3Com CS/2500 manual EPROM. Each pin must be inserted properly into its socket

Page 78

5-14 CHAPTER 5: MAINTENANCE AND UPGRADES

Replacing EPROMs To replace EPROMs on the motherboard, follow this procedure:

1Remove the cover, as described in “Removing the Cover” on page 5-6. Make sure the server power is off and the power cord is unplugged.

The EPROMs are located on the right side of the motherboard (when viewing the server from the front), as shown in Figure 5-5.

2Gently lift the folded printer ribbon cable to access the EPROMs.

3Note the orientation of the old EPROMs. The notched edge faces the front of the server.

4Note the location of each EPROM in order to replace it correctly.

Figure 5-5 shows the location of the EPROMs. The EPROM covering address lines 0–7 is located in the left socket (when viewed from the front of the server). The EPROM covering address lines 8–F is located in the right socket.

5Using a small slotted screwdriver or an EPROM-pulling tool, carefully pry the old EPROM out of its socket, making sure not to bend the pins.

6Place the old EPROM in the antistatic foam pad.

Keep the old EPROM until the server has been powered up and tested with the new firmware. Refer to Appendix B, “Startup Messages.”

7Remove the new EPROM from its antistatic foam shipping pad.

If the pins have been bent, carefully push the side of the EPROM against a flat antistatic surface so that the pins are at right angles to the body and fit easily into the sockets. Orient the new EPROM in the same way as the old EPROM.

CAUTION: Failure to orient the EPROMs correctly will destroy them when the server is powered on.

8Being careful to line up the pins with the socket, firmly push the new EPROM into its socket until it snaps into place.

CAUTION: Be sure that no pins are bent under the body of the

EPROM. Each pin must be inserted properly into its socket.

9 Replace the cover, as described in the next section.

Image 78
Contents CS/2500 Series 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Iii Page Contents Installation Maintenance and Upgrades PIN Assignments Technical Support Page Figures Tables Audience About this GuideIntroduction ConventionsThis Typeface Italics Italics are used to denote new terms or emphasis About this Guide Overview FeaturesFeatures Ten standard RS-232-D electrical interfacesSoftware CompatibilitySW/2500, can be used only with the CS/2500 and CS/2600 Chassis Panel, see Back Panel onHardware Interrupt Front Panel Its +5 V DC output Power supply module and three types of connectors Back PanelCS/2500 and CS/2600 back panel, shown in -5, contains Overview Back Panel Overview Specifications Optional RackMount Kit VAC Installation Do the following before beginning the installationPreparation Installation Install brackets Cabling the Server To the NetworkTurning on the server All ports are set to terminal SETDefault -TERM DeVice = Installation Slide-lock connection on the server End to the transceiverInstall brackets Configuration, and Appendix C, Monitor Utility ConfigurationAC power source must meet the requirements outlined ModifyingInstallation Startup Guide or software release notes Rbcs files Booting fromDiskette DisketteStartup 3Com Corporation CS/2000 Series Monitor Reading...OK Insert copy and hit return to continue Parameter changes Messages Boot ProblemsNormal Startup Shutting DownShutting Down Startup Configuration EnteringFirmware Monitor Configuration Procedure ChangingFollowing menu is displayed SLP Changing the Configuration Configuration Changing the Configuration SLP, and Trivial File Transfer Protocol Tftp Used with 3Com Network Control Servers NCSs Com no longerNext section Type B Change IP/TFTP Parameters menu appears TftpConfiguration Bootp Emulating a CS/2000 or CS/2100Software and to operate in mixed environments Changing Port Configuration Changing Port Configuration Configuration 3Com recommends the following procedures for preventive Maintenance and UpgradesMaintenance MaintenanceMaintenance and Upgrades Maintenance Reinstall the fuseholder cartridge in the receptacle Upgrades Upgrade procedures require you to remove the server coverRemoving the Server Cover Grasp both sides of the cover and carefully lift it off Rear8-F Pull taut to expose screw Voltages. There are no user-serviceable parts inside Upgrades Remove Connector from Each pin must be inserted properly into its socket EPROM. Each pin must be inserted properly into its socket Replace the cover, as described in the next sectionUpgrades Maintenance and Upgrades Troubleshooting Troubleshooting Operating Problems Troubleshooting Procedures Memory DumpEnter the density of the dump diskettes Return to use the default density 2mb Troubleshooting Figure A-1 Serial Connector Pin Numbering PIN AssignmentsTXD DTE Transceiver DO-S Slct Startup Messages Appendix B Startup Messages You can access the monitor in either of the following ways Monitor UtilitySet the Auto-reboot parameter to Boot monitor Continuous Self-Test and Initial Boot Source parametersNonfunctional Become nonfunctional, enter the following command Memory dumps, refer to Memory Dump Procedures on-2 on page 1-4. The switch is recessed into a round hole to Dump Procedures onSyntax BT Filename and address parameters specify the name Procedures onUsing this menu, refer to , Configuration From memory locationDescription Repeats the previous command Technical Support Services3Com Bulletin Board Service 3ComBBS On-line TechnicalPress Return to see the ThreeComForum main menu Country Telephone Number Hong Kong 852 2537 44 1442 408 727 Appendix D Technical Support Returning Products For RepairSender’s expense To obtain an RMA number, call or fax 10/25/95 Index NumericsCover Index Index Index Index Limited Warranty Bayfront Plaza Santa Clara, CA 408 764-5000 1/1/94