GarrettCom Magnum 3000 Separate Agent Box, Model 3000-AGT, Standard Repeater MIB and Extensions

Page 40

Magnum 3000 Stackable HubsInstallation and User Guide (07/06)

extensions data are in this firmware. The firmware in the EPROMs performs the data collection and execution functions, and operates as the local controller and interface to the network manager.

5.1.2Separate Agent Box, Model 3000-AGT

The Magnum 3000 SNMP Agent Box operates the same as the embedded

board agent. It is packaged as a separate unit, enclosed in a box that is the same dimensions as a 3024 or 3012 so that it fits neatly into a Magnum 3000 stack. It is a complete modular unit with its own internal auto-ranging power supply.

Magnum 3000 SNMP Agent

GARRETT

PWR

Figure 5.1a: Magnum 3000 Agent Box, Model 3000-AGT, Front View

The Magnum 3000-AGT agent box is connected into a stack by the Inter- Repeater Bus (IRB). There are two IRB connectors at the right-rear, permitting the agent box unit to be installed at the bottom or top of a stack using one IRB connector, or to be inserted into the middle of a stack using two IRB connectors. The IRB cable connectors are made with "notches / keys" to insure a proper connection.

P1: Also used to setup IP addresses and

P1: Remote Terminal

configuration files for complex networks.

RS-232 Port

 

P3

P4

Figure 5.1b: Magnum 3000 Agent Box, Model 3000-AGT, Rear View

The agent logically resides on the IRB and will not be visible to network management software packages as a separate port or user. For network integrity, the agent is designed so that it cannot be disconnected by network managers accidentally or purposefully. Similarly, the agent operates in the stack attached to the IRB and does not need to use a port in any attached Magnum 3000 unit to be connected.

5.1.3Standard Repeater MIB and Extensions

www . GarrettCom . com

33

Image 40
Contents Magnum Stackable Hubs Magnum Stackable Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPreface RevisionsSpecifications Magnum 3024, Magnum Table of ContentsIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum DC Power Supply Options LED Indicators on Chassis FrontWarranty PackagingSpecifications Repeater Port Modules RPMs Bonus Ports Specifications Bridge Port Modules BPMs Bonus PortsEtsi and NEBS-certified models, -48VDC powered Ordering InformationMagnum 3000 Stackable Hubs and Concentrators Network Management OptionsIntroduction Magnum 3012 and 3024 Stackable Hubs Inspecting the Package and ProductProduct Description Magnum 3000 Stackable Hubs Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slot Stacking Magnum 3000sWww . GarrettCom . com Stack Cable3 4 5 6 7 Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slot 4a, Magnum 3012 Hub, Front ViewRear Bonus Slot, Port Modules PMs Included only when PM is factory installed 5c Magnum 3012 internal layout with configured Bonus PortBonus port for optional PM card BPM shown PM Ribbon cable with 16 pin connectorCBL-AUI Features and Benefits, Magnum 3024 and 3012 Hubs Applications Wing B Wing aConnecting Ethernet Media Installation and OperationConnecting Twisted Pair RJ-45, Unshielded or Shielded Connecting ThinNet 10BASE2 BNC Connecting ThickNet 10BASE5 AUIConnecting Drop Cable 10BASE5 DTE Connecting Fiber Optic SC-type, Snap-On Connecting Single-Mode Fiber Optic SMFAt regular intervals you must use the color-coded strand on Associated ports at each end of the fiber optic segmentRack-mounting ’cvrOptional Introduction Magnum Port Modules Product Description, Port ModulesRPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TP BPM-BNC BPM-AUI BPM-TP BPM-FSTRPM-AUI RPM-BNCDirectly Magnum RPM-BNC Www . GarrettCom . com RPM-DTE 2 AUI Pin AssignmentsPin Function Magnum RPM-DTERPM-FST Fiber ST, Twist-lock Connector Magnum RPM-FSTJumper Across 3 kmRPM-FSC Fiber SC, Snap-in Connector RPM-SMF Single-mode FiberMagnum RPM-FSC Magnum RPM-SMFRPM-TP Twisted Pair Jumper Across Distances SupportedNot used 10 KmBPM-BNC Magnum BPM-BNCBPM-FST BPM-AUIMagnum BPM-FST Ft., or shielded twisted pair wiring BPM-TPEnvironments with maximum Segment distances up to 100mSnmp Agents Description Introduction Simple Network Management Protocol Snmp AgentsEmbedded Snmp Agent, Model 3000-MB Separate Agent Box, Model 3000-AGT Standard Repeater MIB and ExtensionsWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installation, General Information Installing the Embedded Agent Board, MBRemove Chassis Cover of the hub 3b Magnum 3024, Top View with Cover OffMagnum Snmp Agent Board Set Group # Stack Address Magnum 3024/3012Address\switch Agent Configuration, Embedded Agent and Agent Box VersionsEight-Position DIP Switch Configuration Table Switch # 7 and Switch # 8 are not usedManual IP Address Configuration Automatic Agent IP Address ConfigurationPerforming Self Diagnostics Bootp IP/NAME Bootp Bootp IP/NAMEAddress IP/ Name Community # Names ManagerCommunity Community # Name S Manager Manager Manager # IP/NAME Port CommunityOther Convenience Commands 11/12/93 1145 CrBefore Calling for Assistance Return Material Authorization RMA Procedure When Calling for AssistanceNo Problem Found Appendix a Warranty Information Shipping and Packaging InformationAppendix B Internal DC Power Supply Option B1.0 Specifications for Magnum 3000SPower Supply Internal -48VDC Option B3.0 Applications for DC Powered HubsB4.0 InstallationThis section describes Appendix C Internal DC Dual-Source Power Option TroubleshootingC1.0 Specifications for Magnum 3000S Hubs B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C3.0 DUAL-SOURCE OPTION, Theory of OperationC5.0 Installation C5.1 UL RequirementsC6.0 Ordering Information Example Magnum 3012-48VDCExample Magnum 3024-24VDC or Magnum 3012-125VDC C7.0 Operation