Ericsson LBI-39076B system manual Specifications, Mastr

Page 9

 

SPECIFICATIONS

LBI-39076B

 

SPECIFICATIONS

 

Dimensions:

 

 

Master GTI

1.75" H x 19.00" W x 12.00" D

 

GTI

1.75" H x 19.00" W x 12.00" D

 

IAM

1.75" H x 19.00" W x 7.00" D

 

Environmental:

 

 

Temperature Range

0° to 70° C (32° to 158° F)

 

Relative Humidity

95% (max.)

 

Power:

 

 

Input Voltage

12 Volts dc (nominal)

 

Input Power

 

 

Master GTI

12 Watts (max.) / 8 Watts (avg.)

 

GTI

12 Watts (max.) / 8 Watts (avg.)

 

IAM

6 Watts (avg.)

 

EDACS Repeater Types:

 

 

...............................................................

MASTR II

 

...............................................................

MASTR IIe

 

...............................................................

MASTR III

 

PSTN Line Types:

 

 

...............................................................

End-to-End, Loop Start

 

...............................................................

End-to-End, Ground Start

 

...............................................................

2/4-Wire E&M, Microwave

 

...............................................................

2/4-Wire E&M, Type I

 

...............................................................

Direct Inward Dial (DID)

 

PSTN Dialing Types:

 

 

Encoded by GTI:

 

 

...............................................................

Rotary Dial (Dial Pulse)

 

...............................................................

Push-Button Dial (DTMF)

 

...............................................................

Multifrequency R1/R2

 

Decoded by GTI (Overdialed):

 

 

...............................................................

Rotary Dial (Dial Click)

 

...............................................................

Push-Button Dial (DTMF)

 

...............................................................

Multifrequency R1/R2

 

9

Image 9
Contents System Manual Revision Date Reason for Change Revision HistoryTable of Contents Table of Contents List of Figures and Tables FiguresFigures and Tables Regulatory Compliance DOC Registration DOC Compliance NoticeDOC Avis DE Conformation Specifications SpecificationsMastr Overview Introduction / DescriptionGTI Units DescriptionGTI Configurator Software Description / InstallationGTI Interface Board IAMMDR InstallationGTI GetcSite Controller Hardware Radio SoftwareSite Controller Software EmptyRadio Channel Assignments Application Software PROMsPersonality PROMs GTI Software Main BoardRevision-A Main boards Revision-D or E Main boards Processor BoardInterface Board Revision-A Main Board GTI Telephone InterfaceF2&F3 OUTWire E&M, Microwave Wire E&M, TypeEnd-to-End, Loop Start End-to-End, Ground Start Jumper Positions for JP1 Through JP15 Fuses External JP4 Lead Fuse F2 Reference DS1 GTI DIP Switch Settings Revision-D or E Main BoardDid GTI Interface Board Mounting GTI & IAM Mounting GTI ConnectionsTelephone Line Mastr III Power Supply/Audio Mastr II or IIe Power Supply/AudioPCM/Data Bus Site Controller Computer IAM SoftwareAlarm Outputs Power SupplyIAM Connections Printer RS-232 PortGetc Modification IAM DIP Switch SettingsSite Controller Database ConfigurationInterconnect Timing Parameters Operation without System ManagerGeneral Limits for Site Operation with System ManagerWho Can Receive Calls Who Has What Toll Call Restrictions Who Has What PriorityGTI Database RecommendationRTS CTS Remote Data LinkOperation Alarm Indicator CDR Received IndicatorLow-Battery Indicator Printer IndicatorInterconnect Calls BackupStatus OverviewTelephone-Originated Call Detecting the CallAnswering the Call Obtaining Working Channel Identifying Called IDEnding the Call Radio-Originated CallObtaining a Working Channel RE-DIALED Digits Interconnect DigitsOverdialed Digits GTI Removal MaintenanceMastr II or IIe Repeaters Mastr III RepeatersGTI DSP ELI Software UpgradesPlan a All at One Time Software Version Required for Main Board Revision NumberPlan B Half at a Time Maintenance Plan C One at a Time Maintenance IAM Unit No interconnect or radio-to-radio TroubleshootingInterconnect Rotary Definition for Set the Max # Concurrent InterconAll telephone-originated interconnect Toll Call Parameters screen LBI-39076B Glossary GlossaryPresence of a DC loop current between one of the two wires Parts List Glossary / Parts ListEdacs Interconnection DiagramSchematic Diagram Installation Checklist Installation Checklist