Emerson Process Management MSL600 12.2 MSL603 transducer, Weight, Additional specification notes

Page 54

Installation, Operation & Maintenance Manual

IP262/Z0, Rev. AB

MSL600

 

February 2012

Weight

 

 

Enclosure & compressor housing

7.0 Kg /

15.4 lbs

Transducer & mounting bracket

12.0 Kg

/ 26.4 lbs

Approvals

CE, LVD, EMC

Max Altitude

2000m

 

Max Humidity

95% RH

 

Pollution Degree

2-1EC664

Additional specification notes:

 

 

Programming menu using Mobrey HMI.

 

 

Sludge blanket level from bottom of the clarifier.

Icon enunciators display the relay status.

The display gives a graphical presentation of sludge profile through the clarifier.

A trend graph indicates the sludge level for the last 12 hour(s).

The MSL600 has a single red LED to indicate power on. This LED flashes on as the transducer pulses. Continuous On = fault

12.2 MSL603 transducer

IP Rating

IP68 / Type 6P

Material

Ceramic face, PTFE nozzle, UPVC body

Cable

Alpha xtra-guard 4 P/N 45272, 10 metres

Page 54

Image 54
Contents Installation, Operation & Maintenance Manual MSL600Contents MSL600 12.1 12.2Before Operating this Device the Manual should be Read Fully About the MSL600 About this ManualHuman Machine Interface Important MSL600 featuresSelf-cleaning Mounting bracketAs a system LocationApplication planning Circular clarifiersRotating bridge Rectangular clarifiers Static bridgeLocation InstallationPreliminary checks Mounting bracket attachmentInstalling the bracket on the bridge Attaching the MSL600MSL600 mounting Power and other electrical connections Transducer connectionsExternal connection terminals Cable extension Programming DisplayContrast viewing angle control Keypad and Menu NavigationSecurity On-line/Off-lineQuick start parameters Tank depth Bottom referenceTransducer self-cleaning Determination of tank depthCurrent output adjust MA current output parametersAlarm Relay parametersTransducer out-of-water time Digital input Main menu item Detailed operationMenu structure Menu Item DescriptionDirect access Parameter editingScrolling Installation parameters Application parametersMain menu parameters Start On P250 De-sludge parametersDescription P240 Stop On P251Interval P254 Stop If P252Start Time P253 Max Retries P257Cleaning parameters MA output parametersAlarm Action P402 4 0/4-20mA P403Relay RL1 mode P410 and RL2 mode P420 Alarm mode relay RL1 and RL2 parameters P540 toTable B Relay Parameter numbers De-sludge mode relay RL1 and RL2 Fault mode relay RL1 and RL2 parameters P560 to P570Set point mode relay RL1 and RL2 On mode relay RL1 and RL2Relay overrides Min ON, Max ON, and Min OFF Display parameters HMIRelay On and Off Points HMI upper, middle, and lower display optionsBacklight On/Off P575 Clear TrendClear Profile Log Interval P590 Low Mem Alarm P593Logging parameters Fast log P5911 Alg. Select P620 Parameter values Default Min Max 128 1024Engineering parameters Common algorithm parameters P621 to P629Default Min Max +85 105 185 Parameter values Default Min Max 100 Top Blanking P623Parameter values Default Min Max 9999 Upr S-nat Temp P625 Noise Alrm Lev P622Lwr S-nat Temp P626 Default Min Max +85 185 SoS constant P627Default metric m/s Bottom Blanking P628Significance P630 Parameter values Default Min Max Lost Echo Rnge P633Municipal 1 parameters P630 to P637 Sharp Echo Reject P631Parameter values Default Min Max 255 Parameter values Default Min Max Dirty Mult P636Parameter values Default Min Max Lost Echo Time P637 Noise SD Mult P635Threshld Offset P640 Parameter values Default Min Max 100Municipal 2 parameter P640 Threshold level = Threshld Offset P640 + Noise Level D834Auto Cycle function Load Defaults functionSystem parameters Display testSettings parameters P730 to P737 and Base Units selection Comms parameters P710 to P716PIN parameter P740 Fixed parameters D750 to D753Readings and diagnostics parameters Readings parameters D800 to D834Diagnostics parameters D835 to D852 Speed of Sound D850 Max Xdr Temp D851Min Xdr Temp D852 Technical reference MaintenanceTroubleshooting Transmit pulse and echo processingProgramming chart Sub-menu Level Parameter Title Par No Main Menu OptionProgramming chart … Direct Model No Specification12.1 MSL600 OutputsWeight Additional specification notes12.2 MSL603 transducer Dimensional drawings MSL600 Bridge mounted unitMSL600 and MSL603 assembly MSL603 transducer cable extension Parts requiredFitting instructions MSL600 MSL600 Emerson Process Management Rosemount Measurement