Liebert RAC2-8 manual List of Alarms

Page 32

Section 4: Glossary of Control Functions

The following terms are used to describe the control and operation of the Liebert RAC2-8. For each term, both the operator actions and the system performance are defined. Refer to this section if necessary while setting up your system or to answer any questions about how the system operates.

Alarms

For each alarm condition or warning condition, the RAC2-8 locally annunciates the condition, locally displays the message, provides a time and date stamp, stores up to 20 messages in memory, and displays the message at a remote terminal. Alarms are produced for normal alarm conditions such as Common Alarm inputs and Temp/Hum alarms. Warnings are produced for conditions such as Manual Override.

List of Alarms

 

 

UNIT XX COMMON ALARM

Alarm

EMERGENCY POWER OFF

Alarm

EMERGENCY POWER OP.

Alarm

MANUAL OVERRIDE

Alarm

 

HIGH TEMP ALARM

Alarm

 

LOW TEMP ALARM

Alarm

 

HIGH HUM ALARM

Alarm

 

LOW HUM ALARM

Alarm

 

STBY NOT AVAILABLE

 

Alarm

STBY UNIT FAILED

Alarm

 

UNIT XX FORCED ON Warning

(no audible alarm)

UNIT XX FORCED OFF Warning

(no audible alarm)

UNIT XX RESTORED Warning

(no audible alarm)

Liebert RAC2-8 27

Image 32
Contents $XWRð&KDQJHRYHUý&RQWUROOHU Table of Contents Table of Figures RAC2-8 UnitPage Introduction Page Operation InstallationTo start up the RAC2-8 Page Operation Glossary of Control Functions for more detailsSequencing Status Screens cont’d Status Sub-menuDelay UnitsSet Options Sub-menu cont’d Status Sub-menu cont’dSet Options Sub-menu Function Delays TEMP/HUM Password StandbyAlarm Sub-menu Set Clock Sub-menu DateTime DAY of WeekUnit 01 Forced on Force OFF Restore Return Terminal LOG onStatus Screen Setup Zones/Units Options Setup Zones/Units Options cont’dNumber of ZONES/NUMBER of Units PER Zone Unit StatusUnit Shutdown on Alarm Emergency Power Units08 0 no Set Clock Alarms Review and Alarms ClearUnit Labels Override a Unit Set Modem Options Set Modem Options cont’d Setup Temp/Humid OptionsSetup Temp/Humid Options cont’d Setup Standby Unit Options Display SS Alarm Block Set New PasswordAlarms List of AlarmsAlarm Annunciation Alarm CommunicationsAlarm Delay AutochangeoverAutosequencing Clear Alarms Common Alarm-InputsCommon Alarm-Output KeyDelay Emergency Power OFF EPOEmergency Power Operation Hold DelayHumidity Alarms Humidity LockoutInactive Unit IntervalNormal Temperature PasswordPower Failure Mode OverrideRestart Delay RestoreStandby Testing Running UnitsTemperature Alarms Temperature SensitivityTemperature Staging TerminalZones Installation TB2 RAC2-8 Dimensional Enclosure Diagram RAC2-8 Component Arrangement RAC2-8 Connection Diagram RAC2-8 Switch and Jumper Settings