58. SLAVE JOG RATIO

61. SLAVE PRESET #2

USE PARAMETER #58 TO SET A JOG SPEED WHICH CAN BE TOGGLED IN AND OUT. RANGE OF VALUES: FFFE 7961h to 0001 869Fh

-99,999 to 99,999

(decimal)

Default Value: 0000 00C8h

100 (decimal)

The SLAVE JOG Speed is the speed to which the motor will go when a JOG input is activated on one of the Digital inputs (any of the seven digital inputs may be programmed as a JOG input) when the DFS-1 is in the SLAVE mode. If more than one input is programmed as a JOG input, they must both be present to activate the SLAVE JOG Speed function (the inputs are logically ANDed).

59.EGU TAG SELECT

 

(Parameter 59 not functional at present)

RANGE OF VALUES: 0 TO F

 

0=

UNK

6=

LBS/HR

1=

RPM

7=

PCT

2=

GPM

8=

CFM

3=

FPM

9=

Y/MIN

4=

SPM

10=

M/MIN

5=

LBS-FT

11=

IN/SEC

Default Value: 0000 0000h

0 (decimal)

60.MASTER PRESET #2

USE PARAMETER #60 TO SET A PRESET SPEED WHICH CAN BE TOGGLED IN AND OUT. RANGE OF VALUES: FFFE 7961h to 0001 869Fh

-99,999 to 99,999

(decimal)

Default Value: 0000 00C8h

100 (decimal)

The MASTER PRESET #2 is the speed to which the motor will go when a PRESET #2 input is activated on one of the Digital inputs (any of the seven digital inputs may be programmed as a PRESET #2 input) when the DFS-1 is in the MAS- TER mode. If more than one input is programmed as a PRESET #2 input, they must both be present to activate the MASTER PRESET #2 function (the inputs are logically ANDed).

USE PARAMETER #61 TO SET A

PRESET SPEED WHICH CAN BE TOGGLED IN AND OUT.

RANGE OF VALUES: FFFE 7961h to 0001 869Fh

-99,999 to 99,999

(decimal)

Default Value: 0000 00C8h

100 (decimal)

The SLAVE PRESET #2 is the speed to which the motor will go when a PRESET #2 input is activated on one of the Digital inputs (any of the seven digital inputs may be programmed as a PRESET #2 input) when the DFS-1 is in the SLAVE mode. If more than one input is programmed as a PRESET #2 input, they must both be present to activate the SLAVE PRESET #2 function (the inputs are logically ANDed).

62.CONTACTORDELAY

USE PARAMETER #62 TO SET TIME INTERVAL BETWEEN RUN COMMAND AND INITIAL FIRING OF TRANSISTORS.

RANGE OF VALUES: 0000 0000 to 0000 0028h 0 TO 40 (decimal)

Default Value: 0000 0000h

0 (decimal)

This parameter sets the time interval between the acceptance of a run command and the initial firing of the transistors. If the Contactor Aux input does not become active in this time period, the transistors will not fire and the drive will return to a stop condition. The value of this parameter is in increments of 25ms. See the Additional Info section for examples.

Revised 7/95

DFS-1 Manual

Page 35

POWERTEC Ind. Corp.©

 

 

Page 40