Installing Optional XFPs
Installing Optional XFPs
This section describes how to install XFPs in port slots 25 and 26. It is recommended that you install any options before installing the switch.
Warning:
Advertencia: Los XFPs de fibra optica usan lasers de clase 1. No se debe usar instrumentos opticos para ver la potencia laser. El uso de los instrumentos opticos para ver la potencia laser incrementa el riesgo a los ojos. Cuando vean el puerto de la potencia optica, la corriente debe ser removida del adaptador de la red.
Warnhinweis: XFPs mit
Caution: Carefully follow the instructions in this manual to avoid damaging the XFP and switch.
The XFP and switch are sensitive to static discharges. Use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could result in damage to the XFP and switch. Always leave the XFP in the antistatic bag or an equivalent antistatic container when not installed.
Precaución: Siga las instrucciones del manual para no dañar el XFP ni del aparato, puesto que son muy sensible a las descargas de electricidad estática. Utilice la pulsera antiestática y tome todas las precauciones necesarias durante este procedimiento. Si no lo hace, podría dañar el XFP o del aparato. Mientras no esté instalado, mantenga el XFP en su bolsa antiestática o en cualquier otro recipiente antiestático.
Preparation
Before installing the XFP, proceed as follows:
1.Before removing the XFP from the antistatic packaging, it is recommended that you use an antistatic wrist strap (not supplied) to prevent damage from static discharge. To use the wrist strap, refer to the instructions provided with your antistatic wrist strap.
2.Remove the XFP from its packaging.
3.If there is a protective dust cover (see 5 in Figure 3‐1) in the XFP connector, do not remove it at this time.
SecureStack C2 Installation Guide