GarrettCom Magnum 3000 manual Features and Benefits, Magnum 3024 and 3012 Hubs

Page 22

Magnum 3000 Stackable Hubs

Installation and User Guide (07/06)

2.6Features and Benefits, Magnum 3024 and 3012 Hubs

„24 Port and 12 Port "Building Block" Hub Models

The 24 port units provide high density and low cost-per-port. The 12 port units provide minimum add-on and entry-level system cost. The two units may be combined and mixed in one stack.

„Optional SNMP Management

Magnum 3000 Stackable Hubs may optionally be configured with an SNMP agent. The SNMP agent is available as an embedded daughter board mounted inside of a 3024 or 3012, or as a separate unit which is the same physical size as a 3024 or 3012 unit and which supports a 3000 Stack. One SNMP agent serves all the Magnum 3000 units in one stack.

„Stackable and Scaleable Configurations

Up to twenty Magnum 3000 units may be stacked, thus supporting up to 500 Ethernet segments operating as a single repeater. Both Hubs and an SNMP Agent Box may easily be added to the stack for expansion of the system. This provides for low initial cost and for graceful growth of network systems.

„Bonus Ports for any Ethernet Media Type

An optional rear-mounted bonus port may be configured with an RPM of any media type, providing flexible connectivity to backbones or other devices and nodes.

„Optional Bridge Port Modules

The Magnum 3000 Stackable Hubs can be optionally configured with a BPM as the bonus port. BPMs contain a miniature, self-learning local bridge module capable of filtering and forwarding packets at full Ethernet wire speed. A BPM may be used to bridge-isolate a local segment (such as all of the nodes connected to a stack) having significant local inter-node traffic, thus boosting overall network performance.

„Rack-mount or Table-top, Front-access Connectors and Status LEDs Match the installation requirements of any environment with stacking flexibility. Magnum 3000 Hubs may be mounted in a standard RETMA rack or stacked on a shelf or table-top. The 10BASE-T ports and the associated LEDs are adjacent to each other on the front of the units for convenient status monitoring.

„Small, compact units, 1 U

At only 1.75 inches (4.45 cm) high, Magnum 3024 and 3012 Hubs save rack space and provide high port density in the wiring closet.

„Proven reliability

Thousands of Magnum 3012 and 3024 Stackable Hubs have been installed in critical applications world-wide for multiple years, and have demonstrated exceptionally low failure rates. Calculated MTBF is up to 140,000 hours, depending on specific configuration and methodology.

www . GarrettCom . com

15

Image 22
Contents Magnum Stackable Hubs Magnum Stackable Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPreface RevisionsSpecifications Magnum 3024, Magnum Table of ContentsIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum Warranty DC Power Supply OptionsLED Indicators on Chassis Front PackagingSpecifications Repeater Port Modules RPMs Bonus Ports Specifications Bridge Port Modules BPMs Bonus PortsMagnum 3000 Stackable Hubs and Concentrators Etsi and NEBS-certified models, -48VDC poweredOrdering Information Network Management OptionsIntroduction Magnum 3012 and 3024 Stackable Hubs Inspecting the Package and ProductProduct Description Magnum 3000 Stackable Hubs Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slot Stacking Magnum 3000sWww . GarrettCom . com Stack Cable3 4 5 6 7 Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slot 4a, Magnum 3012 Hub, Front ViewRear Bonus Slot, Port Modules PMs Included only when PM is factory installed 5c Magnum 3012 internal layout with configured Bonus PortBonus port for optional PM card BPM shown PM Ribbon cable with 16 pin connectorCBL-AUI Features and Benefits, Magnum 3024 and 3012 Hubs Applications Wing B Wing aConnecting Ethernet Media Installation and OperationConnecting Twisted Pair RJ-45, Unshielded or Shielded Connecting ThinNet 10BASE2 BNC Connecting ThickNet 10BASE5 AUIConnecting Drop Cable 10BASE5 DTE At regular intervals you must use the color-coded strand on Connecting Fiber Optic SC-type, Snap-OnConnecting Single-Mode Fiber Optic SMF Associated ports at each end of the fiber optic segmentRack-mounting ’cvrOptional RPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TP Introduction Magnum Port ModulesProduct Description, Port Modules BPM-BNC BPM-AUI BPM-TP BPM-FSTRPM-AUI RPM-BNCDirectly Magnum RPM-BNC Www . GarrettCom . com Pin Function RPM-DTE2 AUI Pin Assignments Magnum RPM-DTEJumper Across RPM-FST Fiber ST, Twist-lock ConnectorMagnum RPM-FST 3 kmMagnum RPM-FSC RPM-FSC Fiber SC, Snap-in ConnectorRPM-SMF Single-mode Fiber Magnum RPM-SMFNot used RPM-TP Twisted PairJumper Across Distances Supported 10 KmBPM-BNC Magnum BPM-BNCBPM-FST BPM-AUIMagnum BPM-FST Environments with maximum Ft., or shielded twisted pair wiringBPM-TP Segment distances up to 100mSnmp Agents Description Introduction Simple Network Management Protocol Snmp AgentsEmbedded Snmp Agent, Model 3000-MB Separate Agent Box, Model 3000-AGT Standard Repeater MIB and ExtensionsWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installation, General Information Installing the Embedded Agent Board, MBRemove Chassis Cover of the hub 3b Magnum 3024, Top View with Cover OffMagnum Snmp Agent Board Set Group # Stack Address Magnum 3024/3012Eight-Position DIP Switch Configuration Table Address\switchAgent Configuration, Embedded Agent and Agent Box Versions Switch # 7 and Switch # 8 are not usedManual IP Address Configuration Automatic Agent IP Address ConfigurationPerforming Self Diagnostics Address IP/ Name Bootp IP/NAMEBootp Bootp IP/NAME Community # Names ManagerCommunity Community # Name S Manager Manager Manager # IP/NAME Port CommunityOther Convenience Commands 11/12/93 1145 CrBefore Calling for Assistance Return Material Authorization RMA Procedure When Calling for AssistanceNo Problem Found Appendix a Warranty Information Shipping and Packaging InformationPower Supply Internal -48VDC Option Appendix B Internal DC Power Supply OptionB1.0 Specifications for Magnum 3000S B3.0 Applications for DC Powered HubsB4.0 InstallationThis section describes C1.0 Specifications for Magnum 3000S Hubs Appendix C Internal DC Dual-Source Power OptionTroubleshooting B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C3.0 DUAL-SOURCE OPTION, Theory of OperationC5.0 Installation C5.1 UL RequirementsExample Magnum 3024-24VDC or Magnum 3012-125VDC C6.0 Ordering InformationExample Magnum 3012-48VDC C7.0 Operation