Configuration Error Codes

Error Codes 10 to 91, listed below, describe configuration errors. If the I/O Interface

Module is being used as a slave, only Error Codes 10, 11, 12, 28, and 44 are used.

Error

Description of Error

RecommendedAction

Error

DescriptionofError

RecommendedAction

Code

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

10

Invalid rack ID

Must be in range 0±7

44

Dev. 0, invalid %Q

Must not be greater

 

 

 

 

 

startingaddress

thanmaximumI/Odata

 

 

 

 

45

Dev. 1

 

º

length.

 

 

 

 

46

Dev. 2

 

º

 

 

 

 

 

47

Dev. 3

 

º

 

 

 

 

 

48

Dev. 4

 

º

 

 

 

 

 

49

Dev. 5

 

º

 

 

 

 

 

50

Dev. 6

 

º

 

 

 

 

 

51

Dev. 7

 

º

 

 

 

 

 

52

Dev. 8

 

º

 

 

 

 

 

53

Dev. 9

 

º

 

 

 

 

 

54

Dev. 10

º

 

 

 

 

 

55

Dev. 11

º

 

 

 

 

 

56

Dev. 12

º

 

 

 

 

 

57

Dev. 13

º

 

 

 

 

 

58

Dev. 14

º

 

 

 

 

 

59

Dev. 15

º

 

 

 

 

 

 

 

11

Invalid slot ID

Must be in range 2±9

60

Link devices not de-

All data length register

 

 

 

 

 

fined with consecu-

values must be 0, fol-

 

 

 

 

 

tiveaddresses

lowing the first occur-

 

 

 

 

 

 

 

 

rence of 0.

 

 

 

 

 

 

12

Dev. 0, Invalid data

Must be 0, 32, or 64.

61

Dev. 0, configured

Link doesn't operate.

 

length

 

 

 

but not responding.

 

13

Dev. 1

º

 

62

Dev. 1

 

º

Link continues to oper-

14

Dev. 2

º

 

 

 

 

 

ate with dev. 0

15

Dev. 3

º

 

 

 

 

 

 

16

Dev. 4

º

 

63

Dev. 2

 

º

Link continues to oper-

17

Dev. 5

º

 

64

Dev. 3

 

º

ate with previous de-

18

Dev. 6

º

 

65

Dev. 4

 

º

vices.

19

Dev. 7

º

 

66

Dev. 5

 

º

º

20

Dev. 8

º

 

67

Dev. 6

 

º

º

21

Dev. 9

º

 

68

Dev. 7

 

º

º

22

Dev. 10

º

 

69

Dev. 8

 

º

º

23

Dev. 11

º

 

70

Dev. 9

 

º

º

24

Dev. 12

º

 

71

Dev. 10

º

º

25

Dev. 13

º

 

72

Dev. 11

º

º

26

Dev. 14

º

 

73

Dev. 12

º

º

27

Dev. 15

º

 

74

Dev. 13

º

º

 

 

 

 

75

Dev. 14

º

º

 

 

 

 

76

Dev. 15

º

º

 

 

 

 

 

 

28

Dev. 0, invalid %I

Must not be greater

77

1 extra(undefined)

 

 

startingaddress

thanmaximumI/Odata

 

device on the link

 

29

Dev. 1

º

length.

 

2 extra(undefined)

 

30

Dev. 2

º

 

78

 

31

Dev. 3

º

 

 

devices on the link

 

32

Dev. 4

º

 

79

3

º

 

 

33

Dev. 5

º

 

80

4

º

 

 

34

Dev. 6

º

 

81

5

º

 

 

35

Dev. 7

º

 

82

6

º

 

 

36

Dev. 8

º

 

83

7

º

 

 

37

Dev. 9

º

 

84

8

º

 

 

38

Dev. 10

º

 

85

9

º

 

 

39

Dev. 11

º

 

86

10

º

 

 

40

Dev. 12

º

 

87

11

º

 

 

41

Dev. 13

º

 

88

12

º

 

 

42

Dev. 14

º

 

89

13

º

 

 

43

Dev. 15

º

 

90

14

º

 

 

 

 

 

 

91

15

º

 

 

 

 

 

 

 

 

 

 

 

GFK±0644

Chapter 4 Programming Guide

35

Image 39
Contents GE Fanuc Automation GFL±002 Content of this Manual Related PublicationsWe Welcome Your Comments and Suggestions Contents System Overview Chapter IntroductionMaster or Slave Operation Application Software LEDs Module DescriptionModule Specifications Reset PushbuttonSerial Ports CatalogNumber Cable Types for the I/O LinkCable Lengths on the I/O Link Optical Adapter Input and Output Data Operation of the I/O LinkData Returned by Slaves Data Sent by the MasterInputs and Outputs Hold Last State Faults on the I/O Link Link Control DiagnosticsInstall the module and complete the I/O Link Getting StartedComplete the program logic for the I/O Link Module Installing the I/O Link Interface Module in the Rack Chapter InstallationLED Name LED Status Indication Removing the I/O Link Interface Module from the RackConnecting the I/O Link Interface Module to Other Devices Ports on the I/O Link ModuleLink Module Used as a Master Serial Port Pin Assignments Link Module Used as a SlaveOrder of the Devices on the Link Cable Diagram, No Optical Adapter Optical Adapter Installation Cable Diagram, Electrical Cable to Optical AdapterCable Connections Configuration Steps Chapter Logicmaster 90-70 ConfigurationGFK-0644A Overview Chapter Programming GuideAdding the Program Block Logic to an Application Program Selecting a Program BlockUsing Multiple Calls to the Program Block Calling the Program BlockExample Call Instruction 3rdModule 4thModule Program %P References for the I/O Link Program BlocksGlobal %G References for the I/O Link Program Blocks Using Nicknames for the %P ReferencesConfiguration Logic, Example Configuring I/O LinksSpecify the Number of I/O Link Modules Configuration GuidelinesStart/Restart bit Set Master or Slave Mode bitReset or Stop bit Controlling the I/O Link ModuleDisable or Enable the Output Update bit Disable or Enable the Input Update bitMonitoring Link Operation Monitor the Module bitMonitor Communications Status bit Monitor for Link Failure bit Monitor for an Invalid Configuration or Link Fault bitError Description RecommendedAction Code Error Codes TroubleshootingConfiguration Error Codes Index GFK-0644A Index