As a troubleshooting tool, this element allows you to verify that the PB3 is able to send messages and have the DVMRe correctly capture data coming from the PB3. In this mode, if text can be received and displayed, yet when attempting to process ECR data fails, then some other problem exists with respect to the ECR connection (cabling) or interface setup.
To access this mode:
| SW1 | |
|
|
|
1 |
| Down |
|
|
|
2 |
| Down |
|
|
|
3 |
| Up |
|
|
|
4 |
| Down |
|
|
|
To exit this mode return the dipswitches to the following position:
| SW1 | |
|
|
|
1 |
| Up |
|
|
|
2 |
| Up |
|
|
|
3 |
| Up |
|
|
|
4 |
| Up |
|
|
|
6.3 Reset – Clear Memory
This is primarily a troubleshooting tool that allows the user to clear the non- volatile memory of all settings. This will restore all factory defaults as a first step to reconfiguring the unit.
To access this mode:
| SW1 | |
|
|
|
1 |
| Down |
|
|
|
2 |
| Down |
|
|
|
3 |
| Down |
|
|
|
4 |
| Down |
|
|
|
Kalatel | 17 |