GarrettCom Magnum 3000 manual Rpm-Bnc, Rpm-Aui, Directly Magnum RPM-BNC

Page 30

Magnum 3000 Stackable Hubs

Installation and User Guide (07/06)

4.2.1RPM-BNC

The Magnum RPM-BNC repeater module is equipped with a standard

10BASE2 coax connector. This RPM performs full IEEE 802.3 repeater functionality and is used for 10BASE2 ThinNet (commonly referred to as BNC) connections.

The RPM-BNC module is designed with a special switch-selectable internal termination function that eliminates the need for a "tee" connector and a 50 ohm terminator. To take advantage of internal termination, the slide switch should be in the "DOWN" (or right-side) position. In this configuration, the 10BASE2 segment is

directly

Magnum RPM-BNC

attached to the BNC port where it is internally terminated. When the switch is in the "UP" (or left-side) position, the BNC port requires a "tee" connector (not supplied) and a 50 ohm terminator for proper termination. Certain applications may require a "tee" connector, used as a tap, to allow the 10BASE2 coax segment to continue on past the RPM-BNC connection.

The RPM-BNC module includes one partition (PART) and one receive (RX) LED, which are visible beside the connector. The PART LED illuminates AMBER to indicate that the segment

has been automatically

Standard BNC

Internal Termination

Slide Switch

partitioned. As soon as

10BASE2 Connector

 

 

 

 

 

normal reception resumes,

 

1

Partition LED

 

 

the segment will be

 

2

Receive LED

automatically re-

 

1

 

 

established. The RX LED

 

2

 

 

 

 

illuminates GREEN

 

 

 

intermittently to indicate data is being received.

Important Note: for the RPM-BNC Termination Switch -

DOWN (or right) = Internally Terminated, UP (or left) = "T" Connector required.

4.2.2RPM-AUI

www . GarrettCom . com

23

Image 30
Contents Magnum Stackable Hubs Magnum Stackable Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPreface RevisionsSpecifications Magnum 3024, Magnum Table of ContentsIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum Warranty DC Power Supply OptionsLED Indicators on Chassis Front PackagingSpecifications Repeater Port Modules RPMs Bonus Ports Specifications Bridge Port Modules BPMs Bonus PortsMagnum 3000 Stackable Hubs and Concentrators Etsi and NEBS-certified models, -48VDC poweredOrdering Information Network Management OptionsIntroduction Magnum 3012 and 3024 Stackable Hubs Inspecting the Package and ProductProduct Description Magnum 3000 Stackable Hubs Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slot Stacking Magnum 3000sWww . GarrettCom . com Stack Cable3 4 5 6 7 Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slot 4a, Magnum 3012 Hub, Front ViewRear Bonus Slot, Port Modules PMs Included only when PM is factory installed 5c Magnum 3012 internal layout with configured Bonus PortPM Ribbon cable with 16 pin connector Bonus port for optional PM card BPM shownCBL-AUI Features and Benefits, Magnum 3024 and 3012 Hubs Applications Wing B Wing aInstallation and Operation Connecting Ethernet MediaConnecting Twisted Pair RJ-45, Unshielded or Shielded Connecting ThickNet 10BASE5 AUI Connecting ThinNet 10BASE2 BNCConnecting Drop Cable 10BASE5 DTE At regular intervals you must use the color-coded strand on Connecting Fiber Optic SC-type, Snap-OnConnecting Single-Mode Fiber Optic SMF Associated ports at each end of the fiber optic segmentRack-mounting ’cvrOptional RPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TP Introduction Magnum Port ModulesProduct Description, Port Modules BPM-BNC BPM-AUI BPM-TP BPM-FSTRPM-BNC RPM-AUIDirectly Magnum RPM-BNC Www . GarrettCom . com Pin Function RPM-DTE2 AUI Pin Assignments Magnum RPM-DTEJumper Across RPM-FST Fiber ST, Twist-lock ConnectorMagnum RPM-FST 3 kmMagnum RPM-FSC RPM-FSC Fiber SC, Snap-in ConnectorRPM-SMF Single-mode Fiber Magnum RPM-SMFNot used RPM-TP Twisted PairJumper Across Distances Supported 10 KmBPM-BNC Magnum BPM-BNCBPM-AUI BPM-FSTMagnum BPM-FST Environments with maximum Ft., or shielded twisted pair wiringBPM-TP Segment distances up to 100mIntroduction Simple Network Management Protocol Snmp Agents Snmp Agents DescriptionEmbedded Snmp Agent, Model 3000-MB Separate Agent Box, Model 3000-AGT Standard Repeater MIB and ExtensionsWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installation, General Information Installing the Embedded Agent Board, MBRemove Chassis Cover of the hub 3b Magnum 3024, Top View with Cover OffMagnum Snmp Agent Board Set Group # Stack Address Magnum 3024/3012Eight-Position DIP Switch Configuration Table Address\switchAgent Configuration, Embedded Agent and Agent Box Versions Switch # 7 and Switch # 8 are not usedAutomatic Agent IP Address Configuration Manual IP Address ConfigurationPerforming Self Diagnostics Address IP/ Name Bootp IP/NAMEBootp Bootp IP/NAME Community # Names ManagerCommunity Community # Name S Manager Manager Manager # IP/NAME Port CommunityOther Convenience Commands 11/12/93 1145 CrBefore Calling for Assistance When Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Appendix a Warranty Information Shipping and Packaging InformationPower Supply Internal -48VDC Option Appendix B Internal DC Power Supply OptionB1.0 Specifications for Magnum 3000S B3.0 Applications for DC Powered HubsInstallation B4.0This section describes C1.0 Specifications for Magnum 3000S Hubs Appendix C Internal DC Dual-Source Power OptionTroubleshooting B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C3.0 DUAL-SOURCE OPTION, Theory of OperationC5.0 Installation C5.1 UL RequirementsExample Magnum 3024-24VDC or Magnum 3012-125VDC C6.0 Ordering InformationExample Magnum 3012-48VDC C7.0 Operation