CONFIGURATION

LBI-39076B

Who Has What Dedicated Line

Dedicated Line - This 3-digit field defines (for each logical unit ID) the line number to be dedicated to outgoing interconnect calls. Default is line 1. Enter a line number, or 0 for denial. It is recommended that you enter 0 for denial, and use unique rotary hunt sequences to define dedicated lines.

Logical Unit Definition (menu selection 11) Radio Parameters (panel 2)

Interconnect

Dedicated To Unit - This column of parameters defines (for the site) the logical unit ID to which each line is dedicated. Default is no logical unit ID (0) for all lines. Enter a logical unit ID, or leave 0 for no logical unit ID. It is recommended that you leave 0 for no logical unit ID, and use unique rotary hunt sequences to define dedicated lines.

Line Definition (menu selection 14) Line Parameters (pages 1 & 2)

RECOMMENDATION

It is recommended that all dedicated line assignments be set up by using the Rotary

Number and Interconnect Rotary Definition

parameters, not the Dedicated Line parameter. Set the Dedicated Line parameter to none (0), and assign a unique Rotary Number and a single unique line number in the corresponding

Interconnect Rotary Definition for each logical

unit ID requiring a dedicated line.

Existing telephone interconnect systems that currently have dedicated lines defined by using non-zero values for the Dedicated Line and Dedicated To Unit parameters, can continue to use this method with the ELI system. However, because the lines are typically numbered differently for the ELI system, some reconfiguring of the line numbers will probably be necessary. If you find this to be the case, you may want to change to the recommended method at this time, as described above.

GTI DATABASE

Some user-configurable parameters for the ELI system reside in the active configuration of the GTI database, in each GTI unit. The GTI database is configured with the

GTI Configurator software, using an office PC connected through a data link to one GTI unit. The re-configured GTI database will be cloned to each other GTI unit that is connected to this one GTI unit.

Local Data Link

Using a local data link between an office PC and one GTI unit, requires less equipment and is less complicated to set up than a remote data link. A local data link should not exceed 50 feet in length and requires the following four items:

1.PC-Based Terminal (Not Supplied) - The customer must supply a PC-based terminal with the following features:

IBM-compatible 386 or better

MS-DOS version 3.2 minimum operating system

10 MB available hard drive

640 KB minimum RAM (recommend 2 MB)

1.2 MB 5.25-inch or 1.44 MB 3.5-inch floppy drive

Monochrome or color monitor

Available male 9-pin RS-232 port (If a male 9-pin serial port is not available, an adapter will be required.)

2.RS-232 Data Cable (Supplied) - A 10-foot 19D903985P72 cable is supplied with male and female 9-pin connectors.

3.GTI Configurator Software (Supplied) - The GTI Configurator software is supplied in both 3.5 and 5.25- inch floppy formats.

4.GTI Configurator User’s Guide (Supplied)

Figure 41 shows how an office PC with a 9-pin COM port is connected to a GTI unit. Figure 42 shows how an office PC with a 25-pin COM port is connected to a GTI unit.

33

Image 33
Contents System Manual Revision Date Reason for Change Revision HistoryTable of Contents Table of Contents List of Figures and Tables FiguresFigures and Tables Regulatory Compliance DOC Registration DOC Compliance NoticeDOC Avis DE Conformation Specifications SpecificationsMastr Overview Introduction / DescriptionGTI Units DescriptionGTI Configurator Software Description / InstallationGTI Interface Board IAMMDR InstallationGTI GetcSite Controller Hardware Radio SoftwareSite Controller Software EmptyRadio Channel Assignments Application Software PROMsPersonality PROMs GTI Software Main BoardRevision-A Main boards Revision-D or E Main boards Processor BoardInterface Board Revision-A Main Board GTI Telephone InterfaceF2&F3 OUTWire E&M, Microwave Wire E&M, TypeEnd-to-End, Loop Start End-to-End, Ground Start Jumper Positions for JP1 Through JP15 Fuses External JP4 Lead Fuse F2 Reference DS1 GTI DIP Switch Settings Revision-D or E Main BoardDid GTI Interface Board Mounting GTI & IAM Mounting GTI ConnectionsTelephone Line Mastr III Power Supply/Audio Mastr II or IIe Power Supply/AudioPCM/Data Bus Site Controller Computer IAM SoftwareAlarm Outputs Power SupplyIAM Connections Printer RS-232 PortGetc Modification IAM DIP Switch SettingsSite Controller Database ConfigurationInterconnect Timing Parameters Operation without System ManagerGeneral Limits for Site Operation with System ManagerWho Can Receive Calls Who Has What Toll Call Restrictions Who Has What PriorityGTI Database RecommendationRTS CTS Remote Data LinkOperation Alarm Indicator CDR Received IndicatorLow-Battery Indicator Printer IndicatorInterconnect Calls BackupStatus OverviewTelephone-Originated Call Detecting the CallAnswering the Call Obtaining Working Channel Identifying Called IDEnding the Call Radio-Originated CallObtaining a Working Channel RE-DIALED Digits Interconnect DigitsOverdialed Digits GTI Removal MaintenanceMastr II or IIe Repeaters Mastr III RepeatersGTI DSP ELI Software UpgradesPlan a All at One Time Software Version Required for Main Board Revision NumberPlan B Half at a Time Maintenance Plan C One at a Time Maintenance IAM Unit No interconnect or radio-to-radio TroubleshootingInterconnect Rotary Definition for Set the Max # Concurrent InterconAll telephone-originated interconnect Toll Call Parameters screen LBI-39076B Glossary GlossaryPresence of a DC loop current between one of the two wires Parts List Glossary / Parts ListEdacs Interconnection DiagramSchematic Diagram Installation Checklist Installation Checklist