Magnum 3000 Stackable HubsInstallation and User Guide (07/06)
operations: CPU test, EPROM CRC test, DRAM test, Network Interface Controller test and NVRAM test.
During the configuration process, an ANSI compatible terminal or a PC running ANSI terminal emulation software should be connected (through a null modem cable) to the serial port "P1" located on the rear panel of the Magnum 3000 unit. The terminal characteristics should be set to: 9600 Baud, 8 bit data, no parity, 1 stop bit.
If the agent board (either embedded in a unit, or in a box by itself) is operating properly, the following (example) message will appear on the terminal screen:
Performing Self Diagnostics . . . | (pause for 30 to 60 seconds typically) | |
Garrett Communications Embedded Agent Version 02.05 | (example) | |
Processor 3003 Controller 14 Ethernet Controller 30003003 | (example) | |
Ethernet address 00 00 1A 18 0E 18 | IP address 45.9.0.5 | (example) |
5.4.1Automatic Agent IP Address Configuration.
At power up, the agent software program will search for an IP address in
NVRAM. A legitimate IP address is set into the NVRAM at the factory, permitting the unit or stack when new to automatically go into operation as a
For more complex networks where the IP address is to be set from a server on an existing network, set the NVRAM IP address to a blank using the procedure in "Function Listing, Address" below. Then, at power up when the agent software program does not find an IP address, it will try to get configuration information from a boot server by using the BOOTP protocol. If this attempt fails, it will try RARP protocol. This process may require up to one minute.
Next, the agent automatically determines the configuration of the Magnum 3000 stack by reading the group # addresses of all of the units in the stack. The stacked units, from one to twenty in number which operate as one repeater, will have one repeater agent and its IP address. (Note that a group # address should be set for each unit by using switches on the back of each unit. See Section 4.3, Table 4.3.
5.4.2Manual IP Address Configuration.
If the network does not support BOOTP or RARP, or if you need to manually
change the agent's IP address to a
www . GarrettCom . com