Troubleshooting Checklist
Figure 4-2 LANVIEW LEDs (continued)
LED | Color | State | Recommended Action | |
|
|
|
|
|
Link/ | Off | 1. | No link. | None. |
Activity |
| 2. | No activity or port in standby. | None. |
|
| |||
|
|
|
| |
| Green | Solid. Port is linked, but the interface is not | None. | |
|
| receiving any traffic. |
| |
|
|
|
| |
|
| Blinking. Port is linked and traffic is being | None. | |
|
| received or transmitted by the interface. |
| |
|
|
|
|
|
Troubleshooting Checklist
If the device is not working properly, refer to Table 4‐1 for a checklist of problems, possible causes, and recommended actions to resolve the problem.
Table
Problem | Possible Cause | Recommended Action | |
|
|
| |
All LEDs are OFF. | Loss of power. | Ensure that the switch was installed properly according to | |
|
| the installation instructions in Chapter 3. | |
|
| Ensure that the power cords are connected properly to an | |
|
| active power source that meets the AC input specifications | |
|
| for this switch. | |
|
| Ensure that the AC power cord is not damaged. Replace the | |
|
| power cord with a known good one. | |
|
|
| |
No local | Incorrect terminal setup. | Refer to the SecureStack C2 Configuration Guide for proper | |
management |
| setup procedures. | |
startup screen. |
|
| |
Improper Console cable | Refer to Appendix A for proper Console port pinouts. | ||
| |||
| pinouts. |
| |
|
|
| |
| Corrupt firmware image, or | If possible, attempt to download the image to the device | |
| hardware fault. | again. Refer to the SecureStack C2 Configuration Guide for | |
|
| details. | |
|
|
| |
Cannot navigate | Improper Community Names | Refer to the SecureStack C2 Configuration Guide for the | |
beyond startup | Table. | Community Names Table setup. | |
screen. |
|
|
SecureStack C2 Installation Guide