Responding to System Events

INVERTER MESSAGES - ALARMS

INVERTER MESSAGES - NOTICES

 

 

 

Over Temperature Shutdown

Battery Not Charged

 

 

Clear Battery Not Charged

 

 

 

100% Overload Shutdown

Bypass is Not Available

 

 

Bypass is Available

 

 

 

125% Overload Shutdown

Input Breaker Open

 

 

 

Bypass Cont. (K2) Failure

Inv. Logic Power Failure

 

 

Clear Inv. Logic Pwr Fail.

 

 

 

Bypass Cont. (K4) Failure

Phase A Current Limit

 

 

Phase B Current Limit

 

 

Phase C Current Limit

 

 

 

Bypass Control Failure

Load Transferred to Bypass

 

 

 

Inverter Cont. (K3) Failure

 

 

 

 

Inverter Failure

 

 

 

 

Load Off

 

 

 

 

Inverter Cont. (K3) Open

 

 

 

 

Bypass Cont. (K4) Failure

 

 

 

 

Bypass Mode

Inverter On

Normal Mode

Inverter Off

 

 

 

Keyswitch On

Bypass Contactor (K2) Closed

 

 

Bypass Contactor (K2) Open

 

 

 

Inverter Commanded On

Total Battery Discharge

Inverter Commanded Off

 

 

 

 

 

 

Bypass Contactor (K4) Closed

 

 

Bypass Contactor (K4) Opened

 

 

 

 

 

Input Breaker (CB1) Closed

 

 

Input Breaker (CB1) Opened

 

 

 

 

 

Inverter Contactor (K3) Closed

 

 

Inverter Contactor (K3) Opened

 

 

 

 

 

Inverter Shutdown

 

 

 

 

 

Inverter Normal

 

 

 

 

 

Load Transferred to Bypass

 

 

 

 

 

Auto Mode

 

 

 

10-2

EATON Powerware® 9315 UPS (200–300 kVA) Operation Manual S 164201036 Rev F powerware.com

Image 76
Contents Page Important Safety Instructions Table of Contents Starting and Stopping the UPS Maintaining the UPS System List of Figures Introduction Conventions Used in This ManualFor More Information Getting HelpSafety Warnings Getting StartedTypical Powerware 9315 UPS System Typical Powerware 9315 UPS SystemPower Processing Unit PPU Looking Inside the UPSUPS Standard Features Monitor PanelControl Panel Communication BaysOptions and Accessories Power Distribution Module LV models only Upgrade CapabilityRemote Monitor Panel Relay Interface ModuleModem Output TransformerCustomer Convenience Outlet Symbols, Controls, and Indicators Normal Mode Understanding UPS OperationPath of Current Through the UPS in Normal Mode Bypass Mode Path of Current Through the UPS in Bypass ModeBattery Mode Path of Current Through the UPS in Battery ModeMonitoring and Controlling UPS Operation Location of the Monitor Panel and the Control PanelThis page intentionally left blank Using the Control Panel Starting and Stopping the UPSTo Place the UPS in Normal Mode To Shut Down the UPS from Normal Mode To Start the UPS in Bypass ModeThis page intentionally left blank Using the Monitor Panel UPS Monitor PanelUsing the LCD Screen System Normal 04 MAY 142345 AlarmAdjusting the Contrast Using the ButtonsUsing the Load Off Button Reading the Status Indicators Using the Menu OptionsShows the Load Amps Meters screen Load Amps Meters Screen Event History Log Screen Active System Events Screen Unit Statistics Screen Mimic Screen Time Setup Screen 10. Setup Serial Port 1 Screen Using Features and Options Building Alarm MonitoringSummary Alarm Contacts Summary Alarm ContactsRemote Monitor Panel Remote Monitor PanelOptional Monitoring Accessories Battery Cabinets External Battery DisconnectRelay Interface Module UPS AvailableSupervisory Contact Module On GeneratorThis page intentionally left blank Communication Locating the Communication BaysLocation of Communication Bays on the UPS Powerware 9315 Slot CardsLanSafe Power Management Software Connecting Equipment to a Serial PortPin Assignments for Port 1 DB-9 Pin Assignments for Port 2 DB-25 Configuring the Serial Ports Setup Serial Port 1 ScreenMode RateDefault Settings Data/StopHandshaking SaveTerminal Mode Printing Selected InformationEntire Log Ctrl+P Event History LogMeters Printout Ctrl+M System MetersBattery Test Printout Ctrl+B System Information Printout Ctrl+ASystem Configuration Mode Main Menu System ConfigurationProgram Building Alarms Enable/Disable Default Functions Customize Alarm Messages Change Password Adjust Output VoltageProgram Unit Name Battery Test Setup WK DAY MON HrmnCalibration Mode Computer ModeRemote Monitor Mode Modify Low Battery TimeRemote Notification This page intentionally left blank Important Safety Instructions Maintaining the UPS SystemPerforming Preventive Maintenance E R T I S S E M E N TMaintenance Training This page intentionally left blank Product Specifications Model NumbersSystem Output Battery Specifications This page intentionally left blank Responding to System Events System Event HornsSystem Event Lights System Event Messages10-2 Rectifier Messages Alarms Rectifier Messages Notices Monitor Panel Alarms Monitor Panel Notices Using the Load OFF Button Resetting the UPS System after Load Off Warranty Limited Factory Warranty for THREE-PHASE Powerware ProductsWarranty Page 164201036F