PowerTec DFS-1 manual Response If no errors and unit i.d. does not equal, Dlestxuidackdleetxcsm

Models: DFS-1

1 84
Download 84 pages 52.2 Kb
Page 54
Image 54

Message:

[DLE][STX][UID][CMD][DLE][ETX][CSM]

Response:

If no errors and unit i.d. does not equal 0

[DLE][STX][UID][ACK][DLE][ETX][CSM]

If unit i.d. = 0 (global command) then no response at all but all DIGIMAXes will execute simultaneously.

else

[DLE][STX][UID][NAK][ERR][DLE][ETX][CSM]

Definitions:

[ERR] - Reported Error.

[80]- Unit not in remote mode

[86]- Illegal Command number

Set & Execute Speed (84)

Command: Set & Execute Speed

Description:

This command tells the unit to set the new commanded speed to the value and execute it immediately.

CMD = [84]

UID = [01] - [FF]

Message:

[DLE][STX][UID][CMD][CS4][CS3][CS2][CS1][DLE][ETX][CSM]

Response:

If no errors

[DLE][STX][UID][ACK][DLE][ETX][CSM] else

[DLE][STX][UID][NAK][ERR][DLE][ETX][CSM]

Definitions:

[CS4]..[CS1] - Commanded speed, unsigned long integer

[ERR] - Reported Error.

[80]- Unit not in remote mode

[81]- Illegal speed value

[86]- Illegal Command number Read Parameter (85)

Command: Read Parameter

Description:

This command tells the unit to send the value of the selected parameter.

CMD = [85]

UID = [01] - [FF]

Message:

[DLE][STX][UID][CMD][PRM][DLE][ETX][CSM]

Response:

If no errors

[DLE][STX][UID][ACK][DT4][DT3][DT2]DT1][DLE][ETX][CSM] else

[DLE][STX][UID][NAK][ERR][DLE][ETX][CSM]

Definitions:

[DT4] THRU [DT1] Datum is returned as an long integer.

[PRM] - Parameter number [ERR] - Reported Error

[82]- Illegal parameter number

[86]- Illegal Command number

Write Parameter (86)

Command: Write Parameter

Description:

This command tells the unit to change the value of the selected parameter.

CMD = [86]

UID = [01] - [FF]

Revised 7/95

DFS-1 Manual

Page 49

POWERTEC Ind. Corp.©

 

 

Page 54
Image 54
PowerTec DFS-1 manual Response If no errors and unit i.d. does not equal, Dlestxuidackdleetxcsm, Dlestxuidcmdprmdleetxcsm