Ericsson LBI-39076B system manual Who Has What Priority, Who Has What Toll Call Restrictions

Page 32

LBI-39076B

CONFIGURATION

Who Has What Priority

Interconnect - This 1-digit field defines (for each logical unit ID) which of eight queuing priority levels (from 0 to 7) is to be applied to this specific logical unit ID for interconnect calls. Default is the lowest priority

(0).

Logical Unit Definition (menu selection 11) Radio Parameters (panel 2)

Call Priority

Interconnect - This 1-digit field defines (for each group ID) which of eight queuing priority levels (from 0 to 7) is to be applied to this specific group ID for interconnect calls. Default is the lowest priority (0).

Group Definition (menu selection 12) Group Parameters (panel 2)

Call Priority

Who Has What Toll Call Restrictions

Digit Patterns - This column of parameters defines (for the site) up to 16 digit patterns for the first four digits of an outgoing interconnect call. An X used as a digit in a pattern allows that digit to be any number from 0 to 9. A string of 4 periods is used to represent an unused pattern. Default is unused (....) for all patterns.

Toll Call Restrictions (menu selection 15) Toll Call Parameters (panel 1)

Restriction Levels - These 16 columns of parameters define (for the site) which of 16 digit patterns will be permitted for each of the 16 toll call restriction levels. Default is no (N) for each of the 16 digit patterns for each of the 16 toll call restriction levels. Enter Y for yes, or leave N for no.

Toll Call Restrictions (menu selection 15) Toll Call Parameters (panel 1)

Toll Call Restrictions - This 2-digit field defines (for each logical unit ID) which of 16 toll call restriction levels (from 0 to 15) is to be applied to this specific logical unit ID for interconnect calls. Default is restriction level zero (0).

Logical Unit Definition (menu selection 11) Radio Parameters (panel 2)

Interconnect

Who Has What Rotary Hunt Sequence

Interconnect Rotary Definition - These 15 rows of parameters define a 16-line rotary hunt sequence for each of the 15 non-zero Rotary Numbers. Default is zero (0) for each line. Starting from the left, assign the valid line numbers in any order. Leave the unassigned line numbers set to zero (0). Note that a line number gets its number from the radio channel number that shares the same GTI Unit. Also note that GTI Units are placed on the highest available channel numbers first. Assigning non-existent line numbers will delay the rotary hunt sequence.

Rotary Definition (menu selection 13) Interconnect Rotary Definition (panels 1 & 2)

Rotary Number - This 2-digit field defines (for each logical unit ID) which rotary number (from 0 to 15) is to be applied to this specific logical unit ID. Default is none (0). This number (other than 0 for none) is meaningless by itself. The actual rotary hunt sequence telling which line numbers are searched and in what order (while searching for an available line) is defined by the Interconnect Rotary Definition.

Logical Unit Definition (menu selection 11) Radio Parameters (panel 2)

Interconnect

NOTE

For someone to be able to make a radio-initiated interconnect call, a Dedicated Line or Rotary Number must be defined for that logical unit ID. The default values for these parameters define line 1 as the Dedicated Line and no Rotary Number to each logical unit ID. Therefore each logical unit ID has access to line 1.

In an ELI system, line number 1 will typically not exist. In that case the default values for Dedicated Line and Rotary Number will block all outgoing interconnect calls from each logical unit ID.

Therefore, you must assign a Rotary Number to each logical unit ID and one or more valid line numbers to each of these assigned rotary numbers in the Interconnect Rotary Definition, or assign a valid line number as the Dedicated Line for each logical unit ID. We recommend using the Rotary Number and Interconnect Rotary Definition.

32

Image 32
Contents System Manual Revision History Revision Date Reason for ChangeTable of Contents Table of Contents Figures List of Figures and TablesFigures and Tables Regulatory Compliance DOC Avis DE Conformation DOC RegistrationDOC Compliance Notice Mastr SpecificationsSpecifications Introduction / Description OverviewDescription GTI UnitsDescription / Installation GTI Configurator SoftwareGTI Interface Board IAMInstallation MDRGTI GetcRadio Software Site Controller HardwareSite Controller Software EmptyPersonality PROMs Radio Channel AssignmentsApplication Software PROMs Revision-A Main boards GTI SoftwareMain Board Interface Board Revision-D or E Main boardsProcessor Board GTI Telephone Interface Revision-A Main BoardF2&F3 OUTEnd-to-End, Loop Start End-to-End, Ground Start Wire E&M, MicrowaveWire E&M, Type Jumper Positions for JP1 Through JP15 Fuses External JP4 Lead Fuse F2 Reference DS1 Did GTI DIP Switch SettingsRevision-D or E Main Board GTI Interface Board Mounting Telephone Line GTI & IAM MountingGTI Connections PCM/Data Bus Mastr III Power Supply/AudioMastr II or IIe Power Supply/Audio IAM Software Site Controller ComputerPower Supply Alarm OutputsIAM Connections Printer RS-232 PortIAM DIP Switch Settings Getc ModificationConfiguration Site Controller DatabaseInterconnect Timing Parameters Operation without System ManagerOperation with System Manager General Limits for SiteWho Can Receive Calls Who Has What Priority Who Has What Toll Call RestrictionsRecommendation GTI DatabaseRemote Data Link RTS CTSOperation CDR Received Indicator Alarm IndicatorLow-Battery Indicator Printer IndicatorBackup Interconnect CallsStatus OverviewAnswering the Call Telephone-Originated CallDetecting the Call Identifying Called ID Obtaining Working ChannelObtaining a Working Channel Ending the CallRadio-Originated Call Interconnect Digits RE-DIALED DigitsOverdialed Digits Maintenance GTI RemovalMastr II or IIe Repeaters Mastr III RepeatersELI Software Upgrades GTI DSPSoftware Version Required for Main Board Revision Number Plan a All at One TimePlan B Half at a Time Maintenance Plan C One at a Time Maintenance IAM Unit Troubleshooting No interconnect or radio-to-radioAll telephone-originated interconnect Interconnect Rotary Definition forSet the Max # Concurrent Intercon Toll Call Parameters screen LBI-39076B Glossary GlossaryPresence of a DC loop current between one of the two wires Glossary / Parts List Parts ListInterconnection Diagram EdacsSchematic Diagram Installation Checklist Installation Checklist