The family of standard connector types for BPMs is shown in Figure 2.5b.

Figure 2.5b: Magnum BPM Modules for Bonus Ports (left to right above) BPM-BNC, BPM-AUI, BPM-FST, BPM-TP

(Note: When an RPM-AUI type is configured as a bonus port, it is typically implemented at the factory as an AUI connector with a ribbon cable to header pins on the main board. The functionality is the same as the RPM-AUI card.)

For application flexibility, any of the Magnum PMs may be specified for factory configuration at the time of order. It is also possible for the Bonus Port slot to be configured in the field by a trained technician.

NOTE: When adding a Port Module to the Bonus Port slot in the field, it is necessary to have a Port Module connector cable (part number PM-CBL available as a spare part from GCI) in addition to the desired PM. See Figure 2.5a and 2.5b.

Figures 2.5a and 2.5b show the internal layout of the Magnum 3012 and 3024, respectively. When installing a PM into the Bonus Port slot of the Magnum 3012, the 16-pin header labeled J1/B (also labeled RPM) should be used. The red stripe of the PM connector cable should connect to pin 1of header J1/B.

Bonus port for optional

PM card (BPM shown)

J1

(AUI)

J1/B

(RPM)

NOTE:

 

Use J1 (AUI) and for Basic AUI ports

(Included only when PM is factory installed

Use J1/B (RPM) for PMs

 

May be ordered separately as part #CBL-PM

Figure 2.5c: Magnum 3012 internal layout with configured Bonus Port

www . GarrettCom . com

13

Image 20
Contents Magnum Stackable Hubs Magnum Stackable Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPreface RevisionsSpecifications Magnum 3024, Magnum Table of ContentsIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum DC Power Supply Options LED Indicators on Chassis FrontWarranty PackagingSpecifications Repeater Port Modules RPMs Bonus Ports Specifications Bridge Port Modules BPMs Bonus PortsEtsi and NEBS-certified models, -48VDC powered Ordering InformationMagnum 3000 Stackable Hubs and Concentrators Network Management OptionsIntroduction Magnum 3012 and 3024 Stackable Hubs Inspecting the Package and ProductProduct Description Magnum 3000 Stackable Hubs Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slot Stacking Magnum 3000sWww . GarrettCom . com Stack Cable3 4 5 6 7 Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slot 4a, Magnum 3012 Hub, Front ViewRear Bonus Slot, Port Modules PMs Included only when PM is factory installed 5c Magnum 3012 internal layout with configured Bonus PortCBL-AUI PM Ribbon cable with 16 pin connectorBonus port for optional PM card BPM shown Features and Benefits, Magnum 3024 and 3012 Hubs Applications Wing B Wing aConnecting Twisted Pair RJ-45, Unshielded or Shielded Installation and OperationConnecting Ethernet Media Connecting Drop Cable 10BASE5 DTE Connecting ThickNet 10BASE5 AUIConnecting ThinNet 10BASE2 BNC Connecting Fiber Optic SC-type, Snap-On Connecting Single-Mode Fiber Optic SMFAt regular intervals you must use the color-coded strand on Associated ports at each end of the fiber optic segmentRack-mounting ’cvrOptional Introduction Magnum Port Modules Product Description, Port ModulesRPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TP BPM-BNC BPM-AUI BPM-TP BPM-FSTDirectly Magnum RPM-BNC RPM-BNCRPM-AUI Www . GarrettCom . com RPM-DTE 2 AUI Pin AssignmentsPin Function Magnum RPM-DTERPM-FST Fiber ST, Twist-lock Connector Magnum RPM-FSTJumper Across 3 kmRPM-FSC Fiber SC, Snap-in Connector RPM-SMF Single-mode FiberMagnum RPM-FSC Magnum RPM-SMFRPM-TP Twisted Pair Jumper Across Distances SupportedNot used 10 KmBPM-BNC Magnum BPM-BNCMagnum BPM-FST BPM-AUIBPM-FST Ft., or shielded twisted pair wiring BPM-TPEnvironments with maximum Segment distances up to 100mEmbedded Snmp Agent, Model 3000-MB Introduction Simple Network Management Protocol Snmp AgentsSnmp Agents Description Separate Agent Box, Model 3000-AGT Standard Repeater MIB and ExtensionsWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installation, General Information Installing the Embedded Agent Board, MBRemove Chassis Cover of the hub 3b Magnum 3024, Top View with Cover OffMagnum Snmp Agent Board Set Group # Stack Address Magnum 3024/3012Address\switch Agent Configuration, Embedded Agent and Agent Box VersionsEight-Position DIP Switch Configuration Table Switch # 7 and Switch # 8 are not usedPerforming Self Diagnostics Automatic Agent IP Address ConfigurationManual IP Address Configuration Bootp IP/NAME Bootp Bootp IP/NAMEAddress IP/ Name Community # Names ManagerCommunity Community # Name S Manager Manager Manager # IP/NAME Port CommunityOther Convenience Commands 11/12/93 1145 CrBefore Calling for Assistance No Problem Found When Calling for AssistanceReturn Material Authorization RMA Procedure Appendix a Warranty Information Shipping and Packaging InformationAppendix B Internal DC Power Supply Option B1.0 Specifications for Magnum 3000SPower Supply Internal -48VDC Option B3.0 Applications for DC Powered HubsThis section describes InstallationB4.0 Appendix C Internal DC Dual-Source Power Option TroubleshootingC1.0 Specifications for Magnum 3000S Hubs B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C3.0 DUAL-SOURCE OPTION, Theory of OperationC5.0 Installation C5.1 UL RequirementsC6.0 Ordering Information Example Magnum 3012-48VDCExample Magnum 3024-24VDC or Magnum 3012-125VDC C7.0 Operation