CONFIGURATION

LBI-39076B

CONFIGURATION

OVERVIEW

The user configurable parameters for the ELI option reside in two locations: the Site Controller computer’s database and the GTI units’ database. The configuration of these two databases is covered in this section.

Rotary Defaults - Defines which line numbers are to be considered when hunting for an available line. This field should only list existing line numbers. Listing non-existent line numbers may delay the line assignments for radio- initiated interconnect calls. In the previous example, line numbers one through four would not exist and should not be entered in the Rotary Defaults field.

Interconnect Timing Parameters

SITE CONTROLLER DATABASE

The overall operation of the ELI option is controlled by the software in the Site Controller computer and the active configuration of the Site Controller computer’s database. This active configuration must reflect the installed telephone interconnect hardware and the desired operational characteristics. The Site Controller must use Release 5 (group 5, version 6.xx) or higher software to support ELI. However, it is highly recommended that the Site Controller use Release 7 (group 7, version 7.xx) or higher software to ensure the proper and efficient operation of the ELI system.

Operation without System Manager

If the Site Controller computer is not connected to a System Manager, the active configuration of its database will always be the default configuration contained in its Personality PROMs. Therefore, this default configuration must reflect the installed telephone interconnect hardware and the desired operational characteristics.

If the telephone interconnect hardware or the desired operational characteristics change, it will be necessary to order a new set of Site Controller computer Personality PROMs. To assure that the new PROMs will accurately reflect these changes, it is important to pay particular attention to the following two data fields used by the Site Controller personality programmer to make the new Personality PROMs. (This is because telephone lines are typically numbered differently in the ELI option than they were in the previous telephone interconnect option.)

Max Line - Defines the highest telephone line number used. For the ELI option, the standard procedure is to assign telephone line numbers to the highest equipped radio channel numbers, with the telephone line numbers corresponding to the channel numbers. Therefore, a seven- channel ELI site with three telephone lines would have telephone line numbers five through seven, and you would enter 7 in the Max Line field.

NOTE

If upgrading to Release 7 Site Controller Application Software, check these interconnect timing settings.

If the Site Controller has Release 7 or later site controller software, the interconnect timing parameters in the Site Controller personality may need to be altered. These timing parameters are designed to guide system response time to certain interconnect sequences, such as dial tone detection and DTMF digit detection. The Site Controller pre-Release 7 software added significant time to these timing parameters. As an example, the dial tone detection duration defaults to one second. Prior to this release, the site controller would in fact wait 1.6 seconds for dial tone. Another example is the DTMF digit detect duration, which defaults to 20 seconds for ELI. Prior to this release, the 20 second time-out was in reality 32 seconds. These examples indicate that rotary hunts would take longer and interconnect resource recovery would be further delayed beyond what a customer called out in the Site Controller personality. At best this causes confusion, making it more difficult to tailor an EDACS system per customer needs.

With Release 7 and later software, the interconnect timings are accurate. The accurate timings provide the benefit of reliable customization of system operation per customer needs (e.g., dial tone detection) and increased interconnect call throughput by more quickly recovering interconnect resources for use by future calls. This carries certain implications, most notable of which is dial tone detection. If a customer application reports dial tone within 1 to 1.5 seconds, for example, previous software releases would reliably process dial tone detection with a personality value of 1 second. Release 7 (or later), however, would not, resulting in either a rotary hunt or, worse, misdialing on one or more lines (see open DSR #4324). To remedy this problem, the site controller personality should be updated concurrent with the Release 7 (or later) upgrade to provide the same relative time margin for dial tone detection, namely increase the duration from 1 second to 1.6 seconds.

29

Image 29
Contents System Manual Revision Date Reason for Change Revision HistoryTable of Contents Table of Contents List of Figures and Tables FiguresFigures and Tables Regulatory Compliance DOC Avis DE Conformation DOC RegistrationDOC Compliance Notice Mastr SpecificationsSpecifications Overview Introduction / DescriptionGTI Units DescriptionGTI Configurator Software Description / InstallationGTI Interface Board IAMMDR InstallationGTI GetcSite Controller Hardware Radio SoftwareSite Controller Software EmptyPersonality PROMs Radio Channel AssignmentsApplication Software PROMs Revision-A Main boards GTI SoftwareMain Board Interface Board Revision-D or E Main boardsProcessor Board Revision-A Main Board GTI Telephone InterfaceF2&F3 OUTEnd-to-End, Loop Start End-to-End, Ground Start Wire E&M, MicrowaveWire E&M, Type Jumper Positions for JP1 Through JP15 Fuses External JP4 Lead Fuse F2 Reference DS1 Did GTI DIP Switch SettingsRevision-D or E Main Board GTI Interface Board Mounting Telephone Line GTI & IAM MountingGTI Connections PCM/Data Bus Mastr III Power Supply/AudioMastr II or IIe Power Supply/Audio Site Controller Computer IAM SoftwareAlarm Outputs Power SupplyIAM Connections Printer RS-232 PortGetc Modification IAM DIP Switch SettingsSite Controller Database ConfigurationInterconnect Timing Parameters Operation without System ManagerGeneral Limits for Site Operation with System ManagerWho Can Receive Calls Who Has What Toll Call Restrictions Who Has What PriorityGTI Database RecommendationRTS CTS Remote Data LinkOperation Alarm Indicator CDR Received IndicatorLow-Battery Indicator Printer IndicatorInterconnect Calls BackupStatus OverviewAnswering the Call Telephone-Originated CallDetecting the Call Obtaining Working Channel Identifying Called IDObtaining a Working Channel Ending the CallRadio-Originated Call RE-DIALED Digits Interconnect DigitsOverdialed Digits GTI Removal MaintenanceMastr II or IIe Repeaters Mastr III RepeatersGTI DSP ELI Software UpgradesPlan a All at One Time Software Version Required for Main Board Revision NumberPlan B Half at a Time Maintenance Plan C One at a Time Maintenance IAM Unit No interconnect or radio-to-radio TroubleshootingAll telephone-originated interconnect Interconnect Rotary Definition forSet the Max # Concurrent Intercon Toll Call Parameters screen LBI-39076B Glossary GlossaryPresence of a DC loop current between one of the two wires Parts List Glossary / Parts ListEdacs Interconnection DiagramSchematic Diagram Installation Checklist Installation Checklist