2.4 Installation Environment

Power: Ensure that the installation site’s AC power is stable and within the rated voltage of the external power supply. If the site’s AC power is likely to have spikes or dips, use power line conditioning or an Uninterruptible Power Supply.

Temperature: Observe the unit’s ambient temperature specifications when choosing a location for the unit. Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail. Do not install this unit on top of other hot equipment.

Moisture: Do not expose the unit to rain or moisture. Moisture can damage internal components. Do not install this unit near sources of water.

RS-232 Limitations: Cable length between the POS device and the ProBridge is limited to 50’. Cable length between the ProBridge unit and the DVMRe is also limited to 50’. If the supplied cables are replaced by custom made cables to address distances between components, ensure the cable is manufactured to ANSI standards for RS-232 communication.

RS485 Limitations: If multiple PB3 units are connected to a single DVMRe unit, the distance between the first and last ProBridge unit is limited to 3,000 feet (RS- 485 communications).

2.5 Power

The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use any other power supply with this product. The manufacturer accepts no responsibility for damage caused by the use of any other power supply.

Make sure installation is complete and all connections are made before applying power to the unit.

4310-0007 120VAC Power Supply

Power Supply Input

Voltage: 120 Volt AC

Tolerance: ±10%

Frequency: 60 Hz

Power Supply Output

Voltage: 12 Volt DC

Current: 110mA

Power: 1.3 Watts

Connector: 2.1mm female barrel. Center Positive

Kalatel CBR-PB3-WD

7

0150-0261A

Image 7
Contents Kalatel CBR-PB3-WD ProBridge Receipt Printer Interface Copyright Information Table of Contents 14.1 Factory Service 14.2 Warranty Cable Specifications Warranty and ServiceCompatibility Additional Equipment Provided by InstallerCBR-PB3-WD ProBridge Kalatel CBR-PB3-WD DescriptionKalatel Components Installation SummaryHow to Use this Manual Before You BeginPower Installation Environment4310-0007 120VAC Power Supply Tolerance ±10% Frequency 50 Hz Power Supply Output 4310-0008 220VAC Power SupplyProBridge Diagram Important Switch Assignments Default Factory Dipswitch SettingsDVMRe Triplex Connection DiagramSample Systems Termination Termination SwitchPB3 Physical Installation Detailed Installation StepsAssociating ECR data to a specific camera Configuring the PB3 for POS InterfaceProcess several POS transactions at the Cash Register Kalatel CBR-PB3-WD 0150-0261A Special Functions Demo Simulated Message ModeDisplay Memory Reset Clear Memory Kalatel CBR-PB3-WD 0150-0261A Baud Rate Port 1200 2400 4800 9600 14.4k 19.2k 38.4k TroubleshootingSwitch Setting Up Off = U Down On = DTroubleshooting Guide Dipswitch 5 Camera Assignment Dipswitch Numbers SW1 DipswitchesText to Camera Address SW1 Manual Dipswitch Settings Available Manual Switch ConfigBaud Rate Protocol Kalatel CBR-PB3-WD 0150-0261A Equipment Required HyperTerminal SetupSetting up the ProBridge for HyperTerminal Operation Manual HyperTerminal Configuration Menu Selection 2 Protocol Options q Asynchronous Setup Option 2 Port #2Menus Selection 7 Device Type q Generic Receipt Printer Menu Selection 5 Mode The available selections areMenu Selection 3 Baud Rate Menu Selection 4 Parity11 PB3-POS with DVMRe -CD/CS Units DVMRe-CS/CD SetupCommunicationsRS-232Port 1 ATM Activate Final Testing ProBridge to Triplex DVMRe-CT Cable SpecificationsRJ-45 Connector RJ-45 Connector DB9F ConnectorProBridge to ProBridge Cable Communication Type RS-485 Connector Type RJ45, RJ45RJ45 Connector DB9F Connector DB9F and DB9M ConnectorSpecifications Factory Address Warranty and ServiceFactory Service WarrantyAdvance Replacement Policy