GarrettCom Magnum 3000 manual Other Convenience Commands, 11/12/93 1145 Cr

Page 50

Magnum 3000 Stackable HubsInstallation and User Guide (07/06)

After new subnet configuration information is set in operation, it will reside in NVRAM. Powering down the Magnum 3000 will not destroy it, and at power up the agent will read the configuration information from NVRAM and start operations with it.

5.4.3Other Convenience Commands

From the top menu, one can also set the time and date. The time and date do NOT reside in NVRAM and will be lost at power down. From the prompt, type:

T [ mm/dd/yy] [hh:mm] {Cr}

Example:

>T 11/12/93 11:45 {Cr}

sets the date and (military) time.

To display the version and Ethernet physical address, from the prompt, type: V {Cr} On the terminal, a message with version number and information about the processor, system controller, Ethernet controller, and physical Ethernet address will appear in response.

Example: >V{Cr}

Garrett Communication Embedded Agent Version 01.01

Processor 3003 Controller 13

Ethernet Controller 30003003 Ethernet address 00 00 1A 18 0E 05

>

www . GarrettCom . com

43

Image 50 Contents
Magnum Stackable Hubs Magnum Stackable Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPreface RevisionsSpecifications Magnum 3024, Magnum Table of ContentsIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum Warranty DC Power Supply OptionsLED Indicators on Chassis Front PackagingSpecifications Repeater Port Modules RPMs Bonus Ports Specifications Bridge Port Modules BPMs Bonus PortsMagnum 3000 Stackable Hubs and Concentrators Etsi and NEBS-certified models, -48VDC poweredOrdering Information Network Management OptionsIntroduction Magnum 3012 and 3024 Stackable Hubs Inspecting the Package and ProductProduct Description Magnum 3000 Stackable Hubs Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slot Stacking Magnum 3000sWww . GarrettCom . com Stack Cable3 4 5 6 7 Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slot 4a, Magnum 3012 Hub, Front ViewRear Bonus Slot, Port Modules PMs Included only when PM is factory installed 5c Magnum 3012 internal layout with configured Bonus PortCBL-AUI PM Ribbon cable with 16 pin connectorBonus port for optional PM card BPM shown Features and Benefits, Magnum 3024 and 3012 Hubs Applications Wing B Wing aConnecting Twisted Pair RJ-45, Unshielded or Shielded Installation and OperationConnecting Ethernet Media Connecting Drop Cable 10BASE5 DTE Connecting ThickNet 10BASE5 AUIConnecting ThinNet 10BASE2 BNC At regular intervals you must use the color-coded strand on Connecting Fiber Optic SC-type, Snap-OnConnecting Single-Mode Fiber Optic SMF Associated ports at each end of the fiber optic segmentRack-mounting ’cvrOptional RPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TP Introduction Magnum Port ModulesProduct Description, Port Modules BPM-BNC BPM-AUI BPM-TP BPM-FSTDirectly Magnum RPM-BNC RPM-BNCRPM-AUI Www . GarrettCom . com Pin Function RPM-DTE2 AUI Pin Assignments Magnum RPM-DTEJumper Across RPM-FST Fiber ST, Twist-lock ConnectorMagnum RPM-FST 3 kmMagnum RPM-FSC RPM-FSC Fiber SC, Snap-in ConnectorRPM-SMF Single-mode Fiber Magnum RPM-SMFNot used RPM-TP Twisted PairJumper Across Distances Supported 10 KmBPM-BNC Magnum BPM-BNCMagnum BPM-FST BPM-AUIBPM-FST Environments with maximum Ft., or shielded twisted pair wiringBPM-TP Segment distances up to 100mEmbedded Snmp Agent, Model 3000-MB Introduction Simple Network Management Protocol Snmp AgentsSnmp Agents Description Separate Agent Box, Model 3000-AGT Standard Repeater MIB and ExtensionsWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installation, General Information Installing the Embedded Agent Board, MBRemove Chassis Cover of the hub 3b Magnum 3024, Top View with Cover OffMagnum Snmp Agent Board Set Group # Stack Address Magnum 3024/3012Eight-Position DIP Switch Configuration Table Address\switchAgent Configuration, Embedded Agent and Agent Box Versions Switch # 7 and Switch # 8 are not usedPerforming Self Diagnostics Automatic Agent IP Address ConfigurationManual IP Address Configuration Address IP/ Name Bootp IP/NAMEBootp Bootp IP/NAME Community # Names ManagerCommunity Community # Name S Manager Manager Manager # IP/NAME Port CommunityOther Convenience Commands 11/12/93 1145 CrBefore Calling for Assistance No Problem Found When Calling for AssistanceReturn Material Authorization RMA Procedure Appendix a Warranty Information Shipping and Packaging InformationPower Supply Internal -48VDC Option Appendix B Internal DC Power Supply OptionB1.0 Specifications for Magnum 3000S B3.0 Applications for DC Powered HubsThis section describes InstallationB4.0 C1.0 Specifications for Magnum 3000S Hubs Appendix C Internal DC Dual-Source Power OptionTroubleshooting B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C3.0 DUAL-SOURCE OPTION, Theory of OperationC5.0 Installation C5.1 UL RequirementsExample Magnum 3024-24VDC or Magnum 3012-125VDC C6.0 Ordering InformationExample Magnum 3012-48VDC C7.0 Operation
Related manuals
Manual 59 pages 6.23 Kb