GarrettCom Magnum 3000 manual Rack-mounting, ’cvr

Page 27

Magnum 3000 Stackable Hubs

Installation and User Guide (07/06)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

The following data has been collected from component manufacturer’s (HP’s and Siemens’) web sites and catalogs to provide guidance to network designers and installers.

Fiber

Port

Module

RPM-FST,

FSC

RPM-

SMF(ST)

Speed,

 

Std.

Wave

Cable

X’mitr

R’cvr

Worst

Worst*

 

typical

typical*

Std.

Mode

km

-

Size

Output

Sens.

OPB,

distance

 

OPB,

distance

 

fdx

length

m

PT , dB

PR ,dB

dB

Km, fdx

 

dB

Km, fdx

 

 

 

 

 

(hdx)

nm

 

 

 

 

 

 

 

 

10 Mb

Multi-

2

 

62.5/125

-15.0

-31

14

5

 

17

6

850

100/140

-9.5

-31

19.5

5.9

 

23.5

7

FL

mode

(2)

 

 

50/125

-19.5

-31

9.5

3.4

 

13.5

4.8

 

 

 

 

 

 

 

 

 

 

 

 

10 Mb

Single-

10

1300

9/125

-30

-39

7

14

 

13

26

FL

mode

(5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only if the following factors are both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the full-duplex (factory default) setting for 100Mbps fiber ports must be used, and

The worst-case OPB of the fiber link must be greater than the fiber cable’s

passive Attenuation.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

3.1.9Rack-mounting

Installation of a Magnum 3000s Hub in a 19” rack is a simple procedure. The

units are 1U (1.70”) high. When properly installed, the front-mounted LED status indicators should be in plain view and easy to read. Rack-mount installation requires

special 19” rack-mounted brackets and screws

StackableMagnum 3000Hub

GARRETT

(included with each 3000s unit). The brackets attach to the front sides of the Hub,

which is then fastened into a standard 19” RETMA rack.

The 23” brackets and ETSI brackets are also available (optional) for Rack- mounting of Magnum 3000 units. The 23” brackets are more popular in the Telco industry where they are a standard for Central Office Rack-mounting purposes. The 23” brackets are mainly used for larger equipment assemblies in rack mounting frames, and are frequently accessed in operation from both sides.

www . GarrettCom . com

20

Image 27
Contents Magnum Stackable Hubs Trademarks Magnum Stackable Hubs Installation and User GuideContacting GarrettCom, Inc GarrettCom, IncRevisions PrefaceTable of Contents Specifications Magnum 3024, MagnumIntro Simple Ntwrk Mgmt Protocol Snmp AGENTS32 Magnum Line Specifications Magnum 3024, Magnum Packaging DC Power Supply OptionsLED Indicators on Chassis Front WarrantySpecifications Bridge Port Modules BPMs Bonus Ports Specifications Repeater Port Modules RPMs Bonus PortsNetwork Management Options Etsi and NEBS-certified models, -48VDC poweredOrdering Information Magnum 3000 Stackable Hubs and ConcentratorsInspecting the Package and Product Introduction Magnum 3012 and 3024 Stackable HubsProduct Description Magnum 3000 Stackable Hubs Stacking Magnum 3000s Magnum 3024 Hub 24 RJ-45 Ports, One PM bonus port slotWww . GarrettCom . com Cable Stack3 4 5 6 7 4a, Magnum 3012 Hub, Front View Magnum 3012 Hub 12 RJ-45 Ports, One PM bonus port slotRear Bonus Slot, Port Modules PMs 5c Magnum 3012 internal layout with configured Bonus Port Included only when PM is factory installedPM Ribbon cable with 16 pin connector Bonus port for optional PM card BPM shownCBL-AUI Features and Benefits, Magnum 3024 and 3012 Hubs Wing B Wing a ApplicationsInstallation and Operation Connecting Ethernet MediaConnecting Twisted Pair RJ-45, Unshielded or Shielded Connecting ThickNet 10BASE5 AUI Connecting ThinNet 10BASE2 BNCConnecting Drop Cable 10BASE5 DTE Associated ports at each end of the fiber optic segment Connecting Fiber Optic SC-type, Snap-OnConnecting Single-Mode Fiber Optic SMF At regular intervals you must use the color-coded strand on’cvr Rack-mountingOptional BPM-BNC BPM-AUI BPM-TP BPM-FST Introduction Magnum Port ModulesProduct Description, Port Modules RPM-BNC, RPM-AUI, RPM-DTE RPM-FST or FSC, RPM-SMF, RPM-TPRPM-BNC RPM-AUIDirectly Magnum RPM-BNC Www . GarrettCom . com Magnum RPM-DTE RPM-DTE2 AUI Pin Assignments Pin Function3 km RPM-FST Fiber ST, Twist-lock ConnectorMagnum RPM-FST Jumper AcrossMagnum RPM-SMF RPM-FSC Fiber SC, Snap-in ConnectorRPM-SMF Single-mode Fiber Magnum RPM-FSC10 Km RPM-TP Twisted PairJumper Across Distances Supported Not usedMagnum BPM-BNC BPM-BNCBPM-AUI BPM-FSTMagnum BPM-FST Segment distances up to 100m Ft., or shielded twisted pair wiringBPM-TP Environments with maximumIntroduction Simple Network Management Protocol Snmp Agents Snmp Agents DescriptionEmbedded Snmp Agent, Model 3000-MB Standard Repeater MIB and Extensions Separate Agent Box, Model 3000-AGTWww . GarrettCom . com 3 Magnum Snmp Agent Commands Variable Type Installing the Embedded Agent Board, MB Installation, General Information3b Magnum 3024, Top View with Cover Off Remove Chassis Cover of the hubSet Group # Stack Address Magnum 3024/3012 Magnum Snmp Agent BoardSwitch # 7 and Switch # 8 are not used Address\switchAgent Configuration, Embedded Agent and Agent Box Versions Eight-Position DIP Switch Configuration TableAutomatic Agent IP Address Configuration Manual IP Address ConfigurationPerforming Self Diagnostics Community # Names Manager Bootp IP/NAMEBootp Bootp IP/NAME Address IP/ NameManager Manager # IP/NAME Port Community Community Community # Name S Manager11/12/93 1145 Cr Other Convenience CommandsBefore Calling for Assistance When Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging Information Appendix a Warranty InformationB3.0 Applications for DC Powered Hubs Appendix B Internal DC Power Supply OptionB1.0 Specifications for Magnum 3000S Power Supply Internal -48VDC OptionInstallation B4.0This section describes B5.0 Operation Appendix C Internal DC Dual-Source Power OptionTroubleshooting C1.0 Specifications for Magnum 3000S HubsC3.0 DUAL-SOURCE OPTION, Theory of Operation C4.0 Features and Benefits of the DUAL-SOURCE DesignC5.1 UL Requirements C5.0 InstallationC7.0 Operation C6.0 Ordering InformationExample Magnum 3012-48VDC Example Magnum 3024-24VDC or Magnum 3012-125VDC