Memory Download Command MNP Extended ServicesCommand View Numbers in Blacklist Command View Delayed NumbersEscape Commands Command +++ Escape SequenceCommand *E Escape Remote Configuration Command +PCW=n Call Waiting Enable Modem Connection CommandsCommand +PIG=n PCM Upstream Ignore Command +PQC=n Quick Connect ControlForce Full Startup Procedure Next Connection Enable Quick Connect Profile SaveResult Code Callback Security Commands Caller ID CommandsCommand +DR Data Compression Reporting Data Compression CommandsCommand +DS Data Compression Command +DS44 V.44 Compression SelectCommand +EB Break Handling in Error Control Operation Error Control CommandsCommand +EFCS Bit Frame Check Sequence Command +ER Error Control ReportingCommand +ESR Selective Reject Command +ETBM Call Termination Buffer Management+ESR? Command +IFC DTE-Modem Local Flow Control DTE CommandsCommand +ILRR DTE-Modem Local Rate Reporting Reported RateCommand +IPR Fixed DTE Rate Modulation CommandCommand +MR Modulation Reporting Control +MCR Report SyntaxCommand -STE= Set Telephony Extension Call Control CommandBehavior in Data Mode +FCLASS=0 Behavior in Voice Mode +FCLASS=8Examples Test Command Command &T n Test CommandNo Carrier ATS86? Voice Commands Overview Voice CommandsConfiguration Commands Command +FCLASS=8 Select Voice ModeCommand +FLO Flow Control Command +VNH= Automatic Hang-up ControlCommand +VIP Voice Initialize All Parameters Voice CommandsCommand +VRX Start Modem Receive Record Command +VTS Send Voice TonesCommand +VGR Voice Gain Receive Record Gain Command +VTX Start Modem Transmit PlaybackCommand +VGT Voice Gain Transmit Playback Volume +VTS ExamplesCommand +VIT Voice Inactivity Timer DTE/Modem Command +VLS Analog Source/Destination Selection+VLS Example Table of +VLS Command Options Label Primitives Description Command +VRA Ringback Goes Away Timer+VSP=1 IntervalCommand +VRN Ringback Never Appeared Timer Command +VSD Silence Detection Quiet and SilenceCommand +VSM Compression Method Selection Command +VDR Distinctive Ring Command +VTD Beep Tone Duration TimerCommand +VDT Control Tone Cadence Reporting Before using it Description+VPR? RateCommand +VSP Speakerphone ON/OFF Speakerphone CommandsCommand +VGM Microphone Gain Command +VGS Speaker GainVoice Mode Shielded Codes Unformatted Form Reporting Caller IDShielded Hex Event Report Description Code Event Number 4 Extended Keypad Dtmf a Command +A8E V.8bis Operation Controls V.8bis CommandsCommand +A8I CI Signal Indication Default Values25bis Commands List Request of Forbidden Number 25bis ResponsesList Identification Number List Request of Stored NumberReg Unit Range Default Description RegistersRegisters Registers +MR, +ER,+DR, and W commands Result Codes Data FAX+DR None +DR ALT+ER None +ER LapmTerse Verbose Description Terse Verbose Description Example Setting Country/Regional CodesIndex Qcpc 46, 47, 48, 49 Index
Related manuals
Manual 57 pages 24.51 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.