9. GTI & IAM MOUNTING

The 9th step to install the ELI option, is to mount the standard GTI units, the Master GTI, and optional IAM (if supplied). Be sure that the following items have been completed before mounting:

Recorded all software version numbers

Installed GTI interface card in Master GTI

Set up telephone interface

Set DIP switches (GTI units and Master GTI)

The method used to mount GTI units in repeater cabinets is to mount all of the standard GTI units first, followed by the Master GTI. Start by mounting the first standard GTI just above the GETC for the highest numbered radio channel, the next GTI just above the GETC for the next highest numbered radio channel, and so on until all standard GTI units, and then the Master GTI are mounted.

You may use some other method. However, using the method described here assures that the supplied cables will be the correct length and the PCM/Data Bus will be as short as possible. (The PCM/Data Bus must not exceed 120 feet in length).

The 350A1154G1 GTI hardware kit, supplied with each GTI unit, provides a pair of offset brackets to brace the rear of the GTI unit to the back rails of the cabinet.

10. GTI CONNECTIONS

The 10th step to install the ELI option, is to make the connections to the GTI units (including the Master GTI). All of the connections can be made to the connectors on the

Telephone Line

The ELI TELCO Interface module, in the EDACS Interface panel at the top of each repeater cabinet, is used to consolidate the telephone connections for 6 telephone lines from up to 6 GTI units into a single 25-pair IDC telco connector for connection to a Type 66 (or equivalent) punchblock and the telephone company. A second 25-pair IDC telco connector is provided on each module to allow a 25-pair cable to connect this module in tandem with a similar module in an adjacent repeater cabinet.

CAUTION

All telephone lines must come through

protected punchblocks (or equivalent protection) before being connected to this equipment.

For each GTI unit that will be connected to a telephone line, connect a cable from the female 8-pin modular RJ-45 connector on the back of the GTI unit to one of the female 8-pin modular RJ-45 connectors (J1 through J6) on the front of the ELI TELCO interface module in the EDACS Interface Panel at the top of the cabinet (see Figure 29). Use a cable that matches the location of the GTI unit:

Use a 44" 19B803829P1 cable when the GTI is located with the top repeater.

Use a 60" 19B803829P2 cable when the GTI is located with the middle repeater.

Use a 76" 19B803829P3 cable when the GTI is located with the bottom repeater.

rear panel as shown in Figure 28.

 

Telephone

Power Supply/

 

PCM/Data

 

 

 

GTI Configurator

 

 

Line

Repeater Audio

 

Bus

 

 

 

RS-232 Port

 

 

(J1)

 

(P1)

 

(J2)

 

 

 

 

(J3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3

 

 

J4 J5

 

 

 

 

 

 

 

 

PROGRAM

 

 

 

 

 

 

 

PHONE

POWER/AUDIO

PCM/DATA BUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Master GTI Connections to Site Controller Computer

 

To Port 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To Port 31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 28 - Connections to GTI

Telephone

Company

Connections

J14

J15

 

 

J1

 

 

J2

 

 

J3

GTI

 

J4

Connections

 

J5

 

 

J6

 

 

ELI TELCO

 

Figure 29 - Connections to ELI TELCO Interface Module

24

Image 24
Contents System Manual Revision History Revision Date Reason for ChangeTable of Contents Table of Contents Figures List of Figures and TablesFigures and Tables Regulatory Compliance DOC Registration DOC Compliance NoticeDOC Avis DE Conformation Specifications SpecificationsMastr Introduction / Description OverviewDescription GTI UnitsDescription / Installation GTI Configurator SoftwareGTI Interface Board IAMInstallation MDRGTI GetcRadio Software Site Controller HardwareSite Controller Software EmptyRadio Channel Assignments Application Software PROMsPersonality PROMs GTI Software Main BoardRevision-A Main boards Revision-D or E Main boards Processor BoardInterface Board GTI Telephone Interface Revision-A Main BoardF2&F3 OUTWire E&M, Microwave Wire E&M, TypeEnd-to-End, Loop Start End-to-End, Ground Start Jumper Positions for JP1 Through JP15 Fuses External JP4 Lead Fuse F2 Reference DS1 GTI DIP Switch Settings Revision-D or E Main BoardDid GTI Interface Board Mounting GTI & IAM Mounting GTI ConnectionsTelephone Line Mastr III Power Supply/Audio Mastr II or IIe Power Supply/AudioPCM/Data Bus IAM Software Site Controller ComputerPower Supply Alarm OutputsIAM Connections Printer RS-232 PortIAM DIP Switch Settings Getc ModificationConfiguration Site Controller DatabaseInterconnect Timing Parameters Operation without System ManagerOperation with System Manager General Limits for SiteWho Can Receive Calls Who Has What Priority Who Has What Toll Call RestrictionsRecommendation GTI DatabaseRemote Data Link RTS CTSOperation CDR Received Indicator Alarm IndicatorLow-Battery Indicator Printer IndicatorBackup Interconnect CallsStatus OverviewTelephone-Originated Call Detecting the CallAnswering the Call Identifying Called ID Obtaining Working ChannelEnding the Call Radio-Originated CallObtaining a Working Channel Interconnect Digits RE-DIALED DigitsOverdialed Digits Maintenance GTI RemovalMastr II or IIe Repeaters Mastr III RepeatersELI Software Upgrades GTI DSPSoftware Version Required for Main Board Revision Number Plan a All at One TimePlan B Half at a Time Maintenance Plan C One at a Time Maintenance IAM Unit Troubleshooting No interconnect or radio-to-radioInterconnect Rotary Definition for Set the Max # Concurrent InterconAll telephone-originated interconnect Toll Call Parameters screen LBI-39076B Glossary GlossaryPresence of a DC loop current between one of the two wires Glossary / Parts List Parts ListInterconnection Diagram EdacsSchematic Diagram Installation Checklist Installation Checklist