Ericsson LBI-39076B system manual Remote Data Link, Rts Cts

Page 34

LBI-39076B

CONFIGURATION

Office PC

 

 

 

GTI Unit

COM Port

 

19D903985P72

 

J3

DB-9 (M)

DB-9 (F)

Cable

DB-9 (M)

DB-9 (F)

 

1

 

1

 

Rx Data

2

 

2

Tx Data

Tx Data

3

 

3

Rx Data

DTR

4

 

4

DTR

Signal Ground

5

 

5

Gnd

 

6

 

6

 

RTS

7

 

7

CTS

CTS

8

 

8

RTS

 

9

 

9

 

Figure 41 - Local GTI Connection for 9-Pin COM Port

Office PC

 

Adapter

 

 

 

GTI Unit

COM Port

 

 

 

19D903985P72

 

J3

DB-25 (M)

DB-25 (F)

DB-9 (M)

DB-9 (F)

Cable

DB-9 (M)

DB-9 (F)

 

 

 

1

 

1

 

Rx Data

3

 

2

 

2

Tx Data

Tx Data

2

 

3

 

3

Rx Data

DTR

20

 

4

 

4

DTR

Signal Ground

7

 

5

 

5

Gnd

 

 

 

6

 

6

 

RTS

4

 

7

 

7

CTS

CTS

5

 

8

 

8

RTS

 

 

 

9

 

9

 

Figure 42 - Local GTI Connection for 25-Pin COM Port

Remote Data Link

A remote data link using data modems will be required if the GTI database must be configured from a location over 50 feet from the GTI units. The amount of additional equipment required will depend upon which one of the following two methods is used:

1.Internal GTI Modem - Use the internal 1200-baud modem built into each GTI unit and the telephone line connected to a GTI unit. This method requires the following additional equipment:

1200-baud modem at GTI Configurator location (internal or external - cable required if external)

Available telephone line at GTI Configurator location and a cable to connect from the telephone line to the modem

2.External Modem - Use an external modem at the GTI unit location connected to the RS-232 port on the back of a GTI unit. This method requires the following additional equipment:

External modem at the GTI unit location and a cable to connect it to the RS-232 port on the back of a GTI unit

Matching modem at the GTI Configurator location (internal or external - cable required if external)

Available telephone line or other communication circuit and a cable to connect from it to the modem (at both locations)

For additional information about using a remote data link, see the Data Link To GTI Units section in the GTI Configurator software user’s guide.

34

Image 34
Contents System Manual Revision History Revision Date Reason for ChangeTable of Contents Table of Contents Figures List of Figures and TablesFigures and Tables Regulatory Compliance DOC Compliance Notice DOC RegistrationDOC Avis DE Conformation Specifications SpecificationsMastr Introduction / Description OverviewDescription GTI UnitsGTI Interface Board Description / InstallationGTI Configurator Software IAMGTI InstallationMDR GetcSite Controller Software Radio SoftwareSite Controller Hardware EmptyApplication Software PROMs Radio Channel AssignmentsPersonality PROMs Main Board GTI SoftwareRevision-A Main boards Processor Board Revision-D or E Main boardsInterface Board F2&F3 GTI Telephone InterfaceRevision-A Main Board OUTWire E&M, Type Wire E&M, MicrowaveEnd-to-End, Loop Start End-to-End, Ground Start Jumper Positions for JP1 Through JP15 Fuses External JP4 Lead Fuse F2 Reference DS1 Revision-D or E Main Board GTI DIP Switch SettingsDid GTI Interface Board Mounting GTI Connections GTI & IAM MountingTelephone Line Mastr II or IIe Power Supply/Audio Mastr III Power Supply/AudioPCM/Data Bus IAM Software Site Controller ComputerIAM Connections Power SupplyAlarm Outputs Printer RS-232 PortIAM DIP Switch Settings Getc ModificationInterconnect Timing Parameters ConfigurationSite Controller Database Operation without System ManagerOperation with System Manager General Limits for SiteWho Can Receive Calls Who Has What Priority Who Has What Toll Call RestrictionsRecommendation GTI DatabaseRemote Data Link RTS CTSOperation Low-Battery Indicator CDR Received IndicatorAlarm Indicator Printer IndicatorStatus BackupInterconnect Calls OverviewDetecting the Call Telephone-Originated CallAnswering the Call Identifying Called ID Obtaining Working ChannelRadio-Originated Call Ending the CallObtaining a Working Channel Interconnect Digits RE-DIALED DigitsOverdialed Digits Mastr II or IIe Repeaters MaintenanceGTI Removal Mastr III RepeatersELI Software Upgrades GTI DSPSoftware Version Required for Main Board Revision Number Plan a All at One TimePlan B Half at a Time Maintenance Plan C One at a Time Maintenance IAM Unit Troubleshooting No interconnect or radio-to-radioSet the Max # Concurrent Intercon Interconnect Rotary Definition forAll telephone-originated interconnect Toll Call Parameters screen LBI-39076B Glossary GlossaryPresence of a DC loop current between one of the two wires Glossary / Parts List Parts ListInterconnection Diagram EdacsSchematic Diagram Installation Checklist Installation Checklist