LSI SAS6160 manual Alias Phy Device Capabilities SAS Address Type, Sdmcli show phy Calhoun

Page 69

LSISAS6160 SAS Switch User Guide

Chapter 4: SAS Domain Manager Command Line Interface Sample Output for Show Com-

 

mand

x1xxxxxxx - Attached STP Initiator xx1xxxxxx - Attached SSP Initiator xxx1xxxxx - Attached SATA Host xxxx1xxxx - Attached SMP Target xxxxx1xxx - Attached STP Target xxxxxx1xx - Attached SSP Target xxxxxxx1x - Attached SATA Target xxxxxxxx1 - Attached SATA Port Selector

PhyAttached

===================================== ==========================================

Alias /

Phy

RA

VP LS/S

ZG

Alias /

Phy

Device

Capabilities

SAS Address

SAS Address

Type

IIIITTTTS

Tchoupitoulas-------------------------------------

00

T

-

6.0

-

------------------------------------------

Poydras

000

Switch

000010000

Tchoupitoulas

01

T

-

6.0

-

Poydras

001

Switch

000010000

Tchoupitoulas

02

T

-

6.0

-

Poydras

002

Switch

000010000

Tchoupitoulas

03

T

-

6.0

-

Poydras

003

Switch

000010000

Tchoupitoulas

04

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

05

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

06

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

07

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

08

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

09

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

10

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

11

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

12

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

13

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

14

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

15

T

-

-

 

*

----------------

---

None

000000000

Tchoupitoulas

16

T

-

-

 

*

----------------

---

None

000000000

 

Not all output

shown in this example.

 

 

 

Rampart

32

T

-

-

 

*

----------------

---

None

000000000

Rampart

33

T

-

-

 

*

----------------

---

None

000000000

Rampart

34

T

-

-

 

*

----------------

---

None

000000000

Rampart

35

T

-

-

 

*

----------------

---

None

000000000

Rampart

36

D

*

6.0

-

500605b0000210bd 000

End

101000100

Rampart

37

D

*

-

 

-

---------------- ---

None

000001000

4.3.7

show phy <alias>

 

 

 

SDMCLI> show phy Calhoun

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: In the following example, T = Table, S = Subtractive, and D = Direct.

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

-RA - Routing Attributes

-VP - Virtual PHY

-Zone Grp

LSI Corporation September 2010

Page 69

Image 69
Contents LSISAS6160 SAS Switch Revision History Table of Contents SAS Domain Manager Command Line Interface Chapter FeaturesLSISAS6160 Switch Serial Attached Scsi and the SAS6160 SwitchLSISAS6160 Resource Management Block Diagram of the LSISAS6160 Switch Link between Two Single SAS Phys SAS Phys, Ports, and ConnectorsNarrow and Wide SAS Ports Mini SAS 4x Cable SAS Connectors and CablingOnly the storage within its zone or zones Minimize conflictsAcross the entire Zpsds SAS Zoning OverviewGroups and zone sets manually by using the SDM utility Following figure shows a simple example of zoningCreating SAS Zones Overview SAS Routing and Zoning Configuration for Zoning Example Creating Zone Groups Connecting Devices to the SAS6160 SwitchExample 1, Multiple Servers and JBODs Example 3, Multiple Servers and a Cascading Switch Example 4, High Availability Example 5, Large Data Storage Topology Example 6, Cascaded Switches Example 7, Switches in a Star Tree Configuration Identifying Switch Components Unpacking the SwitchTo interpret the LEDs on the switch Carton contains the following itemsSAS6160 Connectors Installing the SAS6160 SwitchCables SAS6160 LEDsRack. These options are shown in the following figure Mounting Shelf in a Rack Setting a Static IP Address Connecting to a Host Changing the Default Static IP AddressExit SDM-CLI and power cycle the switch Exit SDM-GUI and power cycle the switchUsing SDM-GUI For example1 FCC Connecting SAS and Sata Hardware Safety NoticesCanada Mark Vcci Bsmi 5 CCC Installation and Hardware Setup Safety Notices Starting SDM-GUI SDM-GUI AccountsEmbedded SDM only supports a single domain OptionsFile, Server, and Help Menu Options Views Tab Information is available to both admin and user accountsFor zoning View End Device TableAlias Table View Zone Groups View Zone GroupsView Zone Sets View Zone SetsThis section, click the hyperlinks on the Domain tab Domain TabNode100, and so on Alias ManagementView/Delete Aliases command Domain. You also can also this command to delete aliasesView/Delete Aliases Zone set and the two associated zone groups Connector WizardBox and clicking the Delete button Group to communicate with each otherMaximum number of 248, the wizard displays an error message Guide you through the configuration processCheck box and clicking the Delete button Zone group to communicate with each otherCreate Zone Group Manually Configure Zone Groups Create Zone GroupView Zone Group Time of activation. shows the View Zone Group windowModify Zone Group Delete Zone GroupBinary 0, as defined by the SAS 2.0 specification Maximum password length is 32 charactersPassword MatrixZone set View Zone Set windowView Zone Set Modify Zone SetActivate/Deactivate Zone Set Activate/Deactivate Zone SetDelete Zone Set Window and then clicking DeleteDevice Tree and Properties Tab Devices TabSelected device. In , the domain properties are shown Following figure shows the Properties tabProperties Tab Environmentals Tab Background loopThose connections Following figure shows the Attached Devices tabAttached Devices Tab Following figure shows the Phys tab Selected expanderZone Group Tab Zone Group TabSuccessful update This tab contains the following commandsUpdate Firmware Operations TabEnable/Disable/Reset Following figure shows the Enable/Disable/Reset windowReset Switch PhysAs shown in the following figures Configure IPCommand arguments Command Usage SyntaxHelp command SDM-CLI Commands„ help command Domain focus domain name„ passwd admin Passwd admin user„ passwd user Exit„ alias delete „ show phy „ show alias„ show zonegroup „ show zoneset„ zonegroup create name „ zonegroup add name sas addressaliasphy„ zonegroup delete single name „ zonegroup delete all noconfirm„ zoneset activate name Set membership„ zoneset add name zone group zone group „ zoneset create name„ zoneset passwd Sample Output for Show CommandSdmcli show alias Sdmcli show alias CalhounSdmcli show device Calhoun Sdmcli show phy Sdmcli show domainShow domain Show phySdmcli show phy Calhoun Alias Phy Device Capabilities SAS Address TypeRA Routing Attributes VP Virtual PHY Zone Grp Show phy aliasZoning Inactive * phy may be assigned to a zone group Zoning Active Zone Group NumberSdmcli show version Sdmcli show phy Lincoln01SDM-CLI Version SDM-D Version Show phy alias phySdmcli show zoneset active Sdmcli show zonegroup ZoneOne#001Show zoneset data name Sdmcli show zoneset data ZoneOne Show zonegroup nameXip -i 500062b15555557f get exp Xip -i get availTroubleshooting