Emerson Process Management MSL600 manual Direct

Page 52

Installation, Operation & Maintenance Manual

IP262/Z0, Rev. AB

MSL600

 

 

 

February 2012

Programming chart continued…

 

 

 

 

 

 

 

 

 

 

 

MONITOR

READINGS

Sludge Level

D800

 

 

 

 

 

 

Target Range

D801

 

 

 

 

 

 

% Current Out

D805

 

 

 

 

 

 

Current Output

D806

 

 

 

 

Relay

 

Relay Status

D820

 

 

 

 

 

Relay Run-time

RL1 Run-Time

D821

 

 

 

 

 

 

RL2 Run-Time

D822

 

 

 

 

 

 

Cleaning Time

D824

 

 

 

 

 

 

Alarm Report

D830

 

 

 

 

 

 

Fault Report

D831

 

 

 

 

 

 

Xdr Tilt Time

D833

 

 

 

 

 

 

Noise Level

D834

 

 

 

DIAGNOSTICS

Input Status

D835

 

 

 

 

 

 

CU Temperature

D844

 

 

 

 

 

 

Xducer Temp

D845

 

 

 

 

 

 

Free Memory

D846

 

 

 

 

 

 

Date of Change

D848

 

 

 

 

 

 

Echo Sharpness

D849

 

 

 

 

 

 

Speed of Sound

D850

 

 

 

 

 

 

Max Xdr Temp

D851

 

 

 

 

 

 

Min Xdr Temp

D852

 

 

 

 

RADIO

Radio Msg Count

D853

 

 

 

 

 

 

Radio STX Count

D854

 

 

 

 

 

 

Radio Channel

D842

 

 

 

 

 

 

Radio Address

D843

 

 

DIRECT

Pxxx

 

 

-

 

 

 

 

Dxxx

-

 

 

Note: The Radio parameters are not used with this version of the MSL600.

Page 52

Image 52
Contents Installation, Operation & Maintenance Manual MSL600Contents MSL600 12.1 12.2Before Operating this Device the Manual should be Read Fully About the MSL600 About this ManualImportant MSL600 features Self-cleaningHuman Machine Interface Mounting bracketAs a system LocationCircular clarifiers Application planningRotating bridge Rectangular clarifiers Static bridgeInstallation Preliminary checksLocation Mounting bracket attachmentInstalling the bracket on the bridge Attaching the MSL600MSL600 mounting Power and other electrical connections Transducer connectionsExternal connection terminals Cable extension Programming DisplayContrast viewing angle control Keypad and Menu NavigationSecurity On-line/Off-lineQuick start parameters Tank depth Bottom referenceTransducer self-cleaning Determination of tank depthCurrent output adjust MA current output parametersRelay parameters AlarmTransducer out-of-water time Digital input Detailed operation Menu structureMain menu item Menu Item DescriptionParameter editing Direct accessScrolling Application parameters Installation parametersMain menu parameters De-sludge parameters Description P240Start On P250 Stop On P251Stop If P252 Start Time P253Interval P254 Max Retries P257Cleaning parameters MA output parametersAlarm Action P402 4 0/4-20mA P403Alarm mode relay RL1 and RL2 parameters P540 to Relay RL1 mode P410 and RL2 mode P420Table B Relay Parameter numbers Fault mode relay RL1 and RL2 parameters P560 to P570 Set point mode relay RL1 and RL2De-sludge mode relay RL1 and RL2 On mode relay RL1 and RL2Display parameters HMI Relay On and Off PointsRelay overrides Min ON, Max ON, and Min OFF HMI upper, middle, and lower display optionsClear Trend Backlight On/Off P575Clear Profile Low Mem Alarm P593 Logging parametersLog Interval P590 Fast log P591Parameter values Default Min Max 128 1024 Engineering parameters1 Alg. Select P620 Common algorithm parameters P621 to P629Parameter values Default Min Max 100 Top Blanking P623 Parameter values Default Min Max 9999 Upr S-nat Temp P625Default Min Max +85 105 185 Noise Alrm Lev P622Default Min Max +85 185 SoS constant P627 Default metric m/sLwr S-nat Temp P626 Bottom Blanking P628Parameter values Default Min Max Lost Echo Rnge P633 Municipal 1 parameters P630 to P637Significance P630 Sharp Echo Reject P631Parameter values Default Min Max Dirty Mult P636 Parameter values Default Min Max Lost Echo Time P637Parameter values Default Min Max 255 Noise SD Mult P635Parameter values Default Min Max 100 Municipal 2 parameter P640Threshld Offset P640 Threshold level = Threshld Offset P640 + Noise Level D834Load Defaults function System parametersAuto Cycle function Display testSettings parameters P730 to P737 and Base Units selection Comms parameters P710 to P716PIN parameter P740 Fixed parameters D750 to D753Readings and diagnostics parameters Readings parameters D800 to D834Diagnostics parameters D835 to D852 Max Xdr Temp D851 Speed of Sound D850Min Xdr Temp D852 Maintenance TroubleshootingTechnical reference Transmit pulse and echo processingProgramming chart Sub-menu Level Parameter Title Par No Main Menu OptionProgramming chart … Direct Specification 12.1 MSL600Model No OutputsAdditional specification notes Weight12.2 MSL603 transducer Dimensional drawings MSL600 Bridge mounted unitMSL600 and MSL603 assembly Parts required MSL603 transducer cable extensionFitting instructions MSL600 MSL600 Emerson Process Management Rosemount Measurement