Emerson Process Management MSL600 Before Operating this Device the Manual should be Read Fully

Page 5

Installation, Operation & Maintenance Manual

IP262/Z0, Rev. AB

February 2012

MSL600

(i)Safety precautions

BEFORE OPERATING THIS DEVICE THE MANUAL SHOULD BE READ FULLY

The following safety precautions should be observed before using this product or working on the attached cables.

￿This MSL600 product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read the operating information carefully before using the product.

￿The types of product users are:

Responsible body: This is the individual or group responsible for the use and maintenance of equipment, and for ensuring that operators are adequately trained. Operators use the product for its intended function. They should not be allowed access to the electrical connections within the control box, and would normally only operate the external keypad and monitor the display.

Maintenance personnel perform routine procedures on the product to keep it operating, for example, checking the line voltage or checking electrical connections, replacing mains fuses etc. Otherwise, only service personnel should perform them.

Service personnel are trained to work on live circuits, and perform safe installations and repairs of products. Only properly trained service personnel may perform installation and service procedures. There are no user serviceable parts on the main PCB section of the MSL600 product.

￿Users of this product must be protected from electric shock at all times. The responsible body must ensure that users are prevented access and/or insulated from every connection point. Product users must be trained to protect themselves from the risk of electric shock.

￿Before operating an instrument, make sure the line cord is connected to a properly grounded power receptacle. Inspect the connecting cables for possible wear, cracks, or breaks before each use. When fuses are used in a product, replace with same type and rating for continued protection against fire hazard.

￿Chassis connections must only be used as shield connections for measuring circuits, NOT as safety earth ground connections.

￿Standard fuses, with applicable national safety approvals, may be used if the rating and type are the same. If you are unsure about the applicability of a replacement component, call a MOBREY office for information. Only use the MSL600 with the sensor supplied or Mobrey agreed replacement. The unit will not necessarily work with apparently equivalent sensor units.

￿To clean the instrument, use a damp cloth or mild, water based cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the inside of the instrument or allow liquids to enter or spill on the instrument.

￿WARNING - If this equipment is used in a manner not specified by Mobrey, the protection provided may be impaired. The MSL600 is regarded as permanently installed equipment and as such a switch or circuit breaker must be included in the installation. This should be in close proximity to the equipment, it should be marked as the disconnecting device, and it should disconnect both current carrying conductors.

￿A protective earth should be used for all applications.

￿The normal application of the MSL600 requires it to be mounted on a water handling plant. The installation point and power cables associated with the MSL600 must be such that tank overflow, local flooding or pump failure do not cause these to be submerged or subject to flows of water. Sensor and sensor cabling can be submerged without hazard to equipment operators when correctly connected as described in this manual.

Explanation of symbols: The IEC Protective Earth Symbol is:

CHECK THAT THE POWER SUPPLY IS SUITABLE BEFORE SWITCHING POWER ON.

Internal adjustments can select mains 115 Volts AC power, which makes the equipment unsuitable for 230V AC supplies. Check the 2 voltage selection switches compared with the available power supply.

Page 5

Image 5
Contents MSL600 Installation, Operation & Maintenance Manual Contents MSL600 12.2 12.1Before Operating this Device the Manual should be Read Fully About this Manual About the MSL600Self-cleaning Important MSL600 featuresHuman Machine Interface Mounting bracketLocation As a systemRotating bridge Application planningCircular clarifiers Static bridge Rectangular clarifiersPreliminary checks InstallationLocation Mounting bracket attachmentAttaching the MSL600 Installing the bracket on the bridgeMSL600 mounting Transducer connections Power and other electrical connectionsExternal connection terminals Cable extension Display ProgrammingKeypad and Menu Navigation Contrast viewing angle controlOn-line/Off-line SecurityTank depth Bottom reference Quick start parametersDetermination of tank depth Transducer self-cleaningMA current output parameters Current output adjustTransducer out-of-water time AlarmRelay parameters Digital input Menu structure Detailed operationMain menu item Menu Item DescriptionScrolling Direct accessParameter editing Main menu parameters Installation parametersApplication parameters Description P240 De-sludge parametersStart On P250 Stop On P251Start Time P253 Stop If P252Interval P254 Max Retries P257MA output parameters Cleaning parameters4 0/4-20mA P403 Alarm Action P402Table B Relay Parameter numbers Relay RL1 mode P410 and RL2 mode P420Alarm mode relay RL1 and RL2 parameters P540 to Set point mode relay RL1 and RL2 Fault mode relay RL1 and RL2 parameters P560 to P570De-sludge mode relay RL1 and RL2 On mode relay RL1 and RL2Relay On and Off Points Display parameters HMIRelay overrides Min ON, Max ON, and Min OFF HMI upper, middle, and lower display optionsClear Profile Backlight On/Off P575Clear Trend Logging parameters Low Mem Alarm P593Log Interval P590 Fast log P591Engineering parameters Parameter values Default Min Max 128 10241 Alg. Select P620 Common algorithm parameters P621 to P629Parameter values Default Min Max 9999 Upr S-nat Temp P625 Parameter values Default Min Max 100 Top Blanking P623Default Min Max +85 105 185 Noise Alrm Lev P622Default metric m/s Default Min Max +85 185 SoS constant P627Lwr S-nat Temp P626 Bottom Blanking P628Municipal 1 parameters P630 to P637 Parameter values Default Min Max Lost Echo Rnge P633Significance P630 Sharp Echo Reject P631Parameter values Default Min Max Lost Echo Time P637 Parameter values Default Min Max Dirty Mult P636Parameter values Default Min Max 255 Noise SD Mult P635Municipal 2 parameter P640 Parameter values Default Min Max 100Threshld Offset P640 Threshold level = Threshld Offset P640 + Noise Level D834System parameters Load Defaults functionAuto Cycle function Display testComms parameters P710 to P716 Settings parameters P730 to P737 and Base Units selectionFixed parameters D750 to D753 PIN parameter P740Readings parameters D800 to D834 Readings and diagnostics parametersDiagnostics parameters D835 to D852 Min Xdr Temp D852 Speed of Sound D850Max Xdr Temp D851 Troubleshooting MaintenanceTechnical reference Transmit pulse and echo processingSub-menu Level Parameter Title Par No Main Menu Option Programming chartProgramming chart … Direct 12.1 MSL600 SpecificationModel No Outputs12.2 MSL603 transducer WeightAdditional specification notes MSL600 Bridge mounted unit Dimensional drawingsMSL600 and MSL603 assembly Fitting instructions MSL603 transducer cable extensionParts required MSL600 MSL600 Emerson Process Management Rosemount Measurement