GE Series 90-70 manual GFK-0644A

Page 26

3

4.If you are using version 4 of Logicmaster, press F1 (vme) to display the catalog list shown below. Select Foreign VME from the list.

If you are using version 3 of Logicmaster instead press F2 (vme) to display the catalog list. From the list, select Foreign VME (no interrupt).

5.No further configuration is required; press Rack (Shift±F1) or the Escape key to return to the rack display.

22

Series 90t-70 I/O Link Interface Module User's Manual ± February 1993

GFK-0644A

Image 26
Contents GE Fanuc Automation GFL±002 We Welcome Your Comments and Suggestions Content of this ManualRelated Publications Contents Chapter Introduction System OverviewMaster or Slave Operation Application Software Module Description LEDsSerial Ports Module SpecificationsReset Pushbutton Cable Types for the I/O Link CatalogNumberCable Lengths on the I/O Link Optical Adapter Operation of the I/O Link Input and Output DataData Sent by the Master Data Returned by SlavesInputs and Outputs Hold Last State Faults on the I/O Link Diagnostics Link ControlComplete the program logic for the I/O Link Module Install the module and complete the I/O LinkGetting Started Chapter Installation Installing the I/O Link Interface Module in the RackRemoving the I/O Link Interface Module from the Rack LED Name LED Status IndicationLink Module Used as a Master Connecting the I/O Link Interface Module to Other DevicesPorts on the I/O Link Module Order of the Devices on the Link Serial Port Pin AssignmentsLink Module Used as a Slave Cable Diagram, No Optical Adapter Cable Connections Optical Adapter InstallationCable Diagram, Electrical Cable to Optical Adapter Chapter Logicmaster 90-70 Configuration Configuration StepsGFK-0644A Chapter Programming Guide OverviewSelecting a Program Block Adding the Program Block Logic to an Application ProgramExample Call Instruction Using Multiple Calls to the Program BlockCalling the Program Block Program %P References for the I/O Link Program Blocks 3rdModule 4thModuleUsing Nicknames for the %P References Global %G References for the I/O Link Program BlocksConfiguring I/O Links Configuration Logic, ExampleConfiguration Guidelines Specify the Number of I/O Link ModulesControlling the I/O Link Module Set Master or Slave Mode bitReset or Stop bit Start/Restart bitDisable or Enable the Input Update bit Disable or Enable the Output Update bitMonitor Communications Status bit Monitoring Link OperationMonitor the Module bit Monitor for an Invalid Configuration or Link Fault bit Monitor for Link Failure bitError Codes Troubleshooting Error Description RecommendedAction CodeConfiguration Error Codes Index GFK-0644A Index