GarrettCom Magnum 3000 Remove Chassis Cover of the hub, 3b Magnum 3024, Top View with Cover Off

Page 44

Magnum 3000 Stackable Hubs

Installation and User Guide (07/06)

Step 1. Remove Chassis Cover of the hub

The chassis cover is made in one piece, forming the top and the front of the unit. There are 7 screws located on top and 3 on the front of the unit as shown below. Remove these screws. Once these are removed, the chassis cover/front is easily lifted forward and off of the chassis base. (See Figure 5.3a).

10 Phillips Head Screws

One piece cover,

top and front

Chassis Cover

Magnum 3000

Stackable Hub

1

2

3

4

5

6

7

8

9

1310

14 11

15

1216

17

18

19

20

21

22

23

24

GARRETT

Ventilation

Slots

Magnum 3024

Figure 5.3a: Removing Magnum 3024 / 3012 Chassis Cover

Step 2. Insert the Agent Board (Magnum 3024 and 3012 Hubs)

Looking down into the Magnum 3024 or 3012 hub as shown in the illustration Figure 4.3c below, the Embedded Agent Board mounts on top of the other printed circuit boards in the left-rear area of the unit. Three screws with stand-offs hold it firmly in place in the correct position.

Back of Unit

 

 

 

Power Supply

AC Power

Optional Bonus Port

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left Side

Front of Unit

Right Side

Figure 5.3b: Magnum 3024, Top View with Cover Off

The Magnum SNMP embedded agent daughter board, Figure 4.3d, connects into the DB-9 connector "P1" on the back of the Magnum 3000 unit with a cable, and

www . GarrettCom . com

37

Image 44
Contents Magnum Stackable Hubs Magnum Stackable Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPreface RevisionsSpecifications Magnum 3024, Magnum Table of ContentsIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum DC Power Supply Options LED Indicators on Chassis FrontWarranty PackagingSpecifications Repeater Port Modules RPMs Bonus Ports Specifications Bridge Port Modules BPMs Bonus PortsEtsi and NEBS-certified models, -48VDC powered Ordering InformationMagnum 3000 Stackable Hubs and Concentrators Network Management OptionsIntroduction Magnum 3012 and 3024 Stackable Hubs Inspecting the Package and ProductProduct Description Magnum 3000 Stackable Hubs Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slot Stacking Magnum 3000sWww . GarrettCom . com Stack Cable3 4 5 6 7 Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slot 4a, Magnum 3012 Hub, Front ViewRear Bonus Slot, Port Modules PMs Included only when PM is factory installed 5c Magnum 3012 internal layout with configured Bonus PortCBL-AUI PM Ribbon cable with 16 pin connectorBonus port for optional PM card BPM shown Features and Benefits, Magnum 3024 and 3012 Hubs Applications Wing B Wing aConnecting Twisted Pair RJ-45, Unshielded or Shielded Installation and OperationConnecting Ethernet Media Connecting Drop Cable 10BASE5 DTE Connecting ThickNet 10BASE5 AUIConnecting ThinNet 10BASE2 BNC Connecting Fiber Optic SC-type, Snap-On Connecting Single-Mode Fiber Optic SMFAt regular intervals you must use the color-coded strand on Associated ports at each end of the fiber optic segmentRack-mounting ’cvrOptional Introduction Magnum Port Modules Product Description, Port ModulesRPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TP BPM-BNC BPM-AUI BPM-TP BPM-FSTDirectly Magnum RPM-BNC RPM-BNCRPM-AUI Www . GarrettCom . com RPM-DTE 2 AUI Pin AssignmentsPin Function Magnum RPM-DTERPM-FST Fiber ST, Twist-lock Connector Magnum RPM-FSTJumper Across 3 kmRPM-FSC Fiber SC, Snap-in Connector RPM-SMF Single-mode FiberMagnum RPM-FSC Magnum RPM-SMFRPM-TP Twisted Pair Jumper Across Distances SupportedNot used 10 KmBPM-BNC Magnum BPM-BNCMagnum BPM-FST BPM-AUIBPM-FST Ft., or shielded twisted pair wiring BPM-TPEnvironments with maximum Segment distances up to 100mEmbedded Snmp Agent, Model 3000-MB Introduction Simple Network Management Protocol Snmp AgentsSnmp Agents Description Separate Agent Box, Model 3000-AGT Standard Repeater MIB and ExtensionsWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installation, General Information Installing the Embedded Agent Board, MBRemove Chassis Cover of the hub 3b Magnum 3024, Top View with Cover OffMagnum Snmp Agent Board Set Group # Stack Address Magnum 3024/3012Address\switch Agent Configuration, Embedded Agent and Agent Box VersionsEight-Position DIP Switch Configuration Table Switch # 7 and Switch # 8 are not usedPerforming Self Diagnostics Automatic Agent IP Address ConfigurationManual IP Address Configuration Bootp IP/NAME Bootp Bootp IP/NAMEAddress IP/ Name Community # Names ManagerCommunity Community # Name S Manager Manager Manager # IP/NAME Port CommunityOther Convenience Commands 11/12/93 1145 CrBefore Calling for Assistance No Problem Found When Calling for AssistanceReturn Material Authorization RMA Procedure Appendix a Warranty Information Shipping and Packaging InformationAppendix B Internal DC Power Supply Option B1.0 Specifications for Magnum 3000SPower Supply Internal -48VDC Option B3.0 Applications for DC Powered HubsThis section describes InstallationB4.0 Appendix C Internal DC Dual-Source Power Option TroubleshootingC1.0 Specifications for Magnum 3000S Hubs B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C3.0 DUAL-SOURCE OPTION, Theory of OperationC5.0 Installation C5.1 UL RequirementsC6.0 Ordering Information Example Magnum 3012-48VDCExample Magnum 3024-24VDC or Magnum 3012-125VDC C7.0 Operation