Emerson Process Management MSL600 manual 12.1, 12.2

Page 4

 

Installation, Operation & Maintenance Manual

 

 

IP262/Z0, Rev. AB

MSL600

February 2012

7.8.4

Low Mem Alarm - P593

36

7.9

Engineering parameters

37

7.9.1

Alg. Select – P620

37

7.9.2

Common algorithm parameters P621 to P629

37

7.9.3

Municipal 1 parameters P630 to P637

40

7.9.4

Municipal 2 parameter P640

42

7.10

System parameters

43

7.10.1

AUTO CYCLE function

43

7.10.2

DISPLAY test

43

7.10.3

Current Output test parameters P700 to P702

43

7.10.4

LOAD DEFAULTS function

43

7.10.5

COMMS parameters P710 to P716

44

7.10.6

SETTINGS parameters P730 to P737 and BASE UNITS selection

44

7.10.7

PIN parameter P740

45

7.10.8

FIXED parameters D750 to D753

45

7.11

Readings and diagnostics parameters

46

7.11.1

Readings parameters D800 to D834

46

7.11.2

Diagnostics parameters D835 to D852

47

8.

Technical reference

49

8.1

Transmit pulse and echo processing

49

9.

Maintenance

49

10.

Troubleshooting

49

11.

Programming chart

50

12.

Specification

53

12.1

MSL600

53

12.2

MSL603 transducer

54

13.

Dimensional drawings

55

14.

MSL603 transducer cable extension

57

Figures and tables

 

Figure (1): MSL600 system architecture

9

Figure (2): Circular clarifiers – Rotating bridge

10

Figure (3): Circular clarifiers - Static bridge

11

Figure (4): Rectangular clarifiers

11

Figure (5): MSL600 mounting

14

Figure (6): Transducer cable wiring

15

Figure (7): External connection terminals

16

Figure (8): The LCD display layout

18

Figure (9): Keypad layout

19

Figure (10): Tank depth parameter

21

Figure (11): Menu structure

26

Figure (12): MSL600 Bridge mounted unit

53

Figure (13): MSL600 and MSL603 assembly

54

Table (A): Connection descriptions reading from left to right (all via M20 cable glands)

16

Table (B): Relay Parameter numbers

32

Page 4

Image 4
Contents Installation, Operation & Maintenance Manual MSL600Contents MSL600 12.1 12.2Before Operating this Device the Manual should be Read Fully About the MSL600 About this ManualImportant MSL600 features Self-cleaningHuman Machine Interface Mounting bracketAs a system LocationCircular clarifiers Application planningRotating bridge Rectangular clarifiers Static bridgeInstallation Preliminary checksLocation Mounting bracket attachmentInstalling the bracket on the bridge Attaching the MSL600MSL600 mounting Power and other electrical connections Transducer connectionsExternal connection terminals Cable extension Programming DisplayContrast viewing angle control Keypad and Menu NavigationSecurity On-line/Off-lineQuick start parameters Tank depth Bottom referenceTransducer self-cleaning Determination of tank depthCurrent output adjust MA current output parametersRelay parameters AlarmTransducer out-of-water time Digital input Detailed operation Menu structureMain menu item Menu Item DescriptionParameter editing Direct accessScrolling Application parameters Installation parametersMain menu parameters De-sludge parameters Description P240Start On P250 Stop On P251Stop If P252 Start Time P253Interval P254 Max Retries P257Cleaning parameters MA output parametersAlarm Action P402 4 0/4-20mA P403Alarm mode relay RL1 and RL2 parameters P540 to Relay RL1 mode P410 and RL2 mode P420Table B Relay Parameter numbers Fault mode relay RL1 and RL2 parameters P560 to P570 Set point mode relay RL1 and RL2De-sludge mode relay RL1 and RL2 On mode relay RL1 and RL2Display parameters HMI Relay On and Off PointsRelay overrides Min ON, Max ON, and Min OFF HMI upper, middle, and lower display optionsClear Trend Backlight On/Off P575Clear Profile Low Mem Alarm P593 Logging parametersLog Interval P590 Fast log P591Parameter values Default Min Max 128 1024 Engineering parameters1 Alg. Select P620 Common algorithm parameters P621 to P629Parameter values Default Min Max 100 Top Blanking P623 Parameter values Default Min Max 9999 Upr S-nat Temp P625Default Min Max +85 105 185 Noise Alrm Lev P622Default Min Max +85 185 SoS constant P627 Default metric m/sLwr S-nat Temp P626 Bottom Blanking P628Parameter values Default Min Max Lost Echo Rnge P633 Municipal 1 parameters P630 to P637Significance P630 Sharp Echo Reject P631Parameter values Default Min Max Dirty Mult P636 Parameter values Default Min Max Lost Echo Time P637Parameter values Default Min Max 255 Noise SD Mult P635Parameter values Default Min Max 100 Municipal 2 parameter P640Threshld Offset P640 Threshold level = Threshld Offset P640 + Noise Level D834Load Defaults function System parametersAuto Cycle function Display testSettings parameters P730 to P737 and Base Units selection Comms parameters P710 to P716PIN parameter P740 Fixed parameters D750 to D753Readings and diagnostics parameters Readings parameters D800 to D834Diagnostics parameters D835 to D852 Max Xdr Temp D851 Speed of Sound D850Min Xdr Temp D852 Maintenance TroubleshootingTechnical reference Transmit pulse and echo processingProgramming chart Sub-menu Level Parameter Title Par No Main Menu OptionProgramming chart … Direct Specification 12.1 MSL600Model No OutputsAdditional specification notes Weight12.2 MSL603 transducer Dimensional drawings MSL600 Bridge mounted unitMSL600 and MSL603 assembly Parts required MSL603 transducer cable extensionFitting instructions MSL600 MSL600 Emerson Process Management Rosemount Measurement