RAD Data comm MBE10-1D, MBE10-8D operation manual MBE Family LAN RANger Series

Page 3

MBE Family (LAN RANger Series)

Ethernet Remote Access Routers (MBE10-1, MBE10-8,

MBE10-1D, MBE10-8D)

Version 7

Installation and Operation Manual

Notice

This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications.

Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the MBE Family (LAN RANger Series) and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD.

MBE Family (LAN RANger Series) is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark.

You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the MBE Family (LAN RANger Series). You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the MBE Family (LAN RANger Series), based on or derived in any way from the MBE Family (LAN RANger Series). Your undertaking in this paragraph shall survive the termination of this Agreement.

This Agreement is effective upon your opening of the MBE Family (LAN RANger Series) package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the MBE Family (LAN RANger Series) and all copies and portions thereof.

For further information contact RAD at the address below or contact your local distributor.

 

International Headquarters

U.S. Headquarters

 

 

RAD Data Communications Ltd.

RAD Data Communications Inc.

 

 

24 Raoul Wallenberg St.

900 Corporate Drive

 

 

Tel Aviv 69719 Israel

Mahwah, NJ 07430 USA

 

 

Tel: 972-3-6458181

Tel: (201) 529-1100, Toll free: 1-800-444-7234

 

 

Fax: 972-3-6498250

Fax: (201) 529-5777

 

 

E-mail:rad@rad.co.il

E-mail:market@radusa.com

 

 

 

 

 

© 1994-2003 RAD Data Communications Ltd.

Publication No. 572-200-02/03

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Image 3
Contents MBE Family LAN RANger Series Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 MBE Family LAN RANger Series Limited Warranty Please observe the following precautions General Safety InstructionsGeneral Safety Practices Connection of AC MainsConnection of DC Mains Connection of Data and Telecommunications Cables Electromagnetic Compatibility EMC Canadian Emission Requirements Declaration of Conformity Conventions Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 Contents List of Figures MBE10-8D throughout this manual OverviewGeneral VersionsManagement FeaturesApplications Routing and Bridging SupportWAN Economy Quick SetupTransparent Remote-to-Remote Forwarding SecurityRear Panel Physical DescriptionDual Image Flash Memory Front PanelRouting Mode Bridge ModeFunctional Description MBE10-1D Operation Bridge Mode CompatibilityPrinciples of Operation MBE10-1 OperationFunctional Block Diagram MBE10-8 OperationMBE10-8D Operation LAN Processor LAN InterfaceManagement LAN Interface Standard Technical SpecificationsInterface Connectors Type Connectors Link InterfaceYellow On when a packet is being received from the LAN Green On when the unit is powered-upGreen On when packets can be transferred Yellow On when a packet is being transmitted to the LAN50 C/32 -122 F Temperature Humidity To 90%, non-condensingTechnician who is aware of the hazards involved Maintenance of this productIntroduction Site Requirements and PrerequisitesPackage Contents Installation and SetupEquipment Needed Configuring MBE To configure the MBE unitBridge Application MBE PCB Layout Main MBE Switches and JumpersIL-4W 24D, V.35D Connecting the InterfacesTo connect to the LAN Connecting the LineConnecting the LAN To connect the lineAC Power Connecting the PowerInstallation Installation and Setup Front Panel Controls and Indicators Front Panel Controls and IndicatorsIt is suggested to use 9.6 kbps Initial SetupTo begin configuring MBE Operating InstructionsPower-on Power-offOperating MBE Operation Operating Instructions To perform the ping test Diagnostic TestAlarms and Troubleshooting Ping TerminalTo view the Debug Messages log Troubleshooting GuideDebugging Messages Debug Messages FiltersResetting MBE to Factory Settings To reset the MBE to the factory settingsTo filter the Debug Messages log Troubleshooting and Diagnostics Appendix a Pin Assignment Table A-1. Interface Signal List Female ConnectorsFemale DB-37 RS-530 21 / 15-pin Appendix a Pin Assignment 35/ DB-25 Figure A-4. Four-Wire 4W Connection Table A-3. Isdn S Interface Cable Pin Assignments Index Xmodem Excellent Good Fair Poor Very Poor Customer Response FormOrder from Cutter Networks Ph727-398-5252/Fax727-397-9610 Error Report Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters