When a controlled shutdown is initiated from the OFFLINE/RESET switch, you have 60 seconds from the time the CPU starts alternately flashing amber/off until the device automatically restarts.
Note: The only safe time to remove a
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
Caution: This method of shutting down a DFE module is not recommended except as a last resort, because all processes currently running on the module will be interrupted, resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE. Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del módulo en funcionamiento, lo que podría resultar pérdidas de frames.
To reset a DFE‐Gold module without it performing an orderly shutdown routine,
press and hold the OFFLINE/RESET switch for approximately 6 seconds.
Removing any DFE‐Gold module from the chassis before it has been shut down is not recommended. The only safe time to remove a module from the chassis is after the completion of a shutdown and the management LED is alternately flashing amber/off.