Error Messages
The error messages are displayed in the STATUS MESSAGE window on the projector and the Error display window of the SRX Controller. If there are two or more messages, a displayed message changes each 5 seconds. Use the list below to check the meaning of the error, and consult with qualified Sony personnel. Be sure to inform them of the displayed messages and their numbers.
No. | Error messages | Meaning |
1 | Trouble with power of INPUT A board | |
|
|
|
2 | Trouble with power of INPUT B board | |
|
|
|
3 | Trouble with power of INPUT C board | |
|
|
|
4 | Trouble with power of INPUT D board | |
|
|
|
5 | Trouble with power of | |
|
|
|
6 | Trouble with power of | |
|
|
|
7 | Trouble with power of | |
|
|
|
8 | Trouble with power of | |
|
|
|
9 | 24V POWER SUPPLY ALERT | The projector has failed to supply 24V power. |
|
|
|
10 | 16V POWER SUPPLY ALERT | The projector has failed to supply 16V power. |
|
|
|
11 | The | |
|
|
|
12 | SXRD PANEL TEMPERATURE | The temperature of the panels is too high. |
| ALERT |
|
|
|
|
13 | LAMP_A FAN ALERT | Trouble with the for Lamp A, or the harness is disconnected or down. |
|
|
|
14 | LAMP_B FAN ALERT | Trouble with the for Lamp B, or the harness is disconnected or down. |
|
|
|
15 | LAMP_A POWER SUPPLY UNIT | Trouble with the ballast fan for Lamp A power, or the harness is disconnected or down. |
| FAN ALERT |
|
|
|
|
16 | LAMP_B POWER SUPPLY UNIT | Trouble with the ballast fan for Lamp B power, or the harness is disconnected or down. |
| FAN ALERT |
|
|
|
|
17 | Trouble with the fan for | |
|
|
|
18 | OPTICAL UNIT TEMPERATURE | The temperature of the optical unit is too high, or the harness is disconnected or down. |
| ALERT |
|
|
|
|
19 | LAMP_A TEMPTEMPERATURE | The temperature of Lamp A is too high, or the harness is disconnected or down. |
| ALERT |
|
|
|
|
20 | LAMP_B TEMPTEMPERATURE | The temperature of Lamp B is too high, or the harness is disconnected or down. |
| ALERT |
|
|
|
|
21 | LAMP_A HOUSE DETACHED | The projection lamp house of Lamp A is not installed correctly, or the harness is |
|
| disconnected or down. |
|
|
|
22 | LAMP_B HOUSE DETACHED | The projection lamp house of Lamp B is not installed correctly, or the harness is |
|
| disconnected or down. |
|
|
|
23 | REAR COVER DETACHED | The rear cover is open, or the harness is disconnected or down. |
|
|
|
24 | LAMP_A POWER SUPPLYUNIT | Trouble with the power (ballast) of Lamp A |
| ALERT |
|
|
|
|
25 | LAMP_B POWER SUPPLY UNIT | Trouble with the power (ballast) of Lamp B |
| ALERT |
|
|
|
|
26 | LAMP_A IGNITION FAILURE | Lamp A does not turn on. |
|
|
|
27 | LAMP_B IGNITION FAILURE | Lamp B does not turn on. |
|
|
|
28 | CPU ALERT | Trouble with the main CPU (IC301) on the |
|
|
|
29 | MUTING OFF FAILURE | Trouble with opening/shutting of the shutter, or the harness is disconnected or down. |
| DOUSER OPEN FAILURE |
|
|
|
|
30 | INPUT BOARD FAN ALERT | Trouble with the HIF fan next to the INPUT A/B/C/D boards, or the harness is |
|
| disconnected or down. |
|
|
|
Chapter 5 Others
Error Messages