GarrettCom Magnum 3000 Address IP/ Name, Bootp IP/NAME, Community # Names Manager, Subnetmask IP

Page 48

Magnum 3000 Stackable Hubs

Installation and User Guide (07/06)

From the top menu prompt > , type: C {Cr}.

On the terminal, the prompt will appear: CFG>

The agent configuration menu consists of the following commands:

ADDRESS

BOOTP

COMMUNITY

DISPLAY

GATEWAY

MANAGER

NAMESERVER

SUBNETMASK

EXIT

To see a command selection menu, type: help {Cr}. On the terminal screen, a menu with command lines and the meaning of each command will appear:

A[DDRESS] [ IP/ NAME]

 

IP address

B[OOTP] [IP/NAME]

 

Bootp Server

C[OMMUNITY] [# [NAME[S] [MANAGER....]]]

 

Communities access:

S - Allow Set operations

 

Managers - list of IP addresses and/or names

D[ISPLAY]

Display whole configuration

E[XIT]

 

Exit configuration

G[ATEWAY] [# [IP [SUBNETIP [MASKIP]]]]

 

Gateways

M[ANAGER] [# [IP/NAME [PORT] COMMUNITY]]

Managers

N[AMESERVER] [# [IP/NAME]]

 

Name Servers

S[UBNETMASK] [IP]

 

Subnet mask

(end of “terminal screen” illustration)

 

 

Command or Function Listing

1.ADDRESS: A[DDRESS] [ IP/ NAME]

The "Address" command is used to define and/or display an agent's IP address.

To set an IP address, type: A [ address value ] {Cr} ( Example: >A 45.9.0.38 {Cr} )

To display the current IP address, type: A{Cr}

2. BOOTP

B[OOTP] [IP/NAME]

Used to define or display the IP address and/or name of your BOOTP server.

To set, type: B [address value/name] {Cr}

( Example: >B 45.9.0.171 )

www . GarrettCom . com

41

Image 48
Contents Magnum Stackable Hubs Magnum Stackable Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPreface RevisionsSpecifications Magnum 3024, Magnum Table of ContentsIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum DC Power Supply Options LED Indicators on Chassis FrontWarranty PackagingSpecifications Repeater Port Modules RPMs Bonus Ports Specifications Bridge Port Modules BPMs Bonus PortsEtsi and NEBS-certified models, -48VDC powered Ordering InformationMagnum 3000 Stackable Hubs and Concentrators Network Management OptionsIntroduction Magnum 3012 and 3024 Stackable Hubs Inspecting the Package and ProductProduct Description Magnum 3000 Stackable Hubs Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slot Stacking Magnum 3000sWww . GarrettCom . com Stack Cable3 4 5 6 7 Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slot 4a, Magnum 3012 Hub, Front ViewRear Bonus Slot, Port Modules PMs Included only when PM is factory installed 5c Magnum 3012 internal layout with configured Bonus PortPM Ribbon cable with 16 pin connector Bonus port for optional PM card BPM shownCBL-AUI Features and Benefits, Magnum 3024 and 3012 Hubs Applications Wing B Wing aInstallation and Operation Connecting Ethernet MediaConnecting Twisted Pair RJ-45, Unshielded or Shielded Connecting ThickNet 10BASE5 AUI Connecting ThinNet 10BASE2 BNCConnecting Drop Cable 10BASE5 DTE Connecting Fiber Optic SC-type, Snap-On Connecting Single-Mode Fiber Optic SMFAt regular intervals you must use the color-coded strand on Associated ports at each end of the fiber optic segmentRack-mounting ’cvrOptional Introduction Magnum Port Modules Product Description, Port ModulesRPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TP BPM-BNC BPM-AUI BPM-TP BPM-FSTRPM-BNC RPM-AUIDirectly Magnum RPM-BNC Www . GarrettCom . com RPM-DTE 2 AUI Pin AssignmentsPin Function Magnum RPM-DTERPM-FST Fiber ST, Twist-lock Connector Magnum RPM-FSTJumper Across 3 kmRPM-FSC Fiber SC, Snap-in Connector RPM-SMF Single-mode FiberMagnum RPM-FSC Magnum RPM-SMFRPM-TP Twisted Pair Jumper Across Distances SupportedNot used 10 KmBPM-BNC Magnum BPM-BNCBPM-AUI BPM-FSTMagnum BPM-FST Ft., or shielded twisted pair wiring BPM-TPEnvironments with maximum Segment distances up to 100mIntroduction Simple Network Management Protocol Snmp Agents Snmp Agents DescriptionEmbedded Snmp Agent, Model 3000-MB Separate Agent Box, Model 3000-AGT Standard Repeater MIB and ExtensionsWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installation, General Information Installing the Embedded Agent Board, MBRemove Chassis Cover of the hub 3b Magnum 3024, Top View with Cover OffMagnum Snmp Agent Board Set Group # Stack Address Magnum 3024/3012Address\switch Agent Configuration, Embedded Agent and Agent Box VersionsEight-Position DIP Switch Configuration Table Switch # 7 and Switch # 8 are not usedAutomatic Agent IP Address Configuration Manual IP Address ConfigurationPerforming Self Diagnostics Bootp IP/NAME Bootp Bootp IP/NAMEAddress IP/ Name Community # Names ManagerCommunity Community # Name S Manager Manager Manager # IP/NAME Port CommunityOther Convenience Commands 11/12/93 1145 CrBefore Calling for Assistance When Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Appendix a Warranty Information Shipping and Packaging InformationAppendix B Internal DC Power Supply Option B1.0 Specifications for Magnum 3000SPower Supply Internal -48VDC Option B3.0 Applications for DC Powered HubsInstallation B4.0This section describes Appendix C Internal DC Dual-Source Power Option TroubleshootingC1.0 Specifications for Magnum 3000S Hubs B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C3.0 DUAL-SOURCE OPTION, Theory of OperationC5.0 Installation C5.1 UL RequirementsC6.0 Ordering Information Example Magnum 3012-48VDCExample Magnum 3024-24VDC or Magnum 3012-125VDC C7.0 Operation