GarrettCom manual Ordering Information, Magnum 3000 Stackable Hubs and Concentrators

Page 11

Magnum 3000 Stackable Hubs

Installation and User Guide (07/06)

1.3Ordering Information

Magnum 3000 Stackable Hubs and Concentrators

Magnum 3024

Base Chassis with 24 RJ-45 ports, shielded connectors

Magnum 3012

Base Chassis with 12 RJ-45 ports, shielded connectors

ETSI and NEBS-certified models, -48VDC powered

Magnum 3012-NEBS

NEBS Level 3 tested and certified with -48VDC power supply

 

Base Chassis with 12 RJ-45 ports

Magnum 3024-NEBS

NEBS Level 3 tested and certified with -48VDC power supply

 

Base Chassis with 24 RJ-45 ports

Note: for Dual-Source DC and other special options, RFQ to sales@garrettcom.com

Network Management Options:

Magnum 3000-MB

SNMP option, Embedded Agent Board

Magnum 3000-AGT

SNMP option, Embedded Agent Box as a separate stack unit

Magnum 3000-NMS

"SNMPc" PC / Windows-based Network Management

 

Software product from Castle Rock Computing.

Port Modules (PMs)**:

Magnum RPM-BNC

Module with 1 BNC connector, internal termination switch

Magnum RPM-TP

Module w/ 1 shielded female RJ-45 connector + up-link switch

Magnum RPM-AUI

Module with 1 AUI (DB-15 female) connector, with slide lock

Magnum RPM-DTE

Module with 1 DTE (DB-15 male) connector, with lock posts

Magnum RPM-FST

Module w/ mm* Fiber ST “twist” 10BASE-FL dual connector

Magnum RPM-SMF

Module w/ single-modeFiber connector

Magnum BPM-BNC

Local Bridge Module with 1 BNC connector

Magnum BPM-AUI

Local Bridge Module with 1 AUI connector

Magnum BPM-FST

Local Bridge Module with mm* Fiber ST connector

Magnum BPM-TP

Local Bridge Module with 1 RJ-45 connector + uplink switch

Magnum PM-FP

Face Plate - cover for unused front slots

*mm = multi-mode.

**These items must be included to convey configuration information to the factory. For example, to order a Model 3024 Hub with a BNC-type RPM option factory installed in the rear bonus port slot, you must include Model "3024-PM" and Model RPM-BNC as separate line items on the same order, in order to specify that the RPM-BNC is to be factory-configured in the rear bonus port.

GARRETTCOM, INC.reserves the right to change specifications, performance characteristics and/or model offerings without notice.

www . GarrettCom . com

4

Image 11
Contents Magnum Stackable Hubs Trademarks Magnum Stackable Hubs Installation and User GuideContacting GarrettCom, Inc GarrettCom, IncRevisions PrefaceTable of Contents Specifications Magnum 3024, MagnumIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum Packaging DC Power Supply OptionsLED Indicators on Chassis Front WarrantySpecifications Bridge Port Modules BPMs Bonus Ports Specifications Repeater Port Modules RPMs Bonus PortsNetwork Management Options Etsi and NEBS-certified models, -48VDC poweredOrdering Information Magnum 3000 Stackable Hubs and ConcentratorsInspecting the Package and Product Introduction Magnum 3012 and 3024 Stackable HubsProduct Description Magnum 3000 Stackable Hubs Stacking Magnum 3000s Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slotWww . GarrettCom . com Cable Stack3 4 5 6 7 4a, Magnum 3012 Hub, Front View Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slotRear Bonus Slot, Port Modules PMs 5c Magnum 3012 internal layout with configured Bonus Port Included only when PM is factory installedCBL-AUI PM Ribbon cable with 16 pin connectorBonus port for optional PM card BPM shown Features and Benefits, Magnum 3024 and 3012 Hubs Wing B Wing a ApplicationsConnecting Twisted Pair RJ-45, Unshielded or Shielded Installation and OperationConnecting Ethernet Media Connecting Drop Cable 10BASE5 DTE Connecting ThickNet 10BASE5 AUIConnecting ThinNet 10BASE2 BNC Associated ports at each end of the fiber optic segment Connecting Fiber Optic SC-type, Snap-OnConnecting Single-Mode Fiber Optic SMF At regular intervals you must use the color-coded strand on’cvr Rack-mountingOptional BPM-BNC BPM-AUI BPM-TP BPM-FST Introduction Magnum Port ModulesProduct Description, Port Modules RPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TPDirectly Magnum RPM-BNC RPM-BNCRPM-AUI Www . GarrettCom . com Magnum RPM-DTE RPM-DTE2 AUI Pin Assignments Pin Function3 km RPM-FST Fiber ST, Twist-lock ConnectorMagnum RPM-FST Jumper AcrossMagnum RPM-SMF RPM-FSC Fiber SC, Snap-in ConnectorRPM-SMF Single-mode Fiber Magnum RPM-FSC10 Km RPM-TP Twisted PairJumper Across Distances Supported Not usedMagnum BPM-BNC BPM-BNCMagnum BPM-FST BPM-AUIBPM-FST Segment distances up to 100m Ft., or shielded twisted pair wiringBPM-TP Environments with maximumEmbedded Snmp Agent, Model 3000-MB Introduction Simple Network Management Protocol Snmp AgentsSnmp Agents Description Standard Repeater MIB and Extensions Separate Agent Box, Model 3000-AGTWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installing the Embedded Agent Board, MB Installation, General Information3b Magnum 3024, Top View with Cover Off Remove Chassis Cover of the hubSet Group # Stack Address Magnum 3024/3012 Magnum Snmp Agent BoardSwitch # 7 and Switch # 8 are not used Address\switchAgent Configuration, Embedded Agent and Agent Box Versions Eight-Position DIP Switch Configuration TablePerforming Self Diagnostics Automatic Agent IP Address ConfigurationManual IP Address Configuration Community # Names Manager Bootp IP/NAMEBootp Bootp IP/NAME Address IP/ NameManager Manager # IP/NAME Port Community Community Community # Name S Manager11/12/93 1145 Cr Other Convenience CommandsBefore Calling for Assistance No Problem Found When Calling for AssistanceReturn Material Authorization RMA Procedure Shipping and Packaging Information Appendix a Warranty InformationB3.0 Applications for DC Powered Hubs Appendix B Internal DC Power Supply OptionB1.0 Specifications for Magnum 3000S Power Supply Internal -48VDC OptionThis section describes InstallationB4.0 B5.0 Operation Appendix C Internal DC Dual-Source Power OptionTroubleshooting C1.0 Specifications for Magnum 3000S HubsC3.0 DUAL-SOURCE OPTION, Theory of Operation C4.0 Features and Benefits of the DUAL-SOURCE DesignC5.1 UL Requirements C5.0 InstallationC7.0 Operation C6.0 Ordering InformationExample Magnum 3012-48VDC Example Magnum 3024-24VDC or Magnum 3012-125VDC