MBE Family Installation and Operation Manual | Chapter 1 Introduction |
|
|
Bridge Mode Filtering Block (MBE10-8 and MBE10-8D only)
In addition to
If a frame is addressed to one of the remote workstations, the local MBE forwards this frame to the link. The remote MBE compares the destination address of every frame transmitted on the remote LAN with the remote workstation address table.
All frames in the remote LAN, containing destination addresses not included in the remote workstation address table, will be forwarded to the link by the remote MBE.
If the frame destination address is of the broadcast or multicast type, the filtering block compares the source address of the frame to the remote workstation address table. This source address check results in a copy/not copy command for the LAN processor.
Link Interface
The link interface provides the physical connection to either
Main Processor and Communication Processor
The main processor controls the LAN and communication processors. It performs buffer management and transfers the frames received from the LAN for transmission to the link and vice versa.
The communication processor provides an HDLC link for transmission and reception of frames to the main processor. Error checks and retransmissions ensure an
Power Supply
The MBE power supply provides required operating voltages. The power supply input ranges between 100 VAC to 240 VAC.
Asynchronous Control Port
The
Management
Quick setup and configuration is performed via a terminal emulator attached to the control port, or via TELNET access to the device over the LAN or WAN.
An SNMP agent provides
Software downloading is available through the control port, using XMODEM, and through the LAN or WAN using TFTP. Parameter file downloading and uploading is available through the LAN or WAN using TFTP.
Functional Description |