25.ANALOG OUTPUT #1 MODE SELECT
USE PARAMETER #25 TO SELECT THE SOURCE OF A SIGNAL AT ANALOG OUTPUT #1.
RANGE OF VALUES: 0000 0000h to 0000 0003h
0 to 4 (decimal) | |
Default Value: 0000 0001h | 1 (decimal) |
Analog Output #1 may be programmed for several modes of operation. The mode affects where the signal at Analog Output #1 comes from. The following modes are provided for:
0000 0000h | Disabled. |
0000 0001h | Actual Speed - Represents the speed |
| of the motor from 0 to parameter #14. |
0000 0002h | Load Output - Represents the load on |
| the motor from 0 to 1500. |
0000 0003h | Analog Output voltage set by |
| communications from parameters #26 |
| and #27. |
0000 0004h | Commanded Speed |
If an undefined mode (...05h through ...1Fh) is selected, Analog Input #1 will be inoperative.
26.ANALOG OUTPUT #1 LOW ENGINEERING UNITS (EGU)
USE PARAMETER #26 TO SELECT THE THRESHOLD OF ANALOG OUTPUT #1 EFFECT. RANGE OF VALUES: FFFE 7961h to 0001 869Fh
Default Value: 0000 0000h | 0 (decimal) |
Parameter #26 sets the point, in EGU’s, at which the Analog Output #1 will be
27.ANALOG OUTPUT #1 HIGH ENGINEERING UNITS (EGU)
USE PARAMETER #27 TO SELECT THE MAXI- MUM ANALOG OUTPUT #1 EFFECT.
RANGE OF VALUES: FFFE 7961h to 0001 869Fh
Default Value: 0000 06D6h | 1750 (decimal) |
If parameter #27 is greater on the absolute scale than #26, voltage at Analog Output #1 will be scaled proportionally from low EGU’s (parameter #26) to +10VDC at the high engineering units (parameter #27).
If #27 is less than #26, then output sense is inverted, i.e., the higher voltage (from
28.ANALOG OUTPUT #2 MODE SELECT
USE PARAMETER #28 TO SELECT THE SOURCE OF A SIGNAL AT ANALOG OUTPUT #2.
RANGE OF VALUES: 0000 0000h to 0000 0003h
0 to 4 (decimal) | |
Default Value: 0000 0000h | 0 (decimal) |
Analog Output #2 is a general purpose analog output which may be programmed for one of several modes of operation. The mode defines the origin of the signal at Analog Output #2. The following modes are provided for:
0000 0000h | Disabled. |
0000 0001h | Actual Speed - Represents the speed |
| of the motor from 0 to parameter #14. |
0000 0002h | Load Output - Represents the load on |
| the motor from 0 to 1500. |
0000 0003h | Analog Output voltage set by commu- |
| nications from parameters #29 and |
| #30. |
0000 0004h | Commanded Speed |
If an undefined mode ...05h through ...1Fh is selected, Analog Input #2 will be inoperative.
Revised 7/95 | Page 27 | |