Sony SRX- R110, SRX-R105 operating instructions Installation Window, Frame Adjust

Page 28

Chapter 4 Adjustments and Settings Using the SRX Controller

Frame Adjust

Adjusts the horizontal size and the position of the picture.

Clicking increases the setting value, and decreases it.

Clicking the RESET button resets all the settings of “Frame Adjust” to the factory-preset values.

Dot Phase: Adjusts the phase of the SXRD panels and the input signal. Adjusts the value to obtain the clearest picture.

H Size: Adjusts the horizontal size of the picture according to the input signal. As the setting value increases, the horizontal size of the picture becomes larger.

H Shift: Adjusts the horizontal position of the picture. As the setting value increases, the picture moves to the right. As the value decreases, the picture moves to the left.

V Shift: Adjusts the vertical position of the picture. As the setting value increases, the picture moves up. As the value decreases, the picture moves down.

Notes

Adjustment of “Dot Phase” and “H Size” is available for computer signal input only.

If the position of the picture is not adjusted correctly, noise may appear in the blank portion of the screen. This is not a malfunction of the projector. Adjust the picture position correctly with “Frame Adjust.”

INSTALLATION Window

The INSTALLATION window is used to adjust the projected picture, change the lamp output, etc.

LENS CONTROL

Adjusts the projected picture on the screen.

Zoom +/–:Adjusts the size of the picture. Clicking

enlarges the picture size, and reduces the picture size.

Focus +/–:Adjusts the picture focus. Clicking focuses

on a forward picture. Clicking focuses on a picture further back.

Shift +/–:Adjusts the vertical position of the picture.

Clicking moves the picture upward. Clicking moves it downward.

PROGRESSIVE DISPLAY MODE

Normally, click the Off radio button.

Click the On radio button when four HD images with 2048 (1920) × 1080 pixels are input from four HD-SDI input boards and are combined into a 4096 (3840) × 2160-pixel image on the screen in “quad-screen” mode.

LAMP POWER

Adjusts the lamp power output. You can reduce the lamp power to 93%, 86%, 79%, 72%, 65%, 58% or 51%. The brightness of the projected image will be darker, but power consumption can be reduced and this increases the lamp life. Clicking the 100% radio button allows you to obtain the brightest projection image.

Note

Switching the lamp output frequently may reduce the lamp life. Use of the defined lamp output is recommended.

GB 28

INSTALLATION Window

Image 28
Contents SR Projector For the customers in the USA For the customers in EuropePour les utilisateurs en Europe Für Kunden in EuropaTable of Contents Projecting OthersPrecautions On safetyOn installation On illuminationUsing the CD-ROM Manual On cleaningCD-ROM System Requirements Reading the CD-ROM ManualHigh Brightness, High Picture Quality FeaturesFlexible and Reliable System Versatile Setup Various signal inputLocation and Function of Controls Optional lensLeft Side/Rear Control Function Menu WindowPassword menu Screen Control windowFile menu Back menuRemote Commander 11 GBScreen SEL buttons To install batteriesLens Cont buttons Unsuitable Installation Precautions on Installation13 GB Using the Carrying Handles Using the AdjustersUnsuitable Conditions Blocking the ventilation holesInstalling the Projector Installing the SRX ControllerSystem Requirements 15 GBPreparations Connecting the Computer via the RS-232C Connecting the Computer via the Ethernet17 GB Changing the Connection Mode Starting the SRX ControllerStarting the SRX Controller About the Browser ScreenConnecting the Projector Connecting with HD-SDI EquipmentWhen you connect the projector, make sure to 19 GBConnecting with a Computer Projecting the Picture Using the Remote Commander21 GB When you select dual-screen mode or quad-screen mode in step Using the Computer for Controlling the Projector 23 GBTo cut off the picture To turn off the powerTo cut off the whole screen To reset the settings that have been adjusted To register the settings that have been adjusted 25 GB To go back to the Browser ScreenSignal Info Information About the items that cannot be adjustedPicture Control Window Input SourceSignal Adjust COLOR/FRAME WindowColor 27 GBInstallation Window Frame AdjustManual Lamp Select Mode Auto Lamp Select Mode29 GB Signal Adjust Input Signals And Adjustable/Setting ItemsFrame Adjust Lamp Life 31 GBTroubleshooting PowerRemote Commander/SRX Controller PictureError Messages 33 GBRear FAN Alert Specifications 35 GBPreset Signals Optional accessoriesPin assignment Displayed image size in multiple screen mode 37 GBLamp Power Lamp Select Lens Control Index