1.0Specifications - Magnum 3024, Magnum 3012

Performance

 

Data Rate:

10 Mbps

RPM Partitioning:

Enforced after 32 consecutive collisions

RPM Reconnect:

Occurs after 512 bits error-free reception

BPM Auto-Learning Address List:

256 nodes capacity

BPM Filtering and Forwarding Rate:

14,880 pps max.

Maximum Ethernet Segment Lengths

 

 

DTE (AUI Drop Cable)

- 50 m (164 ft)

10BASE-T (twisted pair)

-

100 m (328 ft)

Shielded twisted pair

-

150m (492 ft)

10BASE2 ThinNet (BNC)

- 185 m (607 ft)

10BASE5 ThickNet

- 500 m (1,640 ft)

FOIRL multi-mode Fiber optic

-

1 km (3,281 ft)

10BASE-FL multi-mode Fiber optic

- 2 km (6,562 ft)

Single-mode Fiber optic

-

10 km (32,810 ft)

Network Standards

Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2, 10BASE-FL & FOIRL, and DTE

Operating Environment

 

Ambient Temperature:

25ºF to 120ºF (-5ºC to 50ºC)

Storage Temperature:

-40ºF to 185ºF (-40ºC to 85ºC)

Ambient Relative Humidity: 5% to 95% (non-condensing)

Altitude: -200 to 13,000 Ft. (-60 to 4000 m)

Conformal coating option: Request quote

Port Connector Types

RJ-45:

Shielded, 8-Pin Female (Note: Shielded 10BASE-T

connectors accept either unshielded or shielded wiring

plugs for standard twisted pair media wiring.)

Fiber Optic:

ST (Twist-Lock Connector, for single and multi-mode)

Fiber Optic:

SC (Snap-in Connector, for multi-mode fiber cables only)

ThinNet:

BNC

AUI:

D-Sub 15-Pin Female (with slide lock)

DTE:

D-Sub 15-Pin Male (with lock posts)

Power Supply (Internal)

AC Power Connector: IEC-type, male recessed, rear of chassis

Input Voltage: 100 - 240 vac (auto-ranging)

Input Frequency: 47 - 63 Hz (auto-ranging)

Power Consumption: Model 3024: 18 watts typical; 30 watts max, Model 3012: 10 watts typical; 20 watts max, 3000-AGT: 9 watts typical; 20 watts max,

www . GarrettCom . com

1

Image 8 Contents
Magnum Stackable Hubs Magnum Stackable Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPreface RevisionsSpecifications Magnum 3024, Magnum Table of ContentsIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum DC Power Supply Options LED Indicators on Chassis FrontWarranty PackagingSpecifications Repeater Port Modules RPMs Bonus Ports Specifications Bridge Port Modules BPMs Bonus PortsEtsi and NEBS-certified models, -48VDC powered Ordering InformationMagnum 3000 Stackable Hubs and Concentrators Network Management OptionsIntroduction Magnum 3012 and 3024 Stackable Hubs Inspecting the Package and ProductProduct Description Magnum 3000 Stackable Hubs Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slot Stacking Magnum 3000sWww . GarrettCom . com Stack Cable3 4 5 6 7 Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slot 4a, Magnum 3012 Hub, Front ViewRear Bonus Slot, Port Modules PMs Included only when PM is factory installed 5c Magnum 3012 internal layout with configured Bonus PortCBL-AUI PM Ribbon cable with 16 pin connectorBonus port for optional PM card BPM shown Features and Benefits, Magnum 3024 and 3012 Hubs Applications Wing B Wing aConnecting Twisted Pair RJ-45, Unshielded or Shielded Installation and OperationConnecting Ethernet Media Connecting Drop Cable 10BASE5 DTE Connecting ThickNet 10BASE5 AUIConnecting ThinNet 10BASE2 BNC Connecting Fiber Optic SC-type, Snap-On Connecting Single-Mode Fiber Optic SMFAt regular intervals you must use the color-coded strand on Associated ports at each end of the fiber optic segmentRack-mounting ’cvrOptional Introduction Magnum Port Modules Product Description, Port ModulesRPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TP BPM-BNC BPM-AUI BPM-TP BPM-FSTDirectly Magnum RPM-BNC RPM-BNCRPM-AUI Www . GarrettCom . com RPM-DTE 2 AUI Pin AssignmentsPin Function Magnum RPM-DTERPM-FST Fiber ST, Twist-lock Connector Magnum RPM-FSTJumper Across 3 kmRPM-FSC Fiber SC, Snap-in Connector RPM-SMF Single-mode FiberMagnum RPM-FSC Magnum RPM-SMFRPM-TP Twisted Pair Jumper Across Distances SupportedNot used 10 KmBPM-BNC Magnum BPM-BNCMagnum BPM-FST BPM-AUIBPM-FST Ft., or shielded twisted pair wiring BPM-TPEnvironments with maximum Segment distances up to 100mEmbedded Snmp Agent, Model 3000-MB Introduction Simple Network Management Protocol Snmp AgentsSnmp Agents Description Separate Agent Box, Model 3000-AGT Standard Repeater MIB and ExtensionsWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installation, General Information Installing the Embedded Agent Board, MBRemove Chassis Cover of the hub 3b Magnum 3024, Top View with Cover OffMagnum Snmp Agent Board Set Group # Stack Address Magnum 3024/3012Address\switch Agent Configuration, Embedded Agent and Agent Box VersionsEight-Position DIP Switch Configuration Table Switch # 7 and Switch # 8 are not usedPerforming Self Diagnostics Automatic Agent IP Address ConfigurationManual IP Address Configuration Bootp IP/NAME Bootp Bootp IP/NAMEAddress IP/ Name Community # Names ManagerCommunity Community # Name S Manager Manager Manager # IP/NAME Port CommunityOther Convenience Commands 11/12/93 1145 CrBefore Calling for Assistance No Problem Found When Calling for AssistanceReturn Material Authorization RMA Procedure Appendix a Warranty Information Shipping and Packaging InformationAppendix B Internal DC Power Supply Option B1.0 Specifications for Magnum 3000SPower Supply Internal -48VDC Option B3.0 Applications for DC Powered HubsThis section describes InstallationB4.0 Appendix C Internal DC Dual-Source Power Option TroubleshootingC1.0 Specifications for Magnum 3000S Hubs B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C3.0 DUAL-SOURCE OPTION, Theory of OperationC5.0 Installation C5.1 UL RequirementsC6.0 Ordering Information Example Magnum 3012-48VDCExample Magnum 3024-24VDC or Magnum 3012-125VDC C7.0 Operation